IEC 60939-2:2005
Current
The latest, up-to-date edition.
Passive filter units for electromagnetic interference suppression - Part 2: Sectional specification - Passive filter units for which safety tests are appropriate - Test methods and general requirements
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
02-10-2005
FOREWORD
1 General
1.1 Scope
1.2 Normative references
1.3 Information to be given in a detail specification
1.4 Definitions
1.5 Marking
2 Preferred ratings and characteristics
2.1 Preferred characteristics
2.2 Preferred values of ratings
3 Quality assessment procedures
3.1 Primary stage of manufacture
3.2 Structurally similar filters
3.3 Certified records of released lots
3.4 Approval testing
3.5 Quality conformance inspection
4 Test and measurement procedures
4.1 Earth inductors incorporated in filters
4.2 Capacitance and tan delta measurements
4.3 Visual examination and check of dimensions
4.4 Voltage proof
4.5 Insulation resistance
4.6 DC line resistance or voltage drop at rated current
4.7 Insertion loss
4.8 Discharge resistance
4.9 Robustness of terminations
4.10 Resistance to soldering heat
4.11 Solderability
4.12 Rapid change of temperature
4.13 Vibration
4.14 Bump
4.15 Shock
4.16 Container sealing
4.17 Climatic sequence
4.18 Damp heat, steady state
4.19 Temperature rise
4.20 Impulse voltage
4.21 Endurance
4.22 Charge and discharge
4.23 Passive flammability
4.24 Current overload
4.25 Solvent resistance of the marking
4.26 Component solvent resistance
4.27 Active flammability
Annex A (normative) Test schedule for qualification approval
- Assessment level D/DZ
Annex B (normative) Test schedule for safety requirements only
Annex C (normative) Circuit for the impulse voltage test
Annex D (normative) Circuit for the endurance test
Annex E (normative) Declaration of design
Figures
Tables
IEC 60939-2:2005 applies to passive filter units for electromagnetic interference suppression which fall within the scope of the Generic Specification IEC 60939-1. The scope of this Sectional specification is restricted to passive filter units for which safety tests are appropriate. This implies that filters specified according to this Sectional specification will either be connected to mains supplies, when compliance with the mandatory tests of Table 3 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. The contents of the corrigendum of November 2005 have been included in this copy.
Committee |
TC 40
|
DevelopmentNote |
Stability Date: 2018. (10/2012)
|
DocumentType |
Standard
|
Pages |
68
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
IS 13247 : Part 2 : 2021 | Identical |
DS EN 60939-2 : 2005 | Identical |
NF EN 60939-2 : 2005 | Identical |
NEN EN IEC 60939-2 : 2005 C1 2005 | Identical |
PN EN 60939-2 : 2009 | Identical |
DIN EN 60939-2 : 2006 | Identical |
VDE 0565-3-1 : 2006 | Identical |
BS EN 60939-2:2005 | Identical |
CEI EN 60939-2 : 2005 | Identical |
EN 60939-2:2005 | Identical |
UNE-EN 60939-2:2005 | Identical |
BS EN 60068-2-11:1999 | Identical |
DIN EN 45510-2-7:2003-12 | GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR |
13/30280858 DC : 0 | BS EN 60940 - GUIDANCE INFORMATION ON THE APPLICATION OF CAPACITORS, RESISTORS, INDUCTORS AND COMPLETE FILTER UNITS FOR RADIO INTERFERENCE SUPPRESSION - PART 8: SECTIONAL SPECIFICATION: FIXED CAPACITORS OF CERAMIC DIELECTRIC, CLASS 1 |
IEC TR 61000-5-6:2002 | Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences |
BS EN 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
BS EN 61000-5-5:1996 | Electromagnetic compatibility (EMC). Installation and mitigation guidelines Specification of protective devices for HEMP conducted disturbance. Basic EMC publication |
PD IEC TR 61000-5-6:2002 | Electromagnetic compatibility (EMC). Installation and mitigation guidelines Mitigation of external EM influences |
NF EN 60939-2-2 : 2005 | COMPLETE FILTER UNITS FOR RADIO INTERFERENCE SUPPRESSION - PART 2-2: BLANK DETAIL SPECIFICATION - PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - FILTERS FOR WHICH SAFETY TESTS ARE REQUIRED (SAFETY TESTS ONLY) |
I.S. EN 60939-2-1:2004 | COMPLETE FILTER UNITS FOR RADIO INTERFERENCE SUPPRESSION - PART 2-1: BLANK DETAIL SPECIFICATION - PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - FILTERS FOR WHICH SAFETY TESTS ARE REQUIRED (ASSESSMENT LEVEL D/DZ) |
EN 61000-5-5:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance |
BS EN 60939-2-2:2004 | Complete filter units for radio interference suppression Blank detail specification. Passive filter units for electromagnetic interference suppression. Filters for which safety tests are required (safety tests only) |
IEC 60939-2-1:2004 | Complete filter units for radio interference suppression - Part 2-1: Blank detail specification - Passive filter units for electromagnetic interference suppression - Filters for which safety tests are required (assessment level D/DZ) |
IEC 60939-2-2:2004 | Complete filter units for radio interference suppression - Part 2-2: Blank detail specification - Passive filter uits for electromagnetic interference suppression - Filters for which safety tests are required (safety tests only) |
IEC 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
IEC 61000-5-5:1996 | Electromagnetic compatibility (EMC) - Part 5: Installation and mitigation guidelines - Section 5: Specification of protective devices for HEMP conducted disturbance. Basic EMC Publication |
BS EN 60939-2-1:2004 | Complete filter units for radio interference suppression Blank detail specification. Passive filter units for electromagnetic interference suppression. Filters for which safety tests are required (Assessment level D/DZ) |
I.S. EN 60940:2015 | GUIDANCE INFORMATION ON THE APPLICATION OF CAPACITORS, RESISTORS, INDUCTORS AND COMPLETE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION |
I.S. EN 60939-2-2:2004 | COMPLETE FILTER UNITS FOR RADIO INTERFERENCE SUPPRESSION - PART 2-2: BLANK DETAIL SPECIFICATION - PASSIVE FILTER UNITS FOR ELECTROMAGNETIC INTERFERENCE SUPPRESSION - FILTERS FOR WHICH SAFETY TESTS ARE REQUIRED (SAFETY TESTS ONLY) |
EN 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
EN 60939-2-2:2004 | Complete filter units for radio interference suppression - Part 2-2: Blank detail specification - Passive filter units for electromagnetic interference suppression - Filters for which safety tests are required (safety tests only) |
EN 60939-2-1:2004 | Complete filter units for radio interference suppression - Part 2-1: Blank detail specification - Passive filter units for electromagnetic interference suppression - Filters for which safety tests are required (assessment level D/DZ) |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60939-1:2010 | Passive filter units for electromagnetic interference suppression - Part 1: Generic specification |
IEC 60384-9:2015 | Fixed capacitors for use in electronic equipment - Part 9: Sectional specification: Fixed capacitors of ceramic dielectric, Class 2 |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60938-1:1999+AMD1:2006 CSV | Fixed inductors for electromagnetic interference suppression - Part 1: Generic specification |
IEC 60940:2015 | Guidance information on the application of capacitors, resistors, inductors and complete filter units for electromagnetic interference suppression |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 60062:2016 | Marking codes for resistors and capacitors |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.