IEC 61557-15:2014
Current
The latest, up-to-date edition.
Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 15: Functional safety requirements for insulation monitoring devices in IT systems and equipment for insulation fault location in IT systems
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
02-12-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Definition of safety functions embedded in
IMDs and IFLSs
5 Requirements on products implementing safety-related
functions
6 Management of functional safety during the development
lifecycle
7 Management of functional safety during the realisation
lifecycle of IMDs and IFLSs
8 Requirements for modifications
9 Proven in use approach
Annex A (informative) - Risk analysis and SIL assignment for
IMDs and IFLSs
Annex B (informative) - Examples for the determination of PFD,
DC and SFF
Annex C (informative) - Failure rate databases
Annex D (informative) - Guide to embedded software design
and development
Annex E (informative) - Information for the assessment of
safety functions
Annex F (informative) - Example of applications
Bibliography
IEC 61557-15:2014 specifies requirements related to functional safety and is based on the IEC 61508 standard series for the realization of Insulation Monitoring Devices (IMD) as specified in IEC 61557-8 and for Insulation Fault Location Systems (IFLS) according to IEC 61557-9, according to phase 10 of the IEC 61508-1 lifecycle. These devices provide safety related functions for IT systems. This part of IEC 61557 is
- concerned only with functional safety requirements intended to reduce the functional risk during the use of IMDs and IFLSs;
- restricted to risks arising directly from the device itself or from several IMDs or IFLSs working together in a system; and
- intended to define the basic safety functions provided by the devices. This part of IEC 61557 does not
- deal with electrical safety according to IEC 61010-1 and the requirements of IEC 61557-8 and IEC 61557-9;
- cover the hazard and risk analysis of a particular use of the IMD or IFLS;
- identify all the safety functions for the application in which the IMD or IFLS is used; and
- cover the IMD or IFLS manufacturing process. Functional safety requirements depend on the application and should be considered as part of the overall risk assessment of the specific application. The supplier of IMDs and IFLSs is not responsible for the application. The application designer is responsible for the risk assessment and for specifying the overall functional safety requirements of the complete IT system and he should select the functional safety level (SIL) of the IMD and/or IFLS when their safety function is part of the functional safety assessment in the IT system.
This publication is to be read in conjunction with IEC 61557-8:2007 and IEC 61557-9:2009
DevelopmentNote |
To be read in conjunction with IEC 61557-8 and IEC 61557-9. Stability date: 2017. (02/2014)
|
DocumentType |
Standard
|
Pages |
154
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
SN EN 61557-15:2014 | Identical |
NF EN 61557-15 : 2014 | Identical |
NBN EN 61557-15 : 2014 | Identical |
NEN EN IEC 61557-15 : 2014 | Identical |
PN EN 61557-15 : 2014 | Identical |
VDE 0413-15 : 2014 | Identical |
DIN EN 61557-15 : 2014 | Identical |
UNE-EN 61557-15:2014 | Identical |
BS EN 61557-15:2014 | Identical |
CEI EN 61557-15 : 2014 | Identical |
EN 61557-15:2014 | Identical |
PNE-FprEN 61557-15 | Identical |
I.S. EN 50628:2016 | ERECTION OF ELECTRICAL INSTALLATIONS IN UNDERGROUND MINES |
BS EN 50628:2016 | Erection of electrical installations in underground mines |
EN 50628:2016 | Erection of electrical installations in underground mines |
IEC GUIDE 109:2012 | Environmental aspects - Inclusion in electrotechnical product standards |
IEC 61025:2006 | Fault tree analysis (FTA) |
IEC 61326-2-4:2012 | Electrical equipment for measurement, control and laboratory use - EMC requirements - Part 2-4: Particular requirements - Test configurations, operational conditions and performance criteria for insulation monitoring devices according to IEC 61557-8 and for equipment for insulation fault location according to IEC 61557-9 |
IEC 60364-7-710:2002 | Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations |
IEC 60319:1999 | Presentation and specification of reliability data for electronic components |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
IEC/ISO 31010:2009 | Risk management - Risk assessment techniques |
IEC 60364-5-53:2001+AMD1:2002+AMD2:2015 CSV | Electrical installations of buildings - Part 5-53: Selection and erection of electrical equipment - Isolation, switching and control |
IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
IEC 61078:2016 | Reliability block diagrams |
IEC 61165:2006 | Application of Markov techniques |
IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC TR 62380:2004 | Reliability data handbook - Universal model for reliability prediction of electronics components, PCBs and equipment |
IEC 61557-1:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 1: General requirements |
IEC 60300-3-1:2003 | Dependability management - Part 3-1: Application guide - Analysis techniques for dependability - Guide on methodology |
IEC 61709:2017 | Electric components - Reliability - Reference conditions for failure rates and stress models for conversion |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 6469-3:2011 | Electrically propelled road vehicles Safety specifications Part 3: Protection of persons against electric shock |
IEC 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508) |
IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
IEC 60364-5-55:2011+AMD1:2012+AMD2:2016 CSV | Electrical installations of buildings - Part 5-55: Selection and erection of electrical equipment - Other equipment |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
IEC 61557-8:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 8: Insulation monitoring devices for IT systems |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
IEC 62280-1:2002 | Railway applications - Communication, signalling and processing systems - Part 1: Safety-related communication in closed transmission systems |
IEC 61800-5-2:2016 | Adjustable speed electrical power drive systems - Part 5-2: Safety requirements - Functional |
IEC 61326-3-1:2017 | Electrical equipment for measurement, control and laboratory use - EMC requirements – Part 3-1: Immunity requirements for safety-related systems and for equipment intended to perform safety-related functions (functional safety) – General industrial applications |
IEC 61784-3:2016+AMD1:2017 CSV | Industrial communication networks - Profiles - Part 3: Functional safety fieldbuses - General rules and profile definitions |
IEC GUIDE 116:2010 | Guidelines for safety related risk assessment and risk reduction for low voltage equipment |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.