IEC 61046:1993
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
D.C. or a.c. supplied electronic step-down convertors for filament lamps - General and safety requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
10-13-2000
11-11-1993
Contents
Foreword
Section 1 - General requirements
1. General
1.1 Scope
1.2 Normative references
2. Definitions
3. General requirements
4. General notes on tests
5. Classification
6. Marking
Section 2 - Safety requirements
7. Terminals
8. Provisions for earthing
9. Construction
10. Creepage distances and clearances
11. Protection against accidental contact with live parts
12. Moisture resistance and insulation
13. Electric strength
14. Transformer heating
15 Abnormal conditions
16. Fault conditions
17. Screws, current-carrying parts and connections
18. Resistance to heat and fire
19. Resistance to corrosion
Figure 1
Annexes
A. Test to establish whether a conductive part is a
live part which may cause an electric shock
B. Particular requirements for d.c. or a.c. supplied
electronic step-down convertors for filament lamps
with means of protection against overheating
C. Particular additional requirements for independent
SELV d.c. or a.c. supplied electronic step-down
convertors for filament lamps
Specifies general and safety requirements for electronic step-down convertors for use on d.c. supplies up to 250 V or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.
Committee |
TC 34/SC 34C
|
DevelopmentNote |
BS DRAFTS 93/211259 DC AND 94/202328 DC REFER TO AMENDMENT
|
DocumentType |
Standard
|
Pages |
100
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NF EN 61046 : 95 AMD 1 96 | Identical |
GOST R IEC 1046 : 1998 | Identical |
GOST IEC 61046 : 2012 | Identical |
NEN 11046 : 94 AMD 1 96 | Identical |
I.S. EN 61046:1995 | Identical |
AS/NZS 61046:2001 | Identical |
VDE 0712-24 : 95 AMD 1 97 | Identical |
CEI EN 61046 : 2ED 1998 | Identical |
EN 61046:1994/A1:1996 | Corresponds |
DIN EN 61046 : 1995 AMD 1 1997 | Identical |
UNE-EN 61046:1996 | Identical |
PREN 12665 : DRAFT 2009 | LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
CEI EN 60598-2-6 : 1998 | LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS - SECTION 6: LUMINAIRES WITH BUILT-IN TRANSFORMERS FOR FILAMENT LAMPS |
VDE 0711-2-23 : 2001 | LUMINAIRES - PART 2-23: PARTICULAR REQUIREMENTS - EXTRA LOW-VOLTAGE LIGHTING SYSTEMS FOR FILAMENT LAMPS |
10/30217290 DC : DRAFT FEB 2010 | BS EN 60364-7-715 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-715: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXTRA-LOW-VOLTAGE LIGHTING INSTALLATIONS |
HD 384.7.711 : 200S1 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-711: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXHIBITIONS, SHOWS AND STANDS |
I.S. EN 60598-2-6:1995 | LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS - SECTION 6: LUMINAIRES WITH BUILT-IN TRANSFORMERS OR CONVERTERS FOR FILAMENT LAMPS |
NF EN 60598 2-23 : 97 AMD 1 2001 | LUMINARIES - PART 2: PARTICULAR REQUIREMENTS - SECTION 23: EXTRA LOW-VOLTAGE LIGHTING SYSTEMS FOR FILAMENT LAMPS |
EN 60598-2-23:1996/A1:2000 | LUMINAIRES - PART 2-23: PARTICULAR REQUIREMENTS - EXTRA LOW VOLTAGE LIGHTING SYSTEMS FOR FILAMENT LAMPS |
VDE 0711-223 : 1997 | LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS - SECTION 23: EXTRA LOW-VOLTAGE LIGHTING SYSTEMS FOR FILAMENT LAMPS |
09/30185891 DC : 0 | BS EN 12665 - LIGHT AND LIGHTING - BASIC TERMS AND CRITERIA FOR SPECIFYING LIGHTING REQUIREMENTS |
I.S. HD 384.7.711:2003 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-711: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - EXHIBITIONS, SHOWS AND STANDS |
CSA E598.1 : 2002 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
IEC 60364-7-740:2000 | Electrical installations of buildings - Part 7-740: Requirements for special installations or locations - Temporary electrical installations for structures, amusement devices and booths at fairgrounds, amusement parks and circuses |
I.S. HD 60364-7-740:2006 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES |
IEC 60598-2-23:1996+AMD1:2000 CSV | Luminaires - Part 2-23: Particular requirements - Extra low voltage lighting systems for filament lamps |
BS EN 60598-2-23:1997 | Luminaires. Particular requirements Extra low voltage lighting systems for filament lamps |
S.R. HD 60364-7-740:2006 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES |
IEC 60598-2-6:1994 | Luminaires - Part 2: Particular requirements - Section 6: Luminaires with built-in transformers for filament lamps |
EN 60598-2-6:1994/A1:1997 | LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS - SECTION 6: LIMINAIRES WITH BUILT-IN TRANSFORMERS OR CONVERTERS FOR FILAMENT LAMPS |
HD 60364-7-740:2006/A11:2017 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 7-740: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - TEMPORARY ELECTRICAL INSTALLATIONS FOR STRUCTURES, AMUSEMENT DEVICES AND BOOTHS AT FAIRGROUNDS, AMUSEMENT PARKS AND CIRCUSES |
IEC 60730-2-3:2006 | Automatic electrical controls for household and similar use - Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps |
IEC 60127:1974 | Cartridge fuse-links for miniature fuses |
IEC 60695-2-1:1991 | Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60269-2:2013+AMD1:2016 CSV | Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K |
IEC 61047:2004 | DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
IEC 60691:2015 | Thermal-links - Requirements and application guide |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
ISO 4046:1978 | Paper, board, pulp and related terms — Vocabulary |
IEC 60051:1973 | Recommendations for direct acting indicating electrical measuring instruments and their accessories |
IEC 60920:1990 | Ballasts for tubular fluorescent lamps - General and safety requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.