IEC 61031:1990
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Design, location and application criteria for installed area gamma radiation dose rate monitoring equipment for use in nuclear power plants during normal operation and anticipated operational occurrences
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
09-12-2022
English - French, Russian
06-01-1990
FOREWORD
Clause
1 Scope
2 Normative references
3 Definitions
4 Application criteria
5 Location criteria
6 Equipment design principles
7 Calibration
8 Testing
Annex A Examples of locations and measuring ranges of area
radiation monitors
Provides guidelines for the design principles, the location, the application, the calibration, the operation, and the testing of installed equipment for continuously monitoring local gamma radiation dose rates in nuclear power plants under normal operation conditions and anticipated operational occurrences.
Committee |
TC 45/SC 45A
|
DevelopmentNote |
Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
21
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
NEN 11031 : 1991 | Identical |
IEC 62705:2014 | Nuclear power plants - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle |
16/30324061 DC : 0 | BS IEC 61504 ED2.0 - NUCLEAR FACILITIES INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - CENTRALIZED SYSTEMS FOR CONTINUOUS MONITORING OF RADIATION AND/OR LEVELS OF RADIOACTIVITY |
BS IEC 62705:2014 | Nuclear power plants. Instrumentation and control important to safety. Radiation monitoring systems (RMS): Characteristics and lifecycle |
BS IEC 61504:2017 | Nuclear facilities. Instrumentation and control systems important to safety. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
IEC 61504:2017 | Nuclear facilities - Instrumentation and control systems important to safety - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
BIS IS 10322-1 : 2014 | LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS |
13/30249610 DC : 0 | BS EN 62705 ED 1.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - RADIATION MONITORING SYSTEMS (RMS) CHARACTERISTICS AND TEST METHODS |
IEC 60532:2010 | Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV |
IEC 60951-3:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 3: Equipment for continuous high range area gamma monitoring |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.