IEC 61534-1:2011+AMD1:2014 CSV
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Powertrack systems - Part 1: General requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
07-25-2020
English - French
06-30-2014
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Ratings
7 Classification
8 Marking and documentation
9 Construction
10 Clearances, creepage distances and
solid insulation
11 Protection against electric shock
12 Terminals and terminations
13 Screws, current carrying parts and connections
14 Mechanical strength
15 Insulation resistance test and dielectric
strength test
16 Normal operation
17 Temperature rise
18 Short-circuit protection and short-circuit
withstand strength
19 Resistance to heat
20 Fire hazard
21 External influences
22 Electromagnetic compatibility
Annex A (normative) - Measurement of clearances
and creepage distances
Annex B (normative) - Proof tracking test
Annex C (normative) - Relationship between rated
impulse withstand voltage, rated voltage and
overvoltage category III
Annex D (normative) - Pollution degree
Annex E (informative) - Diagram for the dimensioning of
clearances and creepage distances
Annex F (normative) - Impulse voltage test
Annex G (normative) - Routine test
Bibliography
IEC 61534-1:2011+A1:2014 specifies general requirements and tests for powertrack (PT) systems with a rated voltage not exceeding 277 V a.c. single phase, or 480 V a.c. two or three phase 50 Hz/60 Hz with a rated current not exceeding 63 A. These systems are used for distributing electricity in household, commercial and industrial premises. This second edition cancels and replaces the first edition published in 2003 and constitutes a technical revision. The main changes from the previous edition are as follows:
- updated normative references (Clause 2);
- changes to the number of samples to be tested (Subclause 5.3);
- inclusion of a short circuit test (New Clause 18);
- changes to external influences (Clause 21).
The contents of the corrigendum apply to the French version only. This consolidated version consists of the second edition (2011) and its amendment 1 (2014). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 23/SC 23A
|
DevelopmentNote |
Stability Date: 2020. (11/2017)
|
DocumentType |
Standard
|
Pages |
278
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
SN EN 61534-1:2011 | Identical |
EN 61534-1:2011 | Identical |
GOST R IEC 61534-1 : 2014 | Identical |
NF EN 61534-1 : 2011 AMD 1 2014 | Identical |
NBN EN 61534-1 : 2011 AMD 1 2014 | Identical |
NEN EN IEC 61534-1 : 2011 AMD 1 2014 | Identical |
I.S. EN 61534-1:2011 | Identical |
DIN EN 61534-1 : 2015-03 | Identical |
UNE-EN 61534-1:2011 | Identical |
CEI EN 61534-1 : 2012 | Identical |
EN 61534-1:2011/A1:2014 | Identical |
SN EN 61534-1 : 2003 | Identical |
BS EN 61534-1 : 2011 | Identical |
PN EN 61534-1 : 2011 AMD 1 2015 | Identical |
SAC GB/T 34130.1 : 2017 | Identical |
VDE 0604-100 : 2015-03 | Identical |
BS EN 61534-21:2014 | Powertrack systems Particular requirements for powertrack systems intended for wall and ceiling mounting |
HD 60364-5-54:2011/A11:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
NF EN 61534-22 : 2014 | POWERTRACK SYSTEMS - PART 22: PARTICULAR REQUIREMENTS FOR POWERTRACK SYSTEMS INTENDED FOR ONFLOOR OR UNDERFLOOR INSTALLATION |
BS EN 61534-22:2014 | Powertrack systems Particular requirements for powertrack systems intended for onfloor or underfloor installation |
I.S. EN 61534-22:2014 | POWERTRACK SYSTEMS - PART 22: PARTICULAR REQUIREMENTS FOR POWERTRACK SYSTEMS INTENDED FOR ONFLOOR OR UNDERFLOOR INSTALLATION |
I.S. EN 61534-21:2014 | POWERTRACK SYSTEMS - PART 21: PARTICULAR REQUIREMENTS FOR POWERTRACK SYSTEMS INTENDED FOR WALL AND CEILING MOUNTING |
12/30271836 DC : 0 | BS EN 61534-22 - POWERTRACK SYSTEMS - PART 22: PARTICULAR REQUIREMENTS FOR POWERTRACK SYSTEMS INTENDED FOR ON FLOOR OR UNDER FLOOR INSTALLATION |
HD 62640:2015/A11:2016 | RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES (IEC 62640:2011, MODIFIED) |
IEC 61534-22:2014 | Powertrack systems - Part 22: Particular requirements for powertrack systems intended for onfloor or underfloor installation |
CEI EN 61534-21 : 2015 | POWERTRACK SYSTEMS - PART 21: PARTICULAR REQUIREMENTS FOR POWERTRACK SYSTEMS INTENDED FOR WALL AND CEILING MOUNTING |
I.S. HD 60364-5-54:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
S.R. HD 60364-5-54:2011 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-54: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS |
IEC 60364-5-54:2011 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 62640:2011+AMD1:2015 CSV | Residual current devices with or without overcurrent protection forsocket-outlets for household and similar uses |
EN 61534-21:2014 | Powertrack systems - Part 21: Particular requirements for powertrack systems intended for wall and ceiling mounting |
EN 61534-22:2014 | Powertrack systems - Part 22: Particular requirements for powertrack systems intended for onfloor or underfloor installation |
UNE-HD 62640:2016 | Residual current devices with or without overcurrent protection for socket-outlets for household and similar uses |
IEC 61534-21:2014 | Powertrack systems - Part 21: Particular requirements for powertrack systems intended for wall and ceiling mounting |
UNE-EN 61534-21:2015 | Powertrack systems - Part 21: Particular requirements for powertrack systems intended for wall and ceiling mounting |
UNE-EN 61534-22:2015 | Powertrack systems - Part 22: Particular requirements for powertrack systems intended for onfloor or underfloor installation |
PRHD 62640 : DRAFT 2014 | RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES (IEC 62640:2011, MODIFIED) |
I.S. HD 62640:2015 | RESIDUAL CURRENT DEVICES WITH OR WITHOUT OVERCURRENT PROTECTION FOR SOCKET-OUTLETS FOR HOUSEHOLD AND SIMILAR USES |
UNE-HD 60364-5-54:2015 | Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60038:2009 | IEC standard voltages |
IEC 60998-1:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 1: General requirements |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 60998-2-3:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-3: Particular requirements for connecting devices as separate entities with insulation-piercing clamping units |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 60884-1:2002+AMD1:2006+AMD2:2013 CSV | Plugs and socket-outlets for household and similar purposes - Part1: General requirements |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60439-2:2000+AMD1:2005 CSV | Low-voltage switchgear and controlgear assemblies - Part 2: Particular requirements for busbar trunking systems (busways) |
IEC 60999-2:2003 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 2: Particular requirements for clamping units for conductors above 35 mm2 up to 300 mm2 (included) |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60570:2003+AMD1:2017 CSV | Electrical supply track systems for luminaires |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 60127-1:2006+AMD1:2011+AMD2:2015 CSV | Miniature fuses - Part 1: Definitions for miniature fuses andgeneral requirements for miniature fuse-links |
IEC 60695-11-2:2017 | Fire hazard testing - Part 11-2: Test flames - 1 kW pre-mixed flame - Apparatus, confirmatory test arrangement and guidance |
ISO 2081:2008 | Metallic and other inorganic coatings Electroplated coatings of zinc with supplementary treatments on iron or steel |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
ISO 1456:2009 | Metallic and other inorganic coatings — Electrodeposited coatings of nickel, nickel plus chromium, copper plus nickel and of copper plus nickel plus chromium |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
ISO 2093:1986 | Electroplated coatings of tin — Specification and test methods |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60695-10-2:2014 | Fire hazard testing - Part 10-2: Abnormal heat - Ball pressure test method |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.