IEC 61223-2-9:1999
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Evaluation and routine testing in medical imaging departments - Part 2-9: Constancy tests - Equipment for indirect radioscopy and indirect radiography
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
09-09-2010
English
09-16-1999
Foreword
1 Scope and object
1.1 Scope
1.2 Object
2 Normative references
3 Terminology
3.1 Degree of requirements
3.2 Use of terms
4 General aspects of CONSTANCY TESTS
4.1 General conditions affecting test
procedures
4.2 Establishment of BASELINE VALUES
4.3 Frequency of CONSTANCY TESTS
4.4 Identification of equipment,
instrumentation and test conditions
4.5 Measured functional parameters
5 Performance tests
5.1 RADIATION output from the X-RAY SOURCE
ASSEMBLY
5.2 Grey-scale image and AUTOMATIC INTENSITY
CONTROL
5.3 Threshold contrast for detail of large
size
5.4 Limiting resolution for detail of high
contract for X-RADIATION
5.5 Frequency of CONSTANCY TESTS
6 Statement of compliance
Annex A (normative) Terminology - Index of defined terms
Annex B (informative) Example of a form for the
standardized test report
Annex C (informative) Guidance on action to be taken
Annex D (normative) PHANTOMS AND TEST DEVICES
Applies to those components of X-ray equipment which a) generate, influence the propagation of, and detect X-radiation, and b) process, present and store diagnostic X-ray images in radiological installations with diagnostic X-ray systems for indirect radioscopy and indirect radiography which use X-ray image intensifiers in conjunction with analogue and/or digital storage systems: - closed-circuit television display system - cut films cameras - cine cameras. This standard defines - the essential parameters which describe or affect the performance of the above components of X-ray equipment, and - methods of checking that variations in measured quantities related to those parameters are within acceptable limits, in order to maintain adequate standards of imaging whilst reducing unnecessary irradiation of the patient.
DocumentType |
Standard
|
Pages |
21
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
CEI 62-113 : 2001 | Identical |
BS IEC 61223-2.9 : 1999 | Identical |
AS/NZS 4184.2.9:2002 | Identical |
NEN IEC 61223-2-9 : 1999 | Identical |
JIS Z 4752-2-9:2008 | Identical |
GOST R IEC 61223-2-9 : 2001 | Identical |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
PD IEC TR 60788:2004 | Medical electrical equipment. Glossary of defined terms |
BS EN 61223-3-1:1999 | Evaluation and routine testing in medical imaging departments Acceptance tests - Imaging performance of X-ray equipment for radiographic and radiscopic systems |
IEC TR 60788:2004 | Medical electrical equipment - Glossary of defined terms |
IEC 61223-2-4:1994 | Evaluation and routine testing in medical imaging departments - Part 2-4: Constancy tests - Hard copy cameras |
IEC 61223-2-5:1994 | Evaluation and routine testing in medical imaging departments - Part 2-5: Constancy tests - Image display devices |