IEC 61076-3-104:2017
Current
The latest, up-to-date edition.
Connectors for electrical and electronic equipment - Product requirements - Part 3-104: Detail specification for 8-way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, English
05-22-2017
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Technical information
4 Dimensional information
5 Characteristics
6 Test schedule
Annex A (normative) - Gauging procedure
Annex B (normative) - Locking device mechanical
operation - test procedure and requirements
Annex C (normative) - Plug and outlet interoperability
qualification
Annex D (normative) - General requirements for the
measurement set-up
Annex E (normative) - Insertion loss
Annex F (normative) - Return loss
Annex G (normative) - Near end cross talk (NEXT)
Annex H (normative) - Far end cross talk (FEXT)
Annex I (normative) - Transverse Conversion Loss
(TCL) and Transverse Conversion Transfer
Loss (TCTL)
Annex J (normative) - Termination of balun
Bibliography
IEC 61076-3-104:2017 establishes uniform specifications, type testing requirements for 8 way, shielded free and fixed connectors for data transmissions with frequencies up to 2 000 MHz, and used as category 7A connectors in class FA cabling systems specified in ISO/IEC 11801-1. It contains all test methods and sequences, severity and preferred values for dimensions and characteristics.
This third edition of IEC 61076-3-104 cancels and replaces the second edition, published in 2006, and constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
- the title has been changed to incorporate transmissions with frequencies up to 2 000 MHz;
- the drawings of some styles have been corrected for clarification;
- Figures 23 and 24 have been updated;
- Figure 3 has been updated to include reference dimensions and dimensional format changes;
- the dimensions of Figure 7 have been updated;
- the type designation and ordering information has been removed for consistency with the most updated sectional specification;
- the test schedule was updated to include appropriate IEC 60512 Test Nos;
- the electrical performance requirements have been revised for 2 GHz level and interchangeability information has been added for performance categories.
Committee |
TC 48/SC 48B
|
DevelopmentNote |
Supersedes IEC PAS 61076-3-104 (04/2003) Stability Date: 2019. (05/2017)
|
DocumentType |
Standard
|
ISBN |
978-2-8322-8534-3
|
Pages |
167
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
UNE-EN 61076-3-104:2006 | Identical |
EN 61076-3-104:2017 | Identical |
DIN EN 61076-3-104 : 2018 | Identical |
UNE-EN 61076-3-104:2017 | Identical |
BS EN 61076-3-104:2017 | Identical |
DIN EN 61076-3-104 : 2007 | Identical |
NEN EN IEC 61076-3-104 : 2017 | Identical |
CEI EN 61076-3-104 : 2007 | Identical |
PN EN 61076-3-104 : 2017 | Identical |
SN EN 61076-3-104 : 2003 | Identical |
NF EN 61076 3 104 : 2013 | Identical |
PNE-FprEN 61076-3-104:2016 | Identical |
VDE 0687-76-3-104 : 2018 | Identical |
CEI EN 61935-2 : 2011 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 2: CORDS AS SPECIFIED IN ISO/IEC 11801 AND RELATED STANDARDS |
BS ISO/IEC 11801-1:2017 | Information technology. Generic cabling for customer premises General requirements |
I.S. EN 60512-25-9:2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
I.S. EN 50173-4:2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
CSA ISO/IEC 15018 : 2005 : R2010 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018:2005 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R201000 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
CEI EN 61375-3-4 : 2014 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-4: ETHERNET CONSIST NETWORK (ECN) |
EN 61935-2:2010 | Specification for the testing of balanced and coaxial information technology cabling - Part 2: Cords as specified in ISO/IEC 11801 and related standards |
EN 60512-25-9 : 2008 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
DEFSTAN 21-88(PT4)/4(2012) : 2012 | POLICIES AND PROCEDURES FOR SYSTEM INTEGRATION IN SURFACE SHIPS - PART 4: LEGACY PLATFORM DEDICATED INTERFACES |
DEFSTAN 21-88/2(2006) : 2006 | POLICIES AND PROCEDURES FOR COMBAT SYSTEM INTEGRATION IN SURFACE SHIPS (SSP 88) |
NF EN 61935-1 : 2010 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
16/30325955 DC : 0 | BS ISO/IEC 11801-5 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 5: DATA CENTRES |
PD ISO/IEC TR 29125:2010 | Information technology. Telecommunications cabling requirements for remote powering of terminal equipment |
CEI EN 61935-1 : 2010 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
CLC/TR 50173-99-3:2012 | Information technology - Generic cabling systems - Part 99-3: Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications |
I.S. EN 60512-28-100:2013 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 28-100: SIGNAL INTEGRITY TESTS UP TO 1000 MHZ ON IEC 60603-7 AND IEC 61076-3 SERIES CONNECTORS - TESTS 28A TO 28G (IEC 60512-28-100:2013(EQV)) |
EN 50173-5 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 5: DATA CENTRES |
I.S. EN 50173-2:2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 2: OFFICE PREMISES |
I.S. EN 61935-2:2010 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 2: CORDS AS SPECIFIED IN ISO/IEC 11801 AND RELATED STANDARDS |
ISO/IEC TR 29125:2010 | Information technology Telecommunications cabling requirements for remote powering of terminal equipment |
I.S. EN 50173-3:2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
EN 50173-4 : 2007 AMD 2 2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
NF EN 50173-4 : 2010 AMD 2 2013 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
IEC 61375-3-4:2014 | Electronic railway equipment - Train communication network (TCN) - Part 3-4: Ethernet Consist Network (ECN) |
CEI CLC/TR 50173-99-3 : 2013 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 99-3: HOME CABLING INFRASTRUCTURES UP TO 50 M IN LENGTH TO SUPPORT SIMULTANEOUS AND NON SIMULTANEOUS PROVISION OF APPLICATIONS |
16/30325974 DC : 0 | BS ISO/IEC 11801-2 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 2: OFFICE PREMISES |
BS EN 61375-3-4 : 2014 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-4: ETHERNET CONSIST NETWORK (ECN) (IEC 61375-3-4:2014) |
I.S. EN 50173-1:2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
ISO/IEC 14165-114:2005 | Information technology Fibre Channel Part 114: 100 MB/s Balanced copper physical interface (FC-100-DF-EL-S) |
CSA ISO/IEC 14165-114: 2006 | INFORMATION TECHNOLOGY - FIBRE CHANNEL - PART 114: 100 MB/S BALANCED COPPER PHYSICAL INTERFACE (FC-100-DF-EL-S) |
CEI EN 50173-1 : 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
S.R. CLC/TR 50173-99-3:2012 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 99-3: HOME CABLING INFRASTRUCTURES UP TO 50 M IN LENGTH TO SUPPORT SIMULTANEOUS AND NON SIMULTANEOUS PROVISION OF APPLICATIONS |
BS EN 50173-2 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 2: OFFICE PREMISES |
BS EN 50173-1:2011 | Information technology. Generic cabling systems General requirements |
NF EN 50173-1 : 2017 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 1: GENERAL REQUIREMENTS |
EN 50173-1:2011 | Information technology - Generic cabling systems - Part 1: General requirements |
ISO/IEC 11801:2002 | Information technology Generic cabling for customer premises |
ISO/IEC 15018:2004 | Information technology Generic cabling for homes |
EN 60512-28-100:2013 | Connectors for electronic equipment - Tests and measurements - Part 28-100: Signal integrity tests up to 1 000 MHz on IEC 60603-7 and IEC 61076-3 series connectors - Tests 28a to 28g |
CEI EN 60512-25-9 : 2010 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
EN 50173-3 : 2007 COR 2011 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
CEI EN 60512-28-100 : 2014 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 28-100: SIGNAL INTEGRITY TESTS UP TO 1000 MHZ ON 60603-7 AND 61076-3 SERIES CONNECTORS - TESTS 28A TO 28G |
ISO/IEC TS 29125:2017 | Information technology — Telecommunications cabling requirements for remote powering of terminal equipment |
PD CLC/TR 50173-99-3:2012 | Information technology. Generic cabling systems Home cabling infrastructures up to 50 m in length to support simultaneous and non simultaneous provision of applications |
16/30325971 DC : 0 | BS ISO/IEC 11801-1 - INFORMATION TECHNOLOGY - GENERIC CABLING FOR CUSTOMER PREMISES - PART 1: GENERAL REQUIREMENTS |
ISO/IEC 11801-5:2017 | Information technology Generic cabling for customer premises Part 5: Data centres |
BS EN 61935-1:2009 | Specification for the testing of balanced and coaxial information technology cabling Installed balanced cabling as specified in the standards series EN 50173 |
CAN/CSA-ISO/IEC 14165-114:2006(R2016) | INFORMATION TECHNOLOGY - FIBRE CHANNEL - PART 114: 100 MB/S BALANCED COPPER PHYSICAL INTERFACE (FC-100-DF-EL-S) |
I.S. EN 50173-5:2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 5: DATA CENTRES |
BS EN 61935-2:2010 | Specification for the testing of balanced and coaxial information technology cabling Cords as specified in ISO/IEC 11801 and related standards |
I.S. EN 61375-3-4:2014 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-4: ETHERNET CONSIST NETWORK (ECN) |
ISO/IEC 24740:2008 | Information technology Responsive Link (RL) |
IEC 61935-2:2010 | Specification for the testing of balanced and coaxial information technology cabling - Part 2: Cords as specified in ISO/IEC 11801 and related standards |
IEC 60512-25-9:2008 | Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk |
BS EN 60512-25-9:2008 | Connectors for electronic equipment. Tests and measurements Signal integrity tests. Test 25i. Alien crosstalk |
BS EN 60512-28-100:2013 | Connectors for electronic equipment. Tests and measurements Signal integrity tests up to 1000 MHz on IEC 60603-7 and IEC 61076-3 series connectors. Tests 28a to 28g |
BS EN 50173-5 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 5: DATA CENTRES |
BS ISO/IEC 11801-2:2017 | Information technology. Generic cabling for customer premises Office premises |
NF EN 60512-25-9 : 2009 | CONNECTORS FOR ELECTRONIC EQUIPMENT - TESTS AND MEASUREMENTS - PART 25-9: SIGNAL INTEGRITY TESTS - TEST 25I: ALIEN CROSSTALK |
ISO/IEC 11801-1:2017 | Information technology — Generic cabling for customer premises — Part 1: General requirements |
IEC 61935-1:2015 | Specification for the testing of balanced and coaxial information technology cabling - Part 1: Installed balanced cabling as specified in ISO/IEC 11801 and related standards |
BS EN 50173-3 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 3: INDUSTRIAL PREMISES |
BS ISO/IEC 11801-5:2017 | Information technology. Generic cabling for customer premises Data centres |
ISO/IEC 11801-2:2017 | Information technology Generic cabling for customer premises Part 2: Office premises |
CSA ISO/IEC 15018 : 2005 : INC : AMD 1 : 2010 : R2015 | INFORMATION TECHNOLOGY - GENERIC CABLING FOR HOMES |
BS EN 50173-4 : 2007 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS - PART 4: HOMES |
I.S. EN 61935-1:2009 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
EN 61375-3-4:2014/A11:2017 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-4: ETHERNET CONSIST NETWORK (ECN) |
EN 61935-1:2009 | SPECIFICATION FOR THE TESTING OF BALANCED AND COAXIAL INFORMATION TECHNOLOGY CABLING - PART 1: INSTALLED BALANCED CABLING AS SPECIFIED IN THE STANDARDS SERIES EN 50173 |
CSA ISO/IEC 24740 : 2008 | INFORMATION TECHNOLOGY - RESPONSIVE LINK (RL) |
CSA ISO/IEC 24740 : 2008 : R2013 | INFORMATION TECHNOLOGY - RESPONSIVE LINK (RL) |
IEC 61076-1:2006 | Connectors for electronic equipment - Product requirements - Part 1: Generic specification |
IEC 60352-3:1993 | Solderless connections - Part 3: Solderless accessible insulation displacement connections - General requirements, test methods and practical guidance |
IEC 60512-11-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 11-4: Climatic tests - Test 11d: Rapid change of temperature |
IEC 60352-6:1997 | Solderless connections - Part 6: Insulation piercing connections - General requirements, test methods and practical guidance |
IEC 60512-3-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 3-1: Insulation tests - Test 3a: Insulation resistance |
IEC 61076-3:2008 | Connectors for electronic equipment - Product requirements - Part 3: Rectangular connectors - Sectional specification |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 62153-4-12:2009 | Metallic communication cable test methods - Part 4-12: Electromagnetic compatibility (EMC) - Coupling attenuation or screening attenuation of connecting hardware - Absorbing clamp method |
IEC 60512-9-2:2011 | Connectors for electronic equipment - Tests and measurements - Part 9-2: Endurance tests - Test 9b: Electrical load and temperature |
IEC 61156-9:2016 | Multicore and symmetrical pair/quad cables for digital communications - Part 9: Cables for channels with transmission characteristics up to 2 GHz - Sectional specification |
IEC 61156-10:2016 | Multicore and symmetrical pair/quad cables for digital communications - Part 10: Cables for cords with transmission characteristics up to 2 GHz - Sectional specification |
IEC 60512-13-2:2006 | Connectors for electronic equipment - Tests and measurements - Part 13-2: Mechanical operation tests - Test 13b: Insertion and withdrawal forces |
IEC 60512-2-5:2003 | Connectors for electronic equipment - Tests and measurements - Part 2-5: Electrical continuity and contact resistance tests - Test 2e: Contact disturbance |
IEC 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
ISO 1302:2002 | Geometrical Product Specifications (GPS) Indication of surface texture in technical product documentation |
IEC 60512-26-100:2008+AMD1:2011 CSV | Connectors for electronic equipment - Tests and measurements - Part 26-100: Measurement setup, test and reference arrangements and measurements for connectors according to IEC 60603-7 - Tests 26a to 26g |
IEC 61156-2:2010 | Multicore and symmetrical pair/quad cables for digital communications - Part 2: Symmetrical pair/quad cables with transmission characteristics up to 100 MHz - Horizontal floor wiring - Sectional specification |
AS 11801.2:2019 | Information technology - Generic cabling for customer premises Office premises (ISO/IEC 11801-2:2017, MOD) |
IEC 60603-7:2008+AMD1:2011 CSV | Connectors for electronic equipment - Part 7: Detail specification for 8-way, unshielded, free and fixed connectors |
IEC 60512-1-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-1: General examination - Test 1a: Visual examination |
IEC 60352-5:2012 | Solderless connections - Part 5: Press-in connections - General requirements, test methods and practical guidance |
IEC 60512-2-1:2002 | Connectors for electronic equipment - Tests and measurements - Part 2-1: Electrical continuity and contact resistance tests - Test 2a: Contact resistance - Millivolt level method |
IEC 60512-9-1:2010 | Connectors for electronic equipment - Tests and measurements - Part 9-1: Endurance tests - Test 9a: Mechanical operation |
IEC 60512-11-7:2003 | Connectors for electronic equipment - Tests and measurements - Part 11-7: Climatic tests - Test 11g: Flowing mixed gas corrosion test |
IEC 61156-7:2003+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 7: Symmetrical pair cables with transmissioncharacteristics up to 1 200 MHz - Sectional specification fordigital and analog communication cables |
IEC 60512-4-1:2003 | Connectors for electronic equipment - Tests and measurements - Part 4-1: Voltage stress tests - Test 4a: Voltage proof |
IEC 61156-6:2010+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 6: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Work area wiring -Sectional specification |
IEC 60352-2:2006+AMD1:2013 CSV | Solderless connections - Part 2: Crimped connections - Generalrequirements, test methods and practical guidance |
IEC 61156-5:2009+AMD1:2012 CSV | Multicore and symmetrical pair/quad cables for digital communications - Part 5: Symmetrical pair/quad cables withtransmission characteristics up to 1 000 MHz - Horizontal floorwiring - Sectional specification |
IEC 61156-4:2009 | Multicore and symmetrical pair/quad cables for digital communications - Part 4: Riser cables - Sectional specification |
IEC 61156-3:2008 | Multicore and symmetrical pair/quad cables for digital communications - Part 3: Work area cable - Sectional specification |
IEC 60512-6-4:2002 | Connectors for electronic equipment - Tests and measurements - Part 6-4: Dynamic stress tests - Test 6d: Vibration (sinusoidal) |
EN 50289-1-14:2004 | Communication cables - Specifications for test methods - Part 1-14: Electrical test methods - Coupling attenuation or screening attenuation of connecting hardware |
IEC 60512-15-6:2008 | Connectors for electronic equipment - Tests and measurements - Part 15-6: Connector tests (mechanical) - Test 15f: Effectiveness of connector coupling devices |
IEC 60512-25-9:2008 | Connectors for electronic equipment - Tests and measurements - Part 25-9: Signal integrity tests - Test 25i: Alien crosstalk |
IEC 60050-581:2008 | International Electrotechnical Vocabulary (IEV) - Part 581: Electromechanical components for electronic equipment |
IEC 60512-1-2:2002 | Connectors for electronic equipment - Tests and measurements - Part 1-2: General examination - Test 1b: Examination of dimension and mass |
IEC 60352-7:2002 | Solderless connections - Part 7: Spring clamp connections - General requirements, test methods and practical guidance |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.