IEC 60898:1995
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-24-2002
English - French
02-22-1995
Foreword
1. General
1.1 Scope
1.2 Object
2. Normative references
3. Definitions
3.1 Devices
3.2 General terms
3.3 Constructional elements
3.4 Conditions of operation
3.5 Characteristic quantities
4. Classification
4.1 According to the number of poles
4.2 According to the protection against external influences
4.3 According to the method of mounting
4.4 According to the method of connection
4.5 According to the instantaneous tripping current
4.6 According to the I2t characteristic
5. Characteristics of circuit-breakers
5.1 List of characteristics
5.2 Rated quantities
5.3 Standard and preferred values
6. Marking and other product information
7. Standard conditions for operation in service
7.1 Ambient air temperature range
7.2 Altitude
7.3 Atmospheric conditions
7.4 Conditions of installation
8. Requirements for construction and operation
8.1 Mechanical design
8.2 Protection against electric shock
8.3 Dielectric properties
8.4 Temperature-rise
8.5 Uninterrupted duty
8.6 Automatic operation
8.7 Mechanical and electrical endurance
8.8 Performance at short-circuit currents
8.9 Resistance to mechanical shock and impact
8.10 Resistance to heat
8.11 Resistance to abnormal heat and to fire
8.12 Resistance to rusting
9. Tests
9.1 Type tests and test sequences
9.2 Test conditions
9.3 Test of indelibility of marking
9.4 Test of reliability of screws, current-carrying parts
and connections
9.5 Test of reliability of terminals for external conductors
9.6 Test of protection against electric shock
9.7 Test of dielectric properties
9.8 Test of temperature rise and measurement of power loss
9.9 28-day test
9.10 Test of tripping characteristic
9.11 Test of mechanical and electrical endurance
9.12 Short-circuit tests
9.13 Test of resistance to mechanical shock and impact
9.14 Test of resistance to heat
9.15 Resistance to abnormal heat and to fire (glow-wire test)
9.16 Test of resistance to rusting
Tables
1 Preferred values of rated voltage
2 Ranges of instantaneous tripping
3 Clearances and creepage distances
4 Connectable cross-sections of copper conductors for screw-type
terminals
5 Temperature-rise values
6 Time-current operating characteristics
7 List of type tests
8 Cross-sectional areas (S) of test copper conductors
corresponding to the rated currents
9 Screw thread diameters and applied torques
10 Pulling forces
11 Conductor dimensions
12 Maximum power loss per pole
13 List of short-circuit-tests
14 Power factor ranges of the test circuit
15 Ratio k between service short-circuit capacity (Ics) and rated
short-circuit capacity (Icn)
16 Test procedure for Ics in the case of single- and two-pole
circuit breakers
17 Test procedure for Ics in the case of three- and four-pole
circuit-breakers
18 Test procedure for Ics in the case of three-phase test for
single-pole circuit-breakers of rated voltage 230/400 V
19 The test procedure for Icn
20 Test procedure for Icn the case of three-phase tests for single-
and two-pole circuit breakers of rated voltage 230/400 V
Figures
Annexes
A Determination of short-circuit power factor
B Determination of clearances and creepage distances
C Number of samples to be submitted and test sequences to be
applied for verification of conformity
D Coordination of circuit-breakers with separate fuses associated
in the same circuit
E Special requirements for auxiliary circuits for safety extra-low
voltage
F Examples of terminals
G Correspondence between ISO and AWG copper conductors
H Arrangements for short-circuit tests
Applies to a.c. air-break circuit-breakers for operation at 50 Hz or 60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding 125 A and a rated short-circuit capacity not exceeding 25 000 A. These circuit-breakers are intended for the protection against overcurrents of wiring installations of buildings and similar applications; they are designed for use by uninstructed people and for not being maintained. Also applies to circuit-breakers having more than one rated current, provided that the means for changing from one discrete rating to another is not accessible in normal service and that the rating cannot be changed without the use of a tool.
Committee |
TC 23/SC 23E
|
DevelopmentNote |
BS DRAFTS 92/05857 DC, 95/205461 DC + 96/211300 DC REFER TO AMD'S
|
DocumentType |
Standard
|
Pages |
177
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
PN IEC 60898 : 2000 | Identical |
SN EN 60898 : 1991 AMD 19 2000 | Identical |
UNE EN 60898 : 1992 A19 2001 | Identical |
DIN VDE 0641-11 : 1992 | Identical |
BS EN 60898:1991 | Identical |
BIS IS 8828 : 1996(R2006) | Identical |
NF EN 60898 : 92 AMD 19 2001 | Identical |
VDE 0641-11 : 2006 AMD 13 2013 | Corresponds |
EN 60898:1991/A19:2000 | Identical |
CEI EN 60898 : 4ED 1999 | Identical |
NEN EN IEC 60898 : 1992 AMD 19 2000 | Identical |
I.S. EN 60898:1992 | Identical |
DIN EN 60898 : AMD 19 2000 | Identical |
DIN VDE 0641-11 : 1992 | Corresponds |
BS 3871-1:1965 | Similar to |
CEI EN 50065-4-1 : 2002 | SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 4-1: LOW-VOLTAGE DECOUPLING FILTERS - GENERIC SPECIFICATION |
13/30289140 DC : 0 | BS EN 60364-9-1 ED 1.0 - LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 9-1: INSTALLATION DESIGN AND,,SAFETY REQUIREMENTS FOR PHOTOVOLTAIC POWER SYSTEMS (PV) |
BS EN 61400-1 : 2005 | WIND TURBINES - PART 1: DESIGN REQUIREMENTS |
BS EN 61000-4-27 : 2001 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-27: TESTING AND MEASUREMENT TECHNIQUES - UNBALANCE, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE |
CSA C61400-3 : 2011 : R2016 | WIND TURBINES - PART 3: DESIGN REQUIREMENTS FOR OFFSHORE WIND TURBINES |
CSA C61400-1 : 2014 | WIND TURBINES - PART 1: DESIGN REQUIREMENTS |
NF EN 60934 : 2001 AMD 2 2013 | CIRCUIT-BREAKERS FOR EQUIPMENT (CBE) |
BS EN 12414:1999 | Vehicle parking control equipment. Pay and display ticket machine. Technical and functional requirements |
06/30154990 DC : 0 | BS EN 60204-32 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 32: REQUIREMENTS FOR HOISTING MACHINES |
EN 62019:1999/A12:2014 | ELECTRICAL ACCESSORIES - CIRCUIT-BREAKERS AND SIMILAR EQUIPMENT FOR HOUSEHOLD USE - AUXILIARY CONTACT UNITS |
EN 61000-4-27:2000/A1:2009 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-27: TESTING AND MEASUREMENT TECHNIQUES - UNBALANCE, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE |
EN 61400-3:2009 | Wind turbines - Part 3: Design requirements for offshore wind turbines |
BS EN 61400-3:2009 | Wind turbines Design requirements for offshore wind turbines |
IEC 61545:1996 | Connecting devices - Devices for the connection of aluminium conductors in clamping units of any material and copper conductors in aluminium bodied clamping units |
GOST R IEC 60269-3-1 : 2004 | LOW-VOLTAGE FUSES - PART 3-1 - SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - SECTIONS 1 TO 5 |
NF EN 61558-1 : 2006 AMD 1 2009 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLIES, REACTORS AND SIMILAR PRODUCTS - PART 1: GENERAL REQUIREMENTS AND TESTS |
I.S. EN 61000-4-27:2000 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-27: TESTING AND MEASUREMENT TECHNIQUES - UNBALANCE, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE |
CEI EN 50171 : 2002 | CENTRAL POWER SUPPLY SYSTEMS |
I.S. EN 12613:2009 | PLASTICS WARNING DEVICES FOR UNDERGROUND CABLES AND PIPELINES WITH VISUAL CHARACTERISTICS |
EN 61400-1:2005/A1:2010 | WIND TURBINES - PART 1: DESIGN REQUIREMENTS |
BS 88-3:2007 | Low-voltage fuses Supplementary requirements for fuses for use by unskilled persons (fuses mainly for household or similar applications). Examples of standardized systems of fuses A to F |
BIS IS/IEC 60947-2 : 2003 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT BREAKERS |
VDE 0129-507 : 2001 | ELECTRICAL INSTALLATIONS IN SHIPS - PART 507: PLEASURE CRAFT (IEC 60092-507:2000) |
NEMA AB 1 | Molded-Case Circuit Breakers, Molded Case Switches, and Circuit-Breaker Enclosures |
03/318811 DC : DRAFT NOV 2003 | IEC 62257-5 TS ED.1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 5: SAFETY RULES - PROTECTION AGAINST ELECTRICAL HAZARDS |
16/30338981 DC : 0 | BS EN 60934 - CIRCUIT-BREAKERS FOR EQUIPMENT (CBE) |
BS EN 50171:2001 | Central power supply systems |
CEI EN 61400-3 : 2009 | WIND TURBINES - PART 3: DESIGN REQUIREMENTS FOR OFFSHORE WIND TURBINES |
03/109124 DC : DRAFT JUNE 2003 | IEC 61400-1 ED.3.0 - WIND TURBINES - PART 1: DESIGN REQUIREMENTS |
BIS IS 12640-2 : 2008 | RESIDUAL CURRENT OPERATED CIRCUIT-BREAKING FOR HOUSEHOLD AND SIMILAR USES - PART 2: CIRCUIT-BREAKERS WITH INTEGRAL OVERCURRENT PROTECTION (RCBOS) |
BS EN 60934 : 2001 | CIRCUIT-BREAKERS FOR EQUIPMENT (CBE) |
I.S. EN 62019:2000 | ELECTRICAL ACCESSORIES - CIRCUIT-BREAKERS AND SIMILAR EQUIPMENT FOR HOUSEHOLD USE - AUXILIARY CONTACT UNITS |
NFC 61 203 : 2005 | LOW-VOLTAGE FUSES - PART 3-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - SECTIONS I TO IV: EXAMPLES OF TYPES OF STANDARDIZED FUSES |
I.S. EN 61400-1:2005 | WIND TURBINES - PART 1: DESIGN REQUIREMENTS |
04/30123989 DC : DRAFT OCT 2004 | IEC 61643-11 - SURGE PROTECTION DEVICES CONNECTED TO LOW-VOLTAGE POWER DISTRIBUTION SYSTEMS - PART 11: PERFORMANCE REQUIREMENTS AND TESTING METHODS |
04/30124138 DC : DRAFT OCT 2004 | IEC 60364-5-53 ED.4 - ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 5-53: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - ISOLATION, SWITCHING AND CONTROL |
05/30135654 DC : DRAFT JUN 2005 | IEC 60269-3 ED 3 - LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD OR SIMILAR APPLICATION) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F |
NF HD 60269-3 : 2007 | LOW-VOLTAGE FUSES - PART 3: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD OR SIMILAR APPLICATIONS) - EXAMPLES OF STANDARDIZED SYSTEMS OF FUSES A TO F |
CEI UNI EN 12414 : 2001 | VEHICLE PARKING CONTROL EQUIPMENT - PAY AND DISPLAY TICKET MACHINE - TECHNICAL AND FUNCTIONAL REQUIREMENTS |
CEI 13-26 : 1999 | WATT-HOUR METERS AND POWER LIMITERS FOR LOW-VOLTAGE NETWORKS (INTEGRATED UNITS) PERMITTED OR NOT FOR PROCESSING AND REMOTE MANAGEMENT OF DATA |
PD IEC/TS 62548:2013 | Photovoltaic (PV) arrays. Design requirements |
IEC 61000-4-27:2000+AMD1:2009 CSV | Electromagnetic compatibility (EMC) - Part 4-27: Testing and measurement techniques - Unbalance, immunity test for equipment with input current not exceeding 16 A per phase |
IEC 61400-1:2005+AMD1:2010 CSV | Wind turbines - Part 1: Design requirements |
IEC 61400-3:2009 | Wind turbines - Part 3: Design requirements for offshore wind turbines |
IEC 62019:1999+AMD1:2002 CSV | Electrical accessories - Circuit-breakers and similar equipment for household use - Auxiliary contact units |
UNE-EN 61400-1:2006 | Wind turbines - Part 1: Design requirements |
CEI 32-14 : 1998 | HIGH-VOLTAGE FUSES - PART 2: EXPULSION FUSES |
DIN VDE 0660-101 : 1992 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT BREAKERS |
15/30314469 DC : 0 | BS EN 62548 ED.1 - PHOTOVOLTAIC (PV) ARRAYS - DESIGN REQUIREMENTS |
I.S. HD 630.3.1:2003 | LOW-VOLTAGE FUSES - PART 3-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - SECTIONS 1 TO 4 |
01/203905 DC : DRAFT MAY 2001 | PRHD 630.3.1 S3 - LOW VOLTAGE FUSES - PART 3-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY UNSKILLED PERSONS (FUSES MAINLY FOR HOUSEHOLD AND SIMILAR APPLICATIONS) - SECTIONS 1 TO 4 |
CSA C61400-3 : 2011 | WIND TURBINES - PART 3: DESIGN REQUIREMENTS FOR OFFSHORE WIND TURBINES |
I.S. EN 60934:2001 | CIRCUIT BREAKERS FOR EQUIPMENT (CBE) (IEC 60934:2000 (EQV)) |
I.S. EN 61400-3:2009 | WIND TURBINES - PART 3: DESIGN REQUIREMENTS FOR OFFSHORE WIND TURBINES |
NF EN 62019 : 99 AMD 12 2015 | ELECTRICAL ACCESSORIES - CIRCUIT-BREAKERS AND SIMILAR EQUIPMENT FOR HOUSEHOLD USE - AUXILIARY CONTACT UNITS |
NF EN 60947-2 : 2006 AMD 2 2013 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: CIRCUIT-BREAKERS |
02/203840 DC : DRAFT MAY 2002 | IEC 60204-1/ED.5.0 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
IEC 60934:2000+AMD1:2007+AMD2:2013 CSV | Circuit-breakers for equipment (CBE) |
EN 60934:2001/A2:2013 | CIRCUIT BREAKERS FOR EQUIPMENT (CBE) (IEC 60934:2000/A2:2013) |
EN 50171 : 2001 COR 2001 | CENTRAL POWER SUPPLY SYSTEMS |
DIN EN 61558-2-17 : 1998 | SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR - PART 2-17: PARTICULAR REQUIREMENTS FOR TRANSFORMERS FOR SWITCH MODE POWER SUPPLIES |
CSA CEI/IEC 61000.4.27 : 2001 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-27: TESTING AND MEASUREMENT TECHNIQUES - UNBALANCE, IMMUNITY TEST FOR EQUIPMENT WITH INPUT CURRENT NOT EXCEEDING 16 A PER PHASE |
IEC 60038:2009 | IEC standard voltages |
IEC 60364-4-41:2005+AMD1:2017 CSV | Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 60269-1:2006+AMD1:2009+AMD2:2014 CSV | Low-voltage fuses - Part 1: General requirements |
IEC 60227-1:2007 | Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.