IEC 61156-3:2008
Current
The latest, up-to-date edition.
Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
11-13-2008
FOREWORD
1 General
1.1 Scope
1.2 Normative references
1.3 Installation considerations
2 Definitions, materials and cable construction
2.1 Definitions
2.2 Materials and cable construction
2.2.1 General remarks
2.2.2 Cable construction
2.2.3 Conductor
2.2.4 Insulation
2.2.5 Colour code of insulation
2.2.6 Cable element
2.2.7 Screening of the cable element
2.2.8 Cable make-up
2.2.9 Screening of the cable core
2.2.10 Sheath
2.2.11 Colour of sheath
2.2.12 Identification
2.2.13 Finished cable
3 Characteristics and requirements
3.1 General remarks
3.2 Electrical characteristics
3.2.1 Conductor resistance
3.2.2 Resistance unbalance
3.2.3 Dielectric strength
3.2.4 Insulation resistance
3.2.5 Mutual capacitance
3.2.6 Capacitance unbalance
3.2.7 Transfer impedance
3.3 Transmission characteristics
3.3.1 Velocity of propagation (phase velocity)
3.3.2 Attenuation
3.3.3 Unbalance attenuation
3.3.4 Near-end crosstalk (NEXT)
3.3.5 Characteristic impedance
3.3.6 Structural Return Loss (SRL)
3.4 Mechanical and dimensional characteristics
and requirements
3.4.1 Dimensional requirements
3.4.2 Elongation at break of the conductors
3.4.3 Elongation at break of the insulation
3.4.4 Elongation at break of the sheath
3.4.5 Tensile strength of the sheath
3.4.6 Crush test of the cable
3.4.7 Impact test of the cable
3.4.8 Repeated bending of the cable
3.4.9 Tensile performance of the cable
3.5 Environmental characteristics
3.5.1 Shrinkage of insulation
3.5.2 Wrapping test of insulation after thermal ageing
3.5.3 Bending test of insulation at low temperature
3.5.4 Elongation at break of the sheath after ageing
3.5.5 Tensile strength of the sheath after ageing
3.5.6 Sheath pressure test at high temperature
3.5.7 Cold bend test of the cable
3.5.8 Heat shock test
3.5.9 Flame propagation characteristics of a single
cable
3.5.10 Flame propagation characteristics of bunched
cables
3.5.11 Acid gas evolution
3.5.12 Smoke generation
3.5.13 Toxic gas emission
3.5.14 Combined flame and smoke test for cables
in environmental air handling space
4 Introduction to the blank detail specification
IEC 61156-3:2008(E) defines individually screened, common overall core screen and unscreened pairs or quads in cables for work area wiring. These cables are suitable for the various communication systems for which the reference is given in the relevant detail specification. The cables covered by this sectional specification are intended to operate with voltages and currents normally adopted for communication systems. These cables should not be connected to low impedance sources, for example, the public mains electricity supply. The cables are specifically intended for work area wiring as defined in ISO/IEC 11801. This third edition cancels and replaces the second edition published in 2003. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition:
a) new requirements for new cables Cat3, and Cat5 applications;
b) a better numbering in order to take into account the generic specification.
Committee |
TC 46/SC 46C
|
DevelopmentNote |
To be used in conjunction with IEC 61156-1. (04/2003) Stability Date: 2017. (10/2012)
|
DocumentType |
Standard
|
Pages |
14
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN 11156-3 : 1995 | Identical |
NEN IEC 61156-3 : 2003 | Identical |
BS EN 50289-4-2:2001 | Identical |
BS EN 61076-3-115:2010 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 12 related to IEC 61076-3-106. Push-pull type |
06/30146603 DC : DRAFT JULY 2006 | IEC 61935-1 ED3 - TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH ISO/IEC 11801 - PART 1 - INSTALLED CABLING |
IEC 61156-3-2:2001 | Multicore and symmetrical pair/quad cables for digital communications - Part 3-2: Work area wiring - Capability Approval - Sectional specification |
NF EN 61076-3-114 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-114: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 11 RELATED TO IEC 61076-3-106 - BAYONET COUPLING TYPE |
CSA ISO/IEC 15018 : 2005 : R2010 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018:2005 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R201000 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
I.S. EN 61076-3-115:2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
CEI EN 61076-3-106 : 2007 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-106: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE |
IEC PAS 61076-3-117:2006 | Connectors for electronic equipment - Product requirements - Part 3-117: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating IEC 60603-7 - Variant 14 related to IEC 61076-3-106 - Push-pull coupling |
IEC PAS 61076-3-116:2005 | Connectors for electronic equipment - Part 3-116: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 13 related to IEC 61076-3-106 - Bayonet coupling with spring clamp |
EN 61076-3-114 : 2009 | Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type |
EN 61076-3-116 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
CEI EN 61935-1 : 2010 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
06/30152213 DC : DRAFT JUNE 2006 | BS EN 60603-7-1 ED. 2 - CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-1: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS |
CEI EN 61076-3-116 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - PROTECTIVE HOUSINGS FOR USE WITH 8- WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
BS EN 61076-3-116:2008 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 13 related to IEC 61076-3-106. Locking lever |
IEC 61156-3-1:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 3-1: Work area wiring - Blank detail specification |
I.S. EN 61076-3-106:2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-106: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE |
IEC 61156-1-1:2001 | Multicore and symmetrical pair/quad cables for digital communications - Part 1-1: Capability Approval - Generic specification |
EN 60603-7:2009/A1:2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008/A1:2011) |
BS EN 61076-3-114:2009 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for.protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface. Variant 11 related to IEC 61076-3-106. Bayonet coupling type |
CEI EN 61076-3-115 : 2012 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
NF EN 60603-7-3 : DEC 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-3: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 100 MHZ |
NF EN 61076-3-116 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
I.S. EN 61076-3-104:2017 | CONNECTORS FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-104: DETAIL SPECIFICATION FOR 8-WAY, SHIELDED FREE AND FIXED CONNECTORS FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 2000 MHZ |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
IEC 61076-3-104:2017 | Connectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
NF EN 60603-7 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS |
04/30079682 DC : DRAFT AUG 2004 | IEC 61935-1 ED 2 - TESTING OF BALANCED COMMUNICATION CABLING IN ACCORDANCE WITH ISO/IEC 11801 - PART 1: INSTALLED CABLING |
16/30325971 DC : 0 | BS ISO/IEC 11801-1 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 1: GENERAL REQUIREMENTS |
NF EN 60603-7-4 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7-4: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS, FOR DATA TRANSMISSIONS WITH FREQUENCIES UP TO 250 MHZ |
IEC PAS 61076-3-114:2005 | Connectors for electronic equipment - Part 3-114: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type |
BS EN 61935-1:2009 | Specification for the testing of balanced and coaxial information technology cabling Installed balanced cabling as specified in the standards series EN 50173 |
I.S. EN 60603-7:2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS (IEC 60603-7:2008) |
IEC PAS 61076-3-115:2005 | Connectors for electronic equipment - Part 3-115: Rectangular connectors - Protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type |
IEC 61076-3-116:2008 | Connectors for electronic equipment - Product requirements - Part 3-116: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 13 related to IEC 61076-3-106 - Locking lever |
IEC 61076-3-114:2009 | Connectors for electronic equipment - Product requirements - Part 3-114: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 11 related to IEC 61076-3-106 - Bayonet coupling type |
IEC 61076-3-106:2006 | Connectors for electronic equipment - Product requirements - Part 3-106: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface |
BS EN 61076-3-106:2006 | Connectors for electronic equipment. Product requirements Rectangular connectors. Detail specification for protective housings for use with 8-way shielded and unshielded connectors for industrial environments incorporating the IEC 60603-7 series interface |
BS EN 60603-7 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PART 7: DETAIL SPECIFICATION FOR 8-WAY, UNSHIELDED, FREE AND FIXED CONNECTORS |
I.S. EN 61076-3-114:2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-114: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 11 RELATED TO IEC 61076-3-106 - BAYONET COUPLING TYPE |
BS EN 61076-3-104:2017 | Connectors for electrical and electronic equipment. Product requirements Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R2015 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
I.S. EN 61076-3-116:2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-116: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 13 RELATED TO IEC 61076-3-106 - LOCKING LEVER |
ISO/IEC 11801-1:2017 | Information technology — Generic cabling for customer premises — Part 1: General requirements |
NF EN 61076-3-115 : 2011 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-115: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR FREQUENCIES UP TO 600 MHZ FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE - VARIANT 12 RELATED TO IEC 61076-3-106 - PUSH-PULL TYPE |
I.S. EN 61935-1:2009 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
EN 61076-3-104:2017 | Connectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz |
IEC 61076-3-115:2009 | Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type |
EN 61076-3-115:2010 | Connectors for electronic equipment - Product requirements - Part 3-115: Rectangular connectors - Detail specification for protective housings for use with 8-way shielded and unshielded connectors for frequencies up to 600 MHz for industrial environments incorporating the IEC 60603-7 series interface - Variant 12 related to IEC 61076-3-106 - Push-pull type |
EN 61935-1:2009 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
EN 61076-3-106 : 2006 | CONNECTORS FOR ELECTRONIC EQUIPMENT - PRODUCT REQUIREMENTS - PART 3-106: RECTANGULAR CONNECTORS - DETAIL SPECIFICATION FOR PROTECTIVE HOUSINGS FOR USE WITH 8-WAY SHIELDED AND UNSHIELDED CONNECTORS FOR INDUSTRIAL ENVIRONMENTS INCORPORATING THE IEC 60603-7 SERIES INTERFACE |
IEC 60304:1982 | Standard colours for insulation for low-frequency cables and wires |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
IEC TR 60344:2007 | Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide |
IEC 61156-1:2007+AMD1:2009 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 1: Generic specification |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-