IEC 60861:2006
Current
The latest, up-to-date edition.
Equipment for monitoring of radionuclides in liquid effluents and surface waters
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
08-21-2006
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Classification of equipment
5 Equipment design
5.1 Measurement and indication characteristics
5.2 Reliability
5.3 Sampling assembly
5.4 Detection assembly
5.5 Control assembly
5.6 Measurement assembly
5.7 Alarm assembly
5.8 Indication facilities
5.9 Facilities for operational testing
5.10 Installation and maintenance facilities
5.11 Ambient ionizing radiation protection devices
5.12 User safety
5.13 Electromagnetic compatibility
5.14 Power supply
6 Test procedures
6.1 General
6.2 Tests performed under standard test conditions
6.3 Tests performed with variation of influence quantities
6.4 Metrological characteristics
6.5 Test sources
7 Radiation performance tests
7.1 Reference response
7.2 Sensitivity and relative response of the equipment
for a solid source
7.3 Linearity
7.4 Repeatability of the equipment
7.5 Reproducibility of results of measurements
7.6 Response time
7.7 Uniformity of the protective screens for the beta
detector
7.8 Overload test
7.9 Response to other artificial radionuclides
7.10 Response to [222]Rn progeny dissolved in water
7.11 Response to ambient gamma radiation
7.12 Influence of materials in suspension in liquid on
activity measurement
8 Liquid circuit performance tests
8.1 General
8.2 Flow-rate stability
8.3 Cleaning efficiency
9 Electrical performance tests
9.1 Warm-up time - Detection and measurement assemblies
9.2 Power-supply variations
9.3 Power-supply transient effects
9.4 Alarm-trip stability
9.5 Alarm-trip range
9.6 Fault alarm
10 Environmental performance test
10.1 Ambient temperature
10.2 Relative humidity
10.3 External electromagnetic immunity and electrostatic
discharge
10.4 Electromagnetic emission
11 Type test report
12 Certificate
13 Operation and maintenance manual
Annex A (informative) Guidance for use with radioactive water
monitors
Annex B (informative) Realization of an artificial effluent
for testing
Defines technical requirements for equipment for monitoring of alpha-, beta- or gamma-emitting radionuclides in liquid effluents and surface waters, provides general guidance as to the possible detection capability of such equipment and indicates when and where its uses may be practicable.
Committee |
TC 45/SC 45B
|
DevelopmentNote |
Supersedes IEC 61311 (08/2006) Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
81
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
SAC GB/T 10253 : 2001 | Identical |
BS IEC 60861 : 2006 | Identical |
DIN EN 60861 : 2008 | Identical |
VDE 0493-4-2 : 2008 | Identical |
UNE-EN 60861:2008 | Identical |
UNE 21745:1992 | Identical |
NEN 10861 : 1988 | Identical |
PNE-prEN 60861 | Identical |
CEI 45-45 : 1997 | Identical |
16/30324061 DC : 0 | BS IEC 61504 ED2.0 - NUCLEAR FACILITIES INSTRUMENTATION AND CONTROL SYSTEMS IMPORTANT TO SAFETY - CENTRALIZED SYSTEMS FOR CONTINUOUS MONITORING OF RADIATION AND/OR LEVELS OF RADIOACTIVITY |
BS IEC 60532:2010 | Radiation protection instrumentation. Installed dose rate meters, warning assemblies and monitors. X and gamma radiation of energy between 50 keV and 7 MeV |
CSA N288.5 : 2011 : R2016 | EFFLUENT MONITORING PROGRAMS AT CLASS 1 NUCLEAR FACILITIES AND URANIUM MINES AND MILLS |
BS IEC 62705:2014 | Nuclear power plants. Instrumentation and control important to safety. Radiation monitoring systems (RMS): Characteristics and lifecycle |
13/30249610 DC : 0 | BS EN 62705 ED 1.0 - NUCLEAR POWER PLANTS - INSTRUMENTATION AND CONTROL IMPORTANT TO SAFETY - RADIATION MONITORING SYSTEMS (RMS) CHARACTERISTICS AND TEST METHODS |
IEC 61311:1995 | Radiation protection instrumentation - Equipment for continuously monitoring beta and gamma emitting radionuclides in liquid effluents or in surface waters |
CSA N288.5 : 2011 | EFFLUENT MONITORING PROGRAMS AT CLASS 1 NUCLEAR FACILITIES AND URANIUM MINES AND MILLS |
IEC 61504:2017 | Nuclear facilities - Instrumentation and control systems important to safety - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
IEC 60951-1:2009 | Nuclear power plants - Instrumentation important to safety - Radiation monitoring for accident and post-accident conditions - Part 1: General requirements |
BS IEC 60951-1:2009 | Nuclear power plants. Instrumentation important to safety. Radiation monitoring for accident and post-accident conditions General requirements |
BS IEC 60768:2009 | Nuclear power plants. Instrumentation important to safety. Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions |
07/30172925 DC : 0 | BS IEC 60951-1 - NUCLEAR POWER PLANTS - INSTRUMENTATION IMPORTANT TO SAFETY - RADIATION MONITORING SYSTEM FOR ACCIDENT AND POST ACCIDENT CONDITIONS - PART 1: GENERAL REQUIREMENTS |
BS IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity General requirements |
BS IEC 61504:2017 | Nuclear facilities. Instrumentation and control systems important to safety. Centralized systems for continuous monitoring of radiation and/or levels of radioactivity |
IEC 62705:2014 | Nuclear power plants - Instrumentation and control important to safety - Radiation monitoring systems (RMS): Characteristics and lifecycle |
IEC 60768:2009 | Nuclear power plants - Instrumentation important to safety - Equipment for continuous in-line or on-line monitoring of radioactivity in process streams for normal and incident conditions |
IEC 60532:2010 | Radiation protection instrumentation - Installed dose rate meters, warning assemblies and monitors - X and gamma radiation of energy between 50 keV and 7 MeV |
IEC 61559-1:2009 | Radiation protection instrumentation in nuclear facilities - Centralized systems for continuous monitoring of radiation and/or levels of radioactivity - Part 1: General requirements |
IEC 60038:2009 | IEC standard voltages |
IEC 60050-394:2007 | International Electrotechnical Vocabulary (IEV) - Part 394: Nuclear instrumentation - Instruments, systems, equipment and detectors |
IEC 61187:1993 | Electrical and electronic measuring equipment - Documentation |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60068-2-38:2009 | Environmental testing - Part 2-38: Tests - Test Z/AD: Composite temperature/humidity cyclic test |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
ISO 10012:2003 | Measurement management systems — Requirements for measurement processes and measuring equipment |
IEC 61000-6-4:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments |
IEC 61010-1:2010+AMD1:2016 CSV | Safety requirements for electrical equipment for measurement, control, and laboratory use - Part 1: General requirements |
IEC 60050-393:2003 | International Electrotechnical Vocabulary (IEV) - Part 393: Nuclear instrumentation - Physical phenomena and basic concepts |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.