Safety requirements for electrical equipment for measurement, control and laboratory use - Part 031: Safety requirements for hand-held probe assemblies for electrical measurement and test
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-22-2022
English
05-29-2015
IEC 61010-031:2015 RLV contains both the official IEC International Standard and its Redline version. The Redline version is available in English only and provides you with a quick and easy way to compare all the changes between the official IEC Standard and its previous edition.
IEC 61010-031:2015 specifies safety requirements for hand-held and hand-manipulated probe assemblies of the types described below, and their related accessories. These probe assemblies are for direct electrical connection between a part and electrical test and measurement equipment. They may be fixed to the equipment or be detachable accessories for the equipment. It has the status of a group safety publication in accordance with IEC GUIDE 104. IEC 61010-031 is a stand-alone standard. This second edition cancels and replaces the first edition published in 2002 and Amendment 1:2008. This edition constitutes a technical revision. This edition includes the following significant changes from the first edition, as well as numerous other changes:
a) Voltages above the levels of 30 V r.m.s., 42,4 V peak, or 60 V d.c. are deemed to be HAZARDOUS LIVE instead of 33 V r.m.s., 46,7 V peak, or 70 V d.c.
b) Servicing is now included within the scope.
c) Extended environmental conditions are included within the scope.
d) New terms have been defined.
e) Tests for REASONABLY FORESEEABLE MISUSE have been added, in particular for fuses.
f) Additional instruction requirements for probe assembly operation have been specified.
g) Limit values for ACCESSIBLE parts and for measurement of voltage and touch current have been modified.
h) SPACINGS requirements for mating of CONNECTORS have been modified.
i) PROBE TIPS and SPRING-LOADED CLIPS requirements have been modified. The PROTECTIVE FINGERGUARD replace the BARRIER with new requirements.
j) Insulation requirements (6.5) and test procedures (6.6.5) have been rewritten and aligned when relevant with Part 1. Specific requirements have been added for solid insulation and thin-film insulation.
k) The terminology for MEASUREMENT CATEGORY I has been replaced with the designation "not RATED for measurements within MEASUREMENT CATEGORIES II, III, or IV".
l) The flexing/pull test (6.7.4.3) has been partially rewritten.
m) Surface temperature limits (Clause 10) have been modified to conform to the limits of IEC Guide 117.
n) Requirements for resistance of PROBE WIRES to mechanical stresses have been added in Clause 12 and a new Annex D.
o) Requirements have been added regarding the prevention of HAZARD from arc flash and short-circuits for SPRING-LOADED CLIPS.
p) A new informative Annex E defines the dimension of the 4 mm banana CONNECTORS.
Committee |
TC 66
|
DevelopmentNote |
Supersedes IEC 61010-2-031. (02/2002) Stability Date: 2021. (05/2018)
|
DocumentType |
Redline
|
Pages |
284
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
PN EN 61010-031 : 2015 | Identical |
BS EN 61010-031:2015 | Identical |
DIN EN 61010-031 : 2016 COR 1 2017 | Identical |
NEN EN IEC 61010-031 : 2015 | Identical |
CEI EN 61010-031 : 2015 | Identical |
EN 61010-031:2015 | Identical |
GOST IEC 61010-031 : 2013 | Identical |
NF EN 61010-031 : 2015 | Identical |
VDE 0411-031 : 2016 COR 1 2017 | Identical |
NBN EN 61010-031 : 2015 | Identical |
DS EN 61010-031 : 2015 | Identical |
ONORM OVE EN 61010-031 : 2016 AC 2017 | Identical |
ISA 61010-031 : 2007 | Identical |
UNE-EN 61010-031:2004 | Identical |
BS EN 62353:2014 | Medical electrical equipment. Recurrent test and test after repair of medical electrical equipment |
08/30184169 DC : DRAFT JUNE 2008 | BS EN 61243-3 - LIVE WORKING - VOLTAGE DETECTORS - PART 3: TWO-POLE LOW-VOLTAGE TYPE |
I.S. EN 61557-16:2015 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 16: EQUIPMENT FOR TESTING THE EFFECTIVENESS OF THE PROTECTIVE MEASURES OF ELECTRICAL EQUIPMENT AND/OR MEDICAL ELECTRICAL EQUIPMENT |
CSA C22.2 No. 61010.1 : 2012 : FR | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
CEI EN 61557-14 : 2014 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 14: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT OF MACHINERY |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 :2015 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
PD IEC/TR 62354:2014 | General testing procedures for medical electrical equipment |
EN 61557-14:2013 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 14: Equipment for testing the safety of electrical equipment of machinery |
EN 61243-3:2014/AC:2015 | LIVE WORKING - VOLTAGE DETECTORS - PART 3: TWO-POLE LOW-VOLTAGE TYPE |
EN 62353:2014 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
15/30328086 DC | BS EN 61557-12. Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Part 12. Power metering and monitoring devices (PMD) |
10/30219049 DC : 0 | BS EN 62638 - RECURRENT TEST AND TEST AFTER REPAIR AND MODIFICATION OF ELECTRICAL EQUIPMENT |
BS EN 61243-3:2014 | Live working. Voltage detectors Two-pole low-voltage type |
I.S. EN 62353:2014 | MEDICAL ELECTRICAL EQUIPMENT - RECURRENT TEST AND TEST AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT |
NF EN 61010-1 : 2011 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
ANSI/AAMI/IEC TIR62354:2015 | GENERAL TESTING PROCEDURES FOR MEDICAL ELECTRICAL EQUIPMENT |
EN 61010-1:2010 | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 62353:2014 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
BIS IS/IEC 62353 : 2007 | MEDICAL ELECTRICAL EQUIPMENT - RECURRENT TEST AND TEST AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT |
13/30250915 DC : 0 | BS EN 62353 - MEDICAL ELECTRICAL EQUIPMENT - RECURRENT TEST AND TEST AFTER REPAIR OF MEDICAL ELECTRICAL EQUIPMENT |
12/30262863 DC : 0 | BS EN 61557-16 - ELECTRICAL SAFETY IN DISTRIBUTION SYSTEMS UP TO 1000 V A.C AND 1500 V D.C - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 16: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL EQUIPMENT ACCORDING TO IEC 62638 AND IEC 62353 |
UNE-EN 62353:2015 | Medical electrical equipment - Recurrent test and test after repair of medical electrical equipment |
I.S. EN 61557-14:2013 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1 000 V A.C. AND 1 500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 14: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT OF MACHINERY (IEC 61557-14:2013 (EQV)) |
CAN/CSA-C22.2 NO. 61010-1-12 (R2017) | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements (Tri-national standard, with UL 61010-1 and ANSI/ISA-61010-1 (82.02.01) |
ISO 15190:2003 | Medical laboratories Requirements for safety |
I.S. EN 61557-9:2015 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
UNE-EN 61010-1:2011 | Safety requirements for electrical equipment for measurement, control and laboratory use -- Part 1: General requirements |
ISA 61010-1 : 2008 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
10/30216301 DC : 0 | BS EN 61557-14 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C AND 1500 V D.C. EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 14: EQUIPMENT FOR TESTING THE SAFETY OF ELECTRICAL EQUIPMENT FOR MACHINERY |
BS EN 61557-16:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment |
07/30168572 DC : 0 | BS IEC 61010-1 - SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
BS ISO 15190:2003 | Medical laboratories. Requirements for safety |
CSA Z15190 : 2005 : R2015 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
CSA Z15190 : 2005 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
CSA Z15190 : 2005 : R2010 | MEDICAL LABORATORIES - REQUIREMENTS FOR SAFETY |
I.S. EN 61243-3:2014 | LIVE WORKING - VOLTAGE DETECTORS - PART 3: TWO-POLE LOW-VOLTAGE TYPE |
IEC TR 62354:2014 | General testing procedures for medical electrical equipment |
PD IEC/TS 62850:2013 | Safety requirements for electrical equipment for measurement, control, and laboratory use. General requirements for equipment intended to be used in educational establishments by children |
IEC TS 62850:2013 | Safety requirements for electrical equipment for measurement, control, and laboratory use - General requirements for equipment intended to be used in educational establishments by children |
IEC 61557-9:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 9: Equipment for insulation fault location in IT systems |
IEC 61243-3:2014 | Live working - Voltage detectors - Part 3: Two-pole low-voltage type |
IEC 61557-16:2014 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment |
UNE-EN 61243-3:2015 | Live working - Voltage detectors - Part 3: Two-pole low-voltage type |
BS EN 61557-14:2013 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for testing the safety of electrical equipment of machinery |
CSA C22.2 No. 61010.1 :2012 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 : 2015 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 2 :2016 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
CSA C22.2 No. 61010.1 : 2012 : INC : UPD 2 : 2016 | SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS |
12/30274737 DC : 0 | BS EN 61557-9 - ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS |
IEC 61557-14:2013 | Electrical safety in low voltage distribution systems up to 1 000 V a.c and 1 500 V d.c - Equipment for testing,measuring or monitoring of protective measures - Part 14: Equipment for testing the safety of electrical equipment for machinery |
BS EN 61557-9:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures Equipment for insulation fault location in IT systems |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
EN 61557-9:2015/AC:2017-02 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 9: EQUIPMENT FOR INSULATION FAULT LOCATION IN IT SYSTEMS (IEC 61557-9:2014/COR2:2017) |
EN 61557-16:2015 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 16: Equipment for testing the effectiveness of the protective measures of electrical equipment and/or medical electrical equipment |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60664-4:2005 | Insulation coordination for equipment within low-voltage systems - Part 4: Consideration of high-frequency voltage stress |
IEC 60050-195:1998 | International Electrotechnical Vocabulary (IEV) - Part 195: Earthing and protection against electric shock |
IEC 60050-151:2001 | International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices |
IEC 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60364-4-44:2007+AMD1:2015 CSV | Low-voltage electrical installations - Part 4-44: Protection for safety - Protection against voltage disturbances and electromagnetic disturbances |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.