IEC 61166:1993
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
11-15-2006
English - French, Spanish, Castilian
04-07-1993
Foreword
Clause
1 Scope and object
2 Normative references
3 Definitions
4 Seismic qualification requirements
5 Severities
6 Qualification by test
6.1 Introduction
6.2 Mounting
6.3 External load
6.4 Measurement
6.5 Frequency range
6.6 Test severity
6.6.1 Parameters for sine-beat excitation
6.6.2 Parameters for time-history excitation
6.7 Testing
6.7.1 Test directions
6.7.2 Test sequence
7 Qualification by combined test and analysis
7.1 Introduction
7.2 Vibrational and functional data
7.3 Analysis
7.3.1 Acceleration time-history method of
calculation
7.3.2 Modal analysis using the required response
spectrum (RRS)
7.3.3 Static coefficient analysis
8 Evaluation of the seismic qualification
8.1 Combination of stresses
8.2 Acceptance criteria of the seismic simulation
8.3 Functional evaluation of the test results
9 Documentation
9.1 Information for seismic qualification
9.2 Test report
9.3 Analysis report
Figures
Annex
A Characterization of the equipment
Specifies seismic severity levels and gives a choice of methods that can be applied to demonstrate the performance of HV circuit-breakers for which seismic qualification is required.
DevelopmentNote |
Also numbered as BS EN 61166 (11/2005)
|
DocumentType |
Standard
|
Pages |
31
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NF EN 61166 : 1993 | Identical |
NEN 11166 : 1994 | Identical |
I.S. EN 61166:1996 | Identical |
PN EN 61166 : 2002 | Identical |
SN EN 61166 : 1993 | Identical |
VDE 0670-111 : 1994 | Identical |
DIN EN 61166 : 1994 | Identical |
UNE-EN 61166:1997 | Identical |
CEI EN 61166 : 2013 | Identical |
EN 61166:1993 | Identical |
CEI EN 61462 : 2008 | COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS |
CSA C62155 : 2006 : R2015 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
I.S. EN 60044-8:2002 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
CSA C60044-8 : 2007 : R2016 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
I.S. EN 60694:1999 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
IEC PAS 62271-109:2002 | High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
BS EN 61462:2007 | Composite hollow insulators. Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1000 V. Definitions, test methods, acceptance criteria and design recommendations |
BS EN 45510-2-7:2002 | Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear |
94/712993 DC : DRAFT NOV 1994 | PREN 45511 - GUIDE FOR PROCUREMENT - ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
I.S. EN 61462:2007 | COMPOSITE HOLLOW INSULATORS - PRESSURIZED AND UNPRESSURIZED INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGE GREATER THAN 1 000 V - DEFINITIONS, TEST METHODS, ACCEPTANCE CRITERIA AND DESIGN RECOMMENDATIONS |
CEI EN 62155 : 2004 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
NF EN 62155 : 2003 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
CSA C62155:2006 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
CEI UNI EN 45510-2-7 : 2006 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
04/30111859 DC : 0 | IEC 62271-1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROL GEAR - PART 1: COMMON SPECIFICATIONS |
CSA C60044-8 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
BS EN 60044-8:2002 | Instrument transformers Electronic current transformers |
IEC 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
NF EN 60044-8 : 2006 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSDUCERS |
CSA C60044-8 :2007 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
IEC 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1 000 V |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
11/30242675 DC : 0 | BS EN 60099-4 F2 - SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS |
CEI EN 60044-8 : 2004 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS |
BS EN 62155:2003 | Hollow pressurized and unpressurized ceramic and glass insulators for use in electrical equipment with rated voltages greater than 1000 V |
UNI CEI EN 45510-2-7 : 2011 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
BS EN 61264:1999 | Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
I.S. EN 62155:2003 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
EN 61462:2007 | Composite hollow insulators - Pressurized and unpressurized insulators for use in electrical equipment with rated voltage greater than 1 000 V - Definitions, test methods, acceptance criteria and design recommendations |
EN 45510-2-7:2002 | Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear |
BS EN 60694:1997 | Common specifications for high-voltage switchgear and controlgear standards |
04/30112476 DC : DRAFT APR 2004 | |
CSA C62155 : 2006 : R2011 | HOLLOW PRESSURIZED AND UNPRESSURIZED CERAMIC AND GLASS INSULATORS FOR USE IN ELECTRICAL EQUIPMENT WITH RATED VOLTAGES GREATER THAN 1000 V |
IEC 61264:1998 | Ceramic pressurized hollow insulators for high-voltage switchgear and controlgear |
EN 61264:1998/corrigendum:2000 | CERAMIC PRESSURIZED HOLLOW INSULATORS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60068-2-57:2013 | Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method |
IEC 60056:1987 | High-voltage alternating-current circuit-breakers |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.