IEC 60947-5-9:2006
Current
The latest, up-to-date edition.
Low-voltage switchgear and controlgear - Part 5-9: Control circuit devices and switching elements - Flow rate switches
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
12-08-2006
FOREWORD
1 General
1.1 Scope and object
1.2 Normative references
2 Terms and definitions
2.1 Basic definitions
2.2 Characteristics of a flow rate switch
2.3 Delay times
3 Classification
3.1 General
3.2 Classification according to sensing means
3.3 Classification according to the construction form
3.4 Classification according to the switching element function
3.5 Classification according to the type of output
3.6 Classification according to the method of connection
4 Characteristics
4.1 Summary of characteristics
4.2 Operating conditions
4.3 Rated and limiting values for the flow rate switch
4.4 Utilization categories for the switching element
5 Product information
5.1 Nature of information
5.2 Marking
5.3 Instruction for installation, operation and maintenance
6 Normal service, mounting and transport conditions
6.1 Normal service conditions
6.2 Conditions during transport and storage
6.3 Mounting
6.4 Indicating means
7 Constructional and performance requirements
7.1 Constructional requirements
7.2 Performance requirements
7.3 Shock and vibration
8 Tests
8.1 Kinds of tests
8.2 Compliance with constructional requirements
8.3 Performance
8.4 Verification of set point and delay times
8.5 Verification of the electromagnetic compatibility
8.6 Test results and test report
This part of IEC 60947 applies to flow rate switches that sense the rate of flow of a gas, a liquid or a granular solid. These switches change their output state if a pre-set value for the speed of flow is exceeded. These flow rate switches are self-contained, have semiconductor switching element(s) and are intended to be connected to circuits, the rated voltage of which does not exceed 250 V 50 Hz/60 Hz a.c. or 300 V d.c.
DevelopmentNote |
Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
69
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
NF EN 60947-5-9 : 2008 | Identical |
NEN EN IEC 60947-5-9 : 2007 | Identical |
I.S. EN 60947-5-9:2007 | Identical |
PN EN 60947-5-9 : 2010 | Identical |
AS/NZS IEC 60947.5.9:2015 | Identical |
SAC GB/T 14048-21 : 2013 | Identical |
VDE 0660-216 : 2008 | Identical |
UNE-EN 60947-5-9:2008 | Identical |
BS EN 60947-5-9:2007 | Identical |
CEI EN 60947-5-9 : 2008 | Identical |
EN 60947-5-9:2007 | Identical |
DIN EN 60947-5-9 : 2008 | Identical |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 60947-1:2007+AMD1:2010+AMD2:2014 CSV | Low-voltage switchgear and controlgear - Part 1: General rules |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60947-5-2:2007+AMD1:2012 CSV | Low-voltage switchgear and controlgear - Part 5-2: Control circuitdevices and switching elements - Proximity switches |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.