IEC 60870-5-1:1990
Current
The latest, up-to-date edition.
Telecontrol equipment and systems. Part 5: Transmission protocols - Section One: Transmission frame formats
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
02-01-1990
Contents
Foreword
Preface
Introduction
Clause
1. Scope
2. Object
3. Requirements for data transmission in telecontrol
systems
3.1 High data integrity and data consistency
3.2 Shoer telecontrol transfer time
3.3 Support of bit oriented (code transparent)
data transmission
4. Quantified rating of data integrity in telecontrol
systems
5. Quantified rating of transmission efficiency
6. Transmission protocol specifications
6.1 Physical layer
6.2 Link layer
6.2.1 Link service classes provided
6.2.2 Dialogue procedures
6.2.3 Standard frame synchronization
6.2.4 Standard frame formats
6.2.5 Synchronization in transmission channels
using switched carrier frequency
6.2.6 Main application fields of the defined
format classes
6.2.7 Use of HDLC (High level data link control)
-protocols
Appendix A - Effect of signal quality supervision on
transmission efficiency and data integrity
Appendix B - Quantitative ratings of data integrity and
transmission efficiency
Covers asynchronous data transmission with half duplex and duplex link protocols operating with window size one for message transfers.
Specifies the basic requirements for services to be provided by the link plus physical layers, for telecontrol applications. In particular it specifies standards on coding, formatting and synchronizing data frames of variable and filed lengths which meet specified data integrity requirements.
This publication is of high relevance for Smart Grid.
DevelopmentNote |
Also numbered as BS EN 60870-5.1. (12/2005) Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
79
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Standards | Relationship |
GOST R IEC 870-5-1 : 1995 | Identical |
NEN 10870-5-1 : 1994 | Identical |
I.S. EN 60870-5-1:1994 | Identical |
PN EN 60870-5-1 : 2002 | Identical |
SN EN 60870-5-1 : 1993 | Identical |
AS 60870.5.1-1998 | Identical |
BIS IS 12746-5-1 : 1993(R2002) | Identical |
CEI EN 60870-5-1 : 1998 | Identical |
EN 60870-5-1:1993 | Identical |
DIN EN 60870-5-1:1994-07 | Identical |
NF EN 60870 5-1 : 1993 | Identical |
BS 7404-5.1(1991) : 1991 AMD 8113 | Identical |
UNE-EN 60870-5-1:1993 | Identical |
NF EN 60870 5 103 : 1998 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-103: TRANSMISSION PROTOCOLS - COMPANION STANDARD FOR THE INFORMATIVE INTERFACE OF PROTECTION EQUIPMENT |
CEI EN 61375-3-1 : 2013 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-1: MULTIFUNCTION VEHICLE BUS (MVB) |
CEI UNI EN 13757-5 : 2009 | COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 5: WIRELESS RELAYING |
BS IEC 61334-1.2 : 1997 | DISTRIBUTION AUTOMATION USING DISTRIBUTION LINE CARRIER SYSTEMS - GENERAL CONSIDERATIONS - GUIDE FOR SPECIFICATION |
DD CEN/TS 13763-27:2003 | Explosives for civil uses. Detonators and relays Definitions, methods and requirements for electronic initiation systems |
02/206917 DC : DRAFT MAY 2002 | IEC 60870-5-101. ED.2.0 - TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-101: TRANSMISSION PROTOCOLS - COMPANION STANDARD FOR BASIC TELECONTROL TASKS |
09/30205454 DC : 0 | BS EN 61375-3-1 - ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK - PART 3-1: MVB - MULTIPURPOSE VEHICLE BUS |
01/645111 DC : DRAFT JAN 2001 | ISO/IEC 10192-1 - INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) INTERFACES - PART 1: UNIVERSAL INTERFACE CLASS 1 |
11/30249977 DC : 0 | BS EN 13757-4 - COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 4: WIRELESS METER READOUT (RADIO METER READING FOR OPERATION IN SRD BANDS) |
BS EN 60870-5-101 : 2003 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-101: TRANSMISSION PROTOCOLS - COMPANION STANDARD FOR BASIC TELECONTROL TASKS |
BS EN 13757-3:2013 | Communication systems for and remote reading of meters Dedicated application layer |
PREN 13757-3 : DRAFT 2016 | COMMUNICATION SYSTEMS FOR METERS - PART 3: APPLICATION PROTOCOLS |
EN 61784-3-3:2017 | Industrial communication networks - Profiles - Part 3-3: Functional safety fieldbuses - Additional specifications for CPF 3 |
I.S. EN 61784-3-3:2017 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-3: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 3 |
PREN 13757-2 : DRAFT 2016 | COMMUNICATION SYSTEMS FOR METERS - PART 2: WIRED M-BUS COMMUNICATION |
CSA ISO/IEC 14543-3-7 : 2007 : R2012 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-7: MEDIA AND MEDIA DEPENDENT LAYERS - RADIO FREQUENCY FOR NETWORK BASED CONTROL OF HES CLASS 1 |
CSA ISO/IEC 10192-1 : 2004 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) INTERFACES - PART 1: UNIVERSAL INTERFACE (UI) CLASS 1 |
I.S. EN 60044-8:2002 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
CSA C60044-8 : 2007 : R2016 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
CEI UNI EN 13757-4 : 2013 | COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 4: WIRELESS METER READOUT (RADIO METER READING FOR OPERATION IN SRD BANDS) |
GOST R IEC 60870-5-103 : 2005 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5 - TRANSMISSION PROTOCOLS - SECTION 103 - COMPANION STANDARD FOR THE INFORMATIVE INTERFACE OF PROTECTION EQUIPMENT |
PREN 60870-5-6 : DRAFT 2008 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-6: GUIDELINES FOR CONFORMANCE TESTING FOR THE IEC 60870-5 COMPANION STANDARDS |
I.S. EN 62745:2017 | SAFETY OF MACHINERY - REQUIREMENTS FOR CABLELESS CONTROL SYSTEMS OF MACHINERY |
IEC TS 60870-6-602:2001 | Telecontrol equipment and systems - Part 6-602: Telecontrol protocols compatible with ISO standards and ITU-T recommendations - TASE transport profiles |
UNI CEI EN 13757-3 : 2013 | COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 3: DEDICATED APPLICATION LAYER |
NFPA 79 : 2018 | ELECTRICAL STANDARD FOR INDUSTRIAL MACHINERY |
IEC 60870-5-103:1997 | Telecontrol equipment and systems - Part 5-103: Transmission protocols - Companion standard for the informative interface of protection equipment |
EN 61158-4-3:2014 | Industrial communication networks - Fieldbus specifications - Part 4-3: Data-link layer protocol specification - Type 3 elements |
EN 60870-5-103:1998 | Telecontrol equipment and systems - Part 5-103: Transmission protocols - Companion standard for the informative interface of protection equipment |
EN 60870-5-6:2009 | Telecontrol equipment and systems - Part 5-6: Guidelines for conformance testing for the EN 60870-5 companion standards |
EN 61375-2-1 : 2012 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 2-1: WIRE TRAIN BUS (WTB) (IEC 61375-2-1:2012) |
DIN EN 61158-4-7:2008-09 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 4-7: DATA-LINK LAYER PROTOCOL SPECIFICATION - TYPE 7 ELEMENTS |
13/30288869 DC : 0 | BS EN 13757-5 - COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 5: WIRELESS RELAYING |
BS EN 60870-5-5:1996 | Telecontrol equipment and systems. Transmission protocols Basic application functions |
BS EN 62056-7-3:2017 | Electricity metering data exchange. The DLMS/COSEM suite Wired and wireless M-Bus communication profiles for local and neighbourhood networks |
UNE-EN 13757-3:2013 | Communication systems for meters and remote reading of meters - Part 3: Dedicated application layer |
BS IEC 60870-5-6 : 2006 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-6: GUIDELINES FOR CONFORMANCE TESTING FOR THE IEC 60870-5 COMPANION STANDARDS |
12/30250727 DC | BS EN ISO 13628-6 - PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 6: SUBSEA PRODUCTION CONTROL SYSTEMS |
DIN EN 61158-4:2005-05 | DIGITAL DATA COMMUNICATION FOR MEASUREMENT AND CONTROL - FIELD BUS FOR USE IN INDUSTRIAL CONTROL SYSTEMS - PART 4: DATA LINK PROTOCOL SPECIFICATION |
DIN EN 61158-4-3:2015-09 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 4-3: DATA-LINK LAYER PROTOCOL SPECIFICATION - TYPE 3 ELEMENTS (IEC 61158-4-3:2014) |
16/30338578 DC : 0 | BS EN 13757-2 - COMMUNICATION SYSTEMS FOR METERS - PART 2: WIRED M-BUS COMMUNICATION |
BS EN 62745:2017 | Safety of machinery. Requirements for cableless control systems of machinery |
I.S. EN 62056-7-3:2017 | ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 7-3: WIRED AND WIRELESS M-BUS COMMUNICATION PROFILES FOR LOCAL AND NEIGHBOURHOOD NETWORKS |
16/30338581 DC : 0 | BS EN 13757-7 - COMMUNICATION SYSTEMS FOR METERS - PART 7: TRANSPORT AND SECURITY SERVICES |
BS ISO 22158:2011 | Input/output protocols and electronic interfaces for water meters. Requirements |
BS EN 60870-5-103:1998 | Telecontrol equipment and systems. Transmission protocols Companion standard for the informative interface of protection equipment |
12/30260040 DC : 0 | BS EN 62270 - GUIDE FOR COMPUTER-BASED CONTROL FOR HYDROELECTRIC POWER PLANT AUTOMATION |
07/30160773 DC : 0 | BS EN 13757-5 - WIRELESS METER READOUT - COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 5: RELAYING |
DD IEC/TS 60870-6-602:2001 | Telecontrol equipment and systems. Telecontrol protocols compatible with ISO standards and ITU-T recommendations TASE transport profiles |
16/30338575 DC : 0 | BS EN 13757-3 - COMMUNICATION SYSTEMS FOR METERS - PART 3: APPLICATION PROTOCOLS |
ASTM E 3137/E3137M : 2017 | Standard Specification for Heat Meter Instrumentation |
BS EN 13757-4:2013 | Communication systems for meters and remote reading of meters Wireless meter readout (Radio meter reading for operation in SRD bands) |
CSA C60044-8 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
BS EN 60044-8:2002 | Instrument transformers Electronic current transformers |
IEEE DRAFT C37.107 : D10 NOV 94 | DIGITAL PROTECTIVE RELAY INTERFACES |
I.S. EN 60870-5-101:2003 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-101: TRANSMISSION PROTOCOLS - COMPANION STANDARD FOR BASIC TELECONTROL TASKS |
ISO/IEC 14543-3-7:2007 | Information technology Home electronic system (HES) architecture Part 3-7: Media and media dependent layers Radio frequency for network based control of HES Class 1 |
CEI EN 61131-9 : 2014 | PROGRAMMABLE CONTROLLERS - PART 9: SINGLE-DROP DIGITAL COMMUNICATION INTERFACE FOR SMALL SENSORS AND ACTUATORS (SDCI) |
CEI UNI EN 13757-2 : 2011 | COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 2: PHYSICAL AND LINK LAYER |
OIML R 75-2 : 2002 | HEAT METERS - PART 2: TYPE APPROVAL TESTS AND INITIAL VERIFICATION TESTS |
EN 13757-4:2013 | Communication systems for meters and remote reading of meters - Part 4: Wireless meter readout (Radio meter reading for operation in SRD bands) |
CEI UNI EN 13757-3 : 2013 | COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 3: DEDICATED APPLICATION LAYER |
I.S. EN 60204-32:2008 | SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 32: REQUIREMENTS FOR HOISTING MACHINES |
IEC 60870-5-5:1995 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 5: Basic application functions |
06/30154990 DC : 0 | BS EN 60204-32 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 32: REQUIREMENTS FOR HOISTING MACHINES |
DD IEC TS 60870-5-601 : DRAFT JULY 2006 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-601: CONFORMANCE TEST CASES FOR THE IEC 60870-5-101 COMPANION STANDARD |
I.S. EN 61375-2-1:2012 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 2-1: WIRE TRAIN BUS (WTB) (IEC 61375-2-1:2012 (EQV)) |
IEC 62745:2017 | Safety of machinery - Requirements for cableless control systems of machinery |
PD IEC/TS 60870-5-601:2015 | Telecontrol equipment and systems Transmission protocols. Conformance test cases for the IEC 60870-5-101 companion standard |
IEEE DRAFT 1379 : D12 2000 | DRAFT RECOMMENDED PRACTICE FOR DATA COMMUNICATIONS BETWEEN REMOTE TERMINAL UNITS AND INTELLIGENT ELECTRONIC DEVICE IN A SUBSTATION |
11/30239467 DC : 0 | BS EN 13757-3 - COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 3: DEDICATED APPLICATION LAYER |
03/308772 DC : DRAFT JUNE 2003 | EN 13757-4 - COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 4: WIRELESS METER READOUT (RADIO METER READING FOR OPERATION IN THE 868-870 MHZ SRD BAND) |
CEI EN 61784-3-3 : 2012 | INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-3: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF 3 |
16/30339527 DC : 0 | BS EN 62056-7-3 ED 1.0 - ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 7-3: WIRED AND WIRELESS M-BUS COMMUNICATION PROFILES FOR LOCAL AND NEIGHBOURHOOD NETWORKS |
UNE-EN 13757-5:2016 | Communication systems for meters - Part 5: Wireless M-Bus relaying |
08/30193112 DC : 0 | BS EN 60870-5-6:2008 - TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-6: GUIDELINES FOR CONFORMANCE TESTING FOR THE IEC 60870-5 COMPANION STANDARDS |
BS 7404-5.2(1992) : 1992 AMD 8114 | TELECONTROL EQUIPMENT AND SYSTEMS - TRANSMISSION PROTOCOLS - SPECIFICATION FOR LINK TRANSMISSION PROCEDURES |
BS EN 60870-5-3:1992 | Telecontrol equipment and systems. Transmission protocols Specification for general structure of application data |
BS EN 60870-5-2:1994 | Telecontrol equipment and systems. Transmission protocols Link transmission procedures |
EN 62056-7-3:2017 | Electricity metering data exchange - The DLMS/COSEM suite - Part 7-3: Wired and wireless M-Bus communication profiles for local and neighbourhood networks |
BS EN 61158-4:2004 | Fieldbus standard for use in industrial control systems Data link protocol specification |
07/30160777 DC : 0 | BS EN 13757-6 - COMMUNICATION SYSTEMS FOR AND REMOTE READING OF METERS - PART 6: LOCAL BUS |
BS EN 61375-3-1:2012 | Electronic railway equipment. Train communication network (TCN) Multifunction Vehicle Bus (MVB) |
CAN/CSA-ISO/IEC 10192-1-04 (R2017) | Information Technology - Home Electronic System (HES) Interfaces - Part 1: Universal Interface (UI) Class 1 (Adopted ISO/IEC 10192-1:2002, first edition, 2002-08) |
NF EN 60044-8 : 2006 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSDUCERS |
IEEE DRAFT 1378 : DEC 96 | GUIDE FOR COMMISSIONING HIGH-VOLTAGE DIRECT-CURRENT CONVERTER STATIONS AND ASSOCIATED TRANSMISSION SYSTEMS |
CSA C60044-8 :2007 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
IEC TR 61334-1-2:1997 | Distribution automation using distribution line carrier systems - Part 1-2: General considerations - Guide for specification |
NF EN 60870 5 101 : 2004 AMD 1 2016 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-101: TRANSMISSION PROTOCOLS - COMPANION STANDARD FOR BASIC TELECONTROL TASKS |
DIN EN 13757-4:2014-02 | COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 4: WIRELESS METER READOUT (RADIO METER READING FOR OPERATION IN SRD BANDS) |
I.S. EN 60870-5-103:1999 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-103: TRANSMISSION PROTOCOLS - COMPANION STANDARD FOR THE INFORMATIVE INTERFACE OF PROTECTION EQUIPMENT |
I.S. EN 61158-4-7:2008 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 4-7: DATA-LINK LAYER PROTOCOL SPECIFICATION - TYPE 7 ELEMENTS |
UNI CEI EN 13757-4 : 2013 | COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 4: WIRELESS METER READOUT (RADIO METER READING FOR OPERATION IN SRD BANDS) |
ISO 22158:2011 | Input/output protocols and electronic interfaces for water meters Requirements |
IEC TR 60870-1-5:2000 | Telecontrol equipment and systems - Part 1-5: General considerations - Influence of modem transmission procedures with scramblers on the data integrity of transmission systems using the protocol IEC 60870-5 |
CEI EN 61375-2-1 : 2013 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 2-1: WIRE TRAIN BUS (WTB) |
I.S. EN 61158-4-3:2014 | INDUSTRIAL COMMUNICATION NETWORKS - FIELDBUS SPECIFICATIONS - PART 4-3: DATA-LINK LAYER PROTOCOL SPECIFICATION - TYPE 3 ELEMENTS |
CEI EN 60044-8 : 2004 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS |
15/30280758 DC : 0 | BS EN 62745 - SAFETY OF MACHINERY - GENERAL REQUIREMENTS FOR CABLELESS CONTROL SYSTEMS OF MACHINERY |
09/30205446 DC : 0 | BS EN 61375-2-1 - ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK - PART 2-1: WTB - WIRE TRAIN BUS |
BS EN 13757-5:2015 | Communication systems for meters Wireless M-Bus relaying |
PD IEC TR 60870-1-5:2000 | Influence of modem transmission procedures with scramblers on the data integrity of transmission systems using the protocol IEC 60870-5Telecontrol equipment and systems. General considerations |
BS EN 61375-2-1:2012 | Electronic railway equipment. Train communication network (TCN) Wire Train Bus (WTB) |
BS EN 61158-4-7:2008 | Industrial communication networks. Fieldbus specifications Data-link layer protocol specification. Type 7 elements |
04/19986707 DC : 0 | BS EN 1804-4 - MACHINES FOR UNDERGROUND MINES - SAFETY REQUIREMENTS FOR HYDRAULIC POWERED ROOF SUPPORTS - PART 4: ELECTRO-HYDRAULIC CONTROL SYSTEMS |
CAN/CSA-ISO/IEC 14543-3-7-07 (R2017) | Information Technology - Home Electronic System (HES) Architecture - Part 3-7: Media and Media Dependent Layers - Radio Frequency for Network Based Control of HES Class 1 (Adopted ISO/IEC 14543-3-7:2007, first edition, 2007-01) |
I.S. EN 60870-5-102:1999 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5: TRANSMISSION PROTOCOLS - SECTION 102: COMPANION STANDARD FOR THE TRANSMISSION OF INTEGRATED TOTALS IN ELECTRIC POWER SYSTEMS |
UNE-EN 13757-4:2014 | Communication systems for meters and remote reading of meters - Part 4: Wireless meter readout (Radio meter reading for operation in SRD bands) |
04/302050 DC : DRAFT JAN 2004 | ISO 13628-6 - PETROLEUM AND NATURAL GAS INDUSTRIES - DESIGN AND OPERATION OF SUBSEA PRODUCTION SYSTEMS - PART 6: SUBSEA PRODUCTION CONTROL SYSTEMS |
99/201444 DC : DRAFT MAR 1999 | IEC 61850-3 - COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTANCES - PART 3: GENERAL REQUIREMENTS |
CSA ISO/IEC 10192-1 : 2004 : R2012 | INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) INTERFACES - PART 1: UNIVERSAL INTERFACE (UI) CLASS 1 |
API 17F REDLINE : 2006 | SPECIFICATION FOR SUBSEA PRODUCTION CONTROL SYSTEMS |
I.S. EN 60870-5-6:2009 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-6: GUIDELINES FOR CONFORMANCE TESTING FOR THE EN 60870-5 COMPANION STANDARDS |
I.S. EN 13757-4:2013 | COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 4: WIRELESS METER READOUT (RADIO METER READING FOR OPERATION IN SRD BANDS) |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
IEC 61375-3-1:2012 | Electronic railway equipment - Train communication network (TCN) - Part 3-1: Multifunction Vehicle Bus (MVB) |
IEC 60870-5-6:2006 | Telecontrol equipment and systems - Part 5-6: Guidelines for conformance testing for the IEC 60870-5 companion standards |
IEC 61158-4:2003 | Digital data communications for measurement and control - Fieldbus for use in industrial control systems - Part 4: Data link protocol specification |
IEC 61375-2-1:2012 | Electronic railway equipment - Train communication network (TCN) - Part 2-1: Wire Train Bus (WTB) |
98/705686 DC : DRAFT MAR 1998 | PREN 13135-1 - CRANES - SAFETY - DESIGN - REQUIREMENTS FOR EQUIPMENT - PART 1: ELECTROTECHNICAL EQUIPMENT |
IEC 60870-5-102:1996 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 102: Companion standard for the transmission of integrated totals in electric power systems |
IEC 61131-9:2013 | Programmable controllers - Part 9: Single-drop digital communication interface for small sensors and actuators (SDCI) |
IEC 60870-5-3:1992 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 3: General structure of application data |
ISO 13628-6:2006 | Petroleum and natural gas industries Design and operation of subsea production systems Part 6: Subsea production control systems |
BS EN ISO 13628-6:2006 | Petroleum and natural gas industries. Design and operation of subsea production systems Subsea production control systems |
EN 13757-5:2015 | Communication systems for meters - Part 5: Wireless M-Bus relaying |
EN ISO 13628-6:2006 | Petroleum and natural gas industries - Design and operation of subsea production systems - Part 6: Subsea production control systems (ISO 13628-6:2006) |
PREN 13757-4 : DRAFT 2011 | COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 4: WIRELESS METER READOUT (RADIO METER READING FOR OPERATION IN SRD BANDS) |
DIN EN 13757-5:2016-02 | COMMUNICATION SYSTEMS FOR METERS - PART 5: WIRELESS M-BUS RELAYING |
BS EN 61131-9:2013 | Programmable controllers Single-drop digital communication interface for small sensors and actuators (SDCI) |
05/30133337 DC : DRAFT MAY 2005 | IEC 61375-1 - ELECTRIC RAILWAY EQUIPMENT - TRAIN BUS - PART 1: TRAIN COMMUNICATION NETWORK |
BS EN 60870-5-6:2009 | Marine energy. Wave, tidal and other water current converters Scale testing of tidal stream energy systems |
BS EN 13757-2:2004 | Communication systems for remote reading of meters Physical and link layer |
03/304144 DC : 0 | IEC 60870-5-6 ED.1.0 - TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-6: TEST PROCEDURES FOR IEC 60870-5 COMPANION STANDARDS |
13/30294110 DC : 0 | BS EN 61784-3-X ED 1.0 - INDUSTRIAL COMMUNICATION NETWORKS - PROFILES - PART 3-X: FUNCTIONAL SAFETY FIELDBUSES - ADDITIONAL SPECIFICATIONS FOR CPF X |
IEC 61784-3-3:2016 | Industrial communication networks - Profiles - Part 3-3: Functional safety fieldbuses - Additional specifications for CPF 3 |
I.S. EN 61158-4:2004 | DIGITAL DATA COMMUNICATION FOR MEASUREMENT AND CONTROL - FIELDBUS FOR USE IN INDUSTRIAL CONTROL SYSTEMS - PART 4: DATA LINK PROTOCOL SPECIFICATION |
EN 62745:2017 | Safety of machinery - Requirements for cableless control systems of machinery |
BS EN 61784-3-3:2017 | Industrial communication networks. Profiles Functional safety fieldbuses. Additional specifications for CPF 3 |
NF EN 13757-5 : 2016 | COMMUNICATION SYSTEMS FOR METERS - PART 5: WIRELESS M-BUS RELAYING |
I.S. EN 61131-9:2013 | PROGRAMMABLE CONTROLLERS - PART 9: SINGLE-DROP DIGITAL COMMUNICATION INTERFACE FOR SMALL SENSORS AND ACTUATORS (SDCI) |
IEEE C57.143-2012 | IEEE Guide for Application for Monitoring Equipment to Liquid-Immersed Transformers and Components |
IEEE 1815-2012 REDLINE | IEEE Standard for Electric Power Systems Communications-Distributed Network Protocol (DNP3) |
I.S. EN 60870-5-5:1998 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5: TRANSMISSION PROTOCOLS - SECTION 5: BASIC APPLICATION FUNCTIONS |
IEC TS 60870-5-601:2015 | Telecontrol equipment and systems - Part 5-601: Transmission protocols - Conformance test cases for the IEC 60870-5-101 companion standard |
BS EN 61158-4-3:2014 | Industrial communication networks. Fieldbus specifications Data-link layer protocol specification. Type 3 elements |
UNI CEI EN 13757-5 : 2009 | COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 5: WIRELESS RELAYING |
PREN 13757-5 : DRAFT 2013 | COMMUNICATION SYSTEMS FOR METERS AND REMOTE READING OF METERS - PART 5: WIRELESS RELAYING |
I.S. EN 61375-3-1:2012 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-1: MULTIFUNCTION VEHICLE BUS (MVB) (IEC 61375-3-1:2012 (EQV)) |
ISO/IEC 10192-1:2002 | Information technology Home Electronic System (HES) interfaces Part 1: Universal Interface (UI) Class 1 |
I.S. EN 13757-5:2015 | COMMUNICATION SYSTEMS FOR METERS - PART 5: WIRELESS M-BUS RELAYING |
IEC 62056-7-3:2017 | Electricity metering data exchange - The DLMS/COSEM suite - Part 7-3: Wired and wireless M-Bus communication profiles for local and neighbourhood networks |
IEC 60870-5-101:2003+AMD1:2015 CSV | Telecontrol equipment and systems - Part 5-101: Transmissionprotocols - Companion standard for basic telecontrol tasks |
02/203840 DC : DRAFT MAY 2002 | IEC 60204-1/ED.5.0 - SAFETY OF MACHINERY - ELECTRICAL EQUIPMENT OF MACHINES - PART 1: GENERAL REQUIREMENTS |
IEC 60204-32:2008 | Safety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines |
IEC 61158-4-7:2007 | Industrial communication networks - Fieldbus specifications - Part 4-7: Data-link layer protocol specification - Type 7 elements |
BS EN 60204-32:2008 | Safety of machinery. Electrical equipment of machines Requirements for hoisting machines |
IEC 61158-4-3:2014 | Industrial communication networks - Fieldbus specifications - Part 4-3: Data-link layer protocol specificationn - Type 3 elements |
CEN/TS 13763-27:2003 | Explosives for civil uses - Detonators and relays - Part 27: Definitions, methods and requirements for electronic initiation systems |
EN 60870-5-3:1992 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 3: General structure of application data |
EN 60870-5-5:1995 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 5: Basic application functions |
EN 60870-5-101:2003/A1:2016 | TELECONTROL EQUIPMENT AND SYSTEMS - PART 5-101: TRANSMISSION PROTOCOLS - COMPANION STANDARD FOR BASIC TELECONTROL TASKS |
EN 60204-32:2008 | Safety of machinery - Electrical equipment of machines - Part 32: Requirements for hoisting machines |
EN 60870-5-102:1996 | Telecontrol equipment and systems - Part 5: Transmission protocols - Section 102: Companion standard for the transmission of integrated totals in electric power systems |
EN 61158-4:2004 | Digital data communication for measurement and control - Fieldbus for use in industrial control systems - Part 4: Data link protocol specification |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
EN 61158-4-7:2008 | Industrial communication networks - Fieldbus specifications - Part 4-7: Data-link layer protocol specification - Type 7 elements |
EN 61375-3-1 : 2012 | ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-1: MULTIFUNCTION VEHICLE BUS (MVB) (IEC 61375-3-1:2012) |
EN 61131-9 : 2013 | Programmable controllers - Part 9: Single-drop digital communication interface for small sensors and actuators (SDCI) |