• Shopping Cart
    There are no items in your cart

IEC 60811-2-1:1998+AMD1:2001 CSV

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Common test methods for insulating and sheathing materials of electric and optical cables - Part 2-1: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

03-12-2012

Language(s)

English - French

Published date

11-15-2001

US$84.00
Excluding Tax where applicable

FOREWORD
1 General
   1.1 Scope
   1.2 Normative references
2 Test values
3 Applicability
4 Type tests and other tests
5 Pre-conditioning
6 Test temperature
7 Median value
8 Ozone resistance test
   8.1 Test method
   8.2 Determination of ozone concentration
9 Hot set test
   9.1 Sampling and preparation of test pieces and
        determination of their cross sectional area
   9.2 Test apparatus
   9.3 Procedure
   9.4 Evaluation of results
10 Mineral oil immersion test for sheaths
   10.1 Sampling and preparation of the test pieces
   10.2 Determination of the cross-sectional area of the
        test piece
   10.3 Oil to be used
   10.4 Procedure
   10.5 Determination of mechanical properties
   10.6 Expression of results

Specifies the test methods to be used for testing polymericinsulating and sheathing material of electric cables for powerdistribution and telecommunications including cables used onships.Gives the methods for the ozone resistance test, hot set test andmineral oil immersion test, which apply to elastomeric compounds.This consolidated version consists of the second edition (1998) and its amendment 1 (2001). Therefore, no need to order amendment inaddition to this publication.

Committee
TC 20
DevelopmentNote
Also numbered as BS EN 60811-2.1 (09/2002) Supersedes IEC 60538 AND IEC 60540 (07/2004)
DocumentType
Standard
Pages
23
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

I.S. EN 60811-404:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 404: MISCELLANEOUS TESTS - MINERAL OIL IMMERSION TESTS FOR SHEATHS (IEC 60811-404:2012 (EQV))
05/30128938 DC : DRAFT FEB 2005 IEC 61138 ED.3 - CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
CEI 18-49 : 2013 ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS
BS EN 50382-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
BS EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables General introduction
BS EN 50306-2:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core cables
BS EN 60811-403:2012 Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Ozone resistance test on cross-linked compounds
NF ISO 4141-1 : 2000 ROAD VEHICLES - MULTICORE CONNECTING CABLES - PART 1: TEST METHODS AND REQUIREMENTS FOR BASIC PERFORMANCE SHEATHED CABLES
BS EN 50363-2-2:2005 Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric covering compounds
BS 7933-2:2007 Electric cables. Accessories. Material characterisation Fingerprinting and type tests for heat shrinkable components for low voltage applications
NFC 33 009-2 : 2008 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERIZATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS
BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
NF EN 61138 : 2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
BS EN 50363-9-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous insulating compounds. Cross-linked polyvinyl chloride (XLPVC)
05/30107058 DC : DRAFT JAN 2005 ISO 14572 - ROAD VEHICLES - ROUND, SCREENED AND UNSCREENED, 60 V AND 600 V MULTI-CORE SHEATHED CABLES - TEST METHODS AND REQUIREMENTS FOR BASIC AND HIGH PERFORMANCE CABLES
I.S. EN 60811-403:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 403: MISCELLANEOUS TESTS - OZONE RESISTANCE TEST ON CROSS-LINKED COMPOUNDS (IEC 60811-403:2012 (EQV))
UNE-ISO 6722-1:2013 Road vehicles. 60 V and 600 V single-core cables. Part 1: Dimensions, test methods and requirements for copper conductor cables
CEI EN 50525-2-22 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
I.S. EN 50264-3-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
I.S. EN 50363-0:2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW-VOLTAGE ENERGY CABLES - PART 0: GENERAL INTRODUCTION
I.S. EN 50363-10-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-2: MISCELLANEOUS SHEATHING COMPOUNDS - THERMOPLASTIC POLYURETHANE
I.S. EN 50264-3-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
HD 631.2 : 2007 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS
BS EN 60811-1-1:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Measurement of thickness and overall dimensions. Tests for determining the mechanical properties - Section 1: Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
I.S. EN 50363-7:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 7: HALOGEN-FREE, THERMOPLASTIC INSULATING COMPOUNDS
I.S. EN 50290-2-26:2002 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
I.S. EN 50363-2-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS
IEC 61230:2008 Live working - Portable equipment for earthing or earthing and short-circuiting
UNE-ISO 4141-1:2016 Road vehicles. Multi-core connecting cables. Part 1: Test methods and requirements for basic performance sheathed cables
EN 50290-2-26 : 2002 AMD 1 2007 COMMUNICATION CABLES - PART 2-26: COMMON DESIGN RULES AND CONSTRUCTION - HALOGEN FREE FLAME RETARDANT INSULATION COMPOUNDS
IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (<em>U</em><sub>m</sub> = 170 kV) up to 500 kV (<em>U</em><sub>m</sub> = 550 kV) - Test methods and requirements
EN 50363-2-1 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-1: CROSS-LINKED ELASTOMERIC SHEATHING COMPOUNDS
EN 50363-8 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS
EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
EN 61138:2007 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
EN 60811-404:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
EN 50363-10-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-1: Miscellaneous sheathing compounds - Cross-linked polyvinyl chloride (XLPVC)
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
EN 50363-9-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 9-1: Miscellaneous insulating compounds - Cross-linked polyvinyl chloride (XLPVC)
EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
EN 50363-6 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS
EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
EN 50363-7:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 7: Halogen-free, thermoplastic insulating compounds
UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
05/30133180 DC : 0 EN 50382-1 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
08/30159870 DC : DRAFT APR 2008 BS EN 60800 - HEATING CABLES WITH A RATED VOLTAGE OF 300/500 V FOR COMFORT HEATING AND PREVENTION OF ICE FORMATION
BS EN 60811-404:2012 Electric and optical fibre cables. Test methods for non-metallic materials Miscellaneous tests. Mineral oil immersion tests for sheaths
CEI EN 50306-4 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED
03/301511 DC : DRAFT JAN 2003 ISO 4141-1 - ROAD VEHICLES - MULTICORE CONNECTING CABLES - PART 1: TEST METHODS AND REQUIREMENTS FOR BASIC PERFORMANCE SHEATHED CABLES
BS ISO 6722-1:2011 Road vehicles. 60 V and 600 V single-core cables Dimensions, test methods and requirements for copper conductor cables
I.S. EN 61138:2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
NF EN 50306-4 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 4: MULTICORE AND MULTIPAIR CABLES STANDARD WALL SHEATHED
BS EN 50264-2-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Single core cables
BS EN 50306-3:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
05/30102442 DC : DRAFT JAN 2005 ISO 6722 - ROAD VEHICLES - 60 V AND 600 V SINGLE CORE CABLES - DIMENSIONS, TEST METHODS AND REQUIREMENTS
NF EN 50396 : 2005 AMD 1 2012 NON ELECTRICAL TEST METHODS FOR LOW VOLTAGE ENERGY CABLES
UNE-EN 60811-404:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 404: Miscellaneous tests - Mineral oil immersion tests for sheaths
I.S. EN 50264-2-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
I.S. EN 50363-10-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 10-1: MISCELLANEOUS SHEATHING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC)
I.S. HD 631.2:2007 ELECTRIC CABLES - ACCESSORIES - MATERIAL CHARACTERISATION - PART 2: FINGERPRINTING AND TYPE TESTS FOR HEAT SHRINKABLE COMPONENTS FOR LOW VOLTAGE APPLICATIONS
NF EN 61230 : 2009 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
NF EN 50264-3-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
UNE-EN 50525-3-21:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-21: Cables with special fire performance - Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
DEFSTAN 02-526/2(2008) : 2008 REQUIREMENTS FOR CABLES ELECTRIC, ELASTOMERIC, LIMITED FIRE HAZARD SHEATHED FOR GENERAL SERVICES
IEC 60840:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements
I.S. EN 50363-5:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
EN 50306-1:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 1: General requirements
I.S. EN 60811-507:2012 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 507: MECHANICAL TESTS - HOT SET TEST FOR CROSS-LINKED MATERIALS (IEC 60811-507:2012 (EQV))
10/30196577 DC : 0 BS ISO 6722-1 - ROAD VEHICLES - 60 V AND 600 V SINGLE-CORE CABLES - PART 1: DIMENSIONS, TEST METHODS AND REQUIREMENTS FOR COPPER CONDUCTOR CABLES
BS EN 50306-1:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall General requirements
BS EN 50382-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS ISO 4141-1:2005 Road vehicles. Multi-core connecting cables Test methods and requirements for basic performance sheathed cables
I.S. EN 50363-4-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-1: PVC SHEATHING COMPOUNDS
BS EN 50264-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance General requirements
BS EN 50290-2-26:2002 Communication cables Common design rules and construction. Halogen free flame retardant insulation compounds
BS EN 50525-3-21:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Flexible cables with halogen-free crosslinked insulation, and low emission of smoke
CEI EN 50264-2-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
BS EN 50264-3-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Multicore cables
BS 6469-1.1(1992) : 1992 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - METHODS OF TEST FOR GENERAL APPLICATION - MEASUREMENT OF THICKNESS & OVERALL DIMENSIONS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
NF EN 50306-3 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED
CEI EN 50306-2 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES
BS ISO 6722:2006 Road vehicles. 60 V and 600 V single-core cables. Dimensions, test methods and requirements
CEI EN 50264-2-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
UNE-EN 50264-2-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
I.S. EN 50382-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
CEI EN 60811-403 : 2014 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 403: MISCELLANEOUS TESTS - OZONE RESISTANCE TESTS ON CROSS-LINKED COMPOUNDS
NF EN 50306-2 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 2: SINGLE CORE CABLES
I.S. EN 50363-3:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS
I.S. EN 50264-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
IEC 60245-8:1998+AMD1:2003+AMD2:2011 CSV Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 8: Cords for applications requiring high flexibility
CEI EN 50264-3-2 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
IEC 60245-4:2011 Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 4: Cords and flexible cables
NF EN 50382-2 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
IEC 60800:2009 Heating cables with a rated voltage of 300/500 V for comfort heating and prevention of ice formation
I.S. EN 50363-6:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 6: HALOGEN-FREE, CROSS-LINKED SHEATHING COMPOUNDS
IEC TS 62100:2004 Cables for aeronautical ground lighting primary circuits
IEC 60092-351:2004 Electrical installations in ships - Part 351: Insulating materials for shipboard and offshore units, power, control, instrumentation, telecommunication and data cables
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
UNE-EN 50264-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 1: General requirements
CEI EN 50306-3 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 3: SINGLE CORE AND MULTICORE CABLES (PAIRS, TRIPLES AND QUADS) SCREENED AND THIN WALL SHEATHED
BS EN 60811-507:2012 Electric and optical fibre cables. Test methods for non-metallic materials Mechanical tests. Hot set test for cross-linked materials
BS EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables Cross-linked elastomeric insulating compounds
BS EN 50525-2-22:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. High flexibility braided cables with crosslinked elastomeric insulation
UNE-EN 60811-507:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials
UNE-EN 50264-3-1:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
BS EN 61230:2008 Live working. Portable equipment for earthing or earthing and short-circuiting
ISO 6722-1:2011 Road vehicles — 60 V and 600 V single-core cables — Part 1: Dimensions, test methods and requirements for copper conductor cables
BS EN 50363-4-1:2005 Insulating, sheathing and covering materials for low voltage energy cables PVC sheathing compounds
CEI EN 50306-1 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
BS EN 50264-3-1:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation with reduced dimensions. Single core cables
BS EN 50363-4-2:2005 Insulating, sheathing and covering materials for low voltage energy cables PVC covering compounds
CEI EN 50264-3-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
SAE J 1678 : 2015 LOW VOLTAGE ULTRA THIN WALL PRIMARY CABLE
08/30188788 DC : 0 BS EN 50525-2-22 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
05/30136249 DC : 0 EN 50264-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
BS EN 50306-4:2002 Railway applications. Railway rolling stock cables having special fire performance. Thin wall Multicore and multipair cables standard wall sheathed
05/30133183 DC : 0 EN 50382-2 - RAILWAY APPLICATIONS - HIGH TEMPERATURE POWER CABLES FOR RAILWAY ROLLING STOCK AND HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREE C
CEI EN 50264-1 : 2009 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
07/30170224 DC : DRAFT AUG 2007 BS EN 61230 - LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
IEC 60227-7:1995+AMD1:2003+AMD2:2011 CSV Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 7: Flexible cables screened and unscreened with two or more conductors
BS EN 50363-10-1:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Cross-linked polyvinyl chloride (XLPVC)
BS EN 50363-7:2005 Insulating, sheathing and covering materials for low voltage energy cables Halogen-free, thermoplastic insulating compounds
PREN 50525-2-22 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
CEI EN 50525-3-21 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
I.S. EN 60811-1-1:1997 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
I.S. EN 50363-9-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 9-1: MISCELLANEOUS INSULATING COMPOUNDS - CROSS-LINKED POLYVINYL CHLORIDE (XLPVC)
I.S. EN 50382-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
I.S. EN 50363-4-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 4-2: PVC COVERING COMPOUNDS
NF EN 50264-2-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
I.S. EN 50363-1:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 1: CROSS-LINKED ELASTOMERIC INSULATING COMPOUNDS
I.S. EN 50363-2-2:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 2-2: CROSS-LINKED ELASTOMERIC COVERING COMPOUNDS
CEI EN 60811-404 : 2014 ELECTRIC AND OPTICAL FIBRE CABLES - TEST METHODS FOR NON-METALLIC MATERIALS - PART 404: MISCELLANEOUS TESTS - MINERAL OIL IMMERSION TESTS FOR SHEATHS
IEC 61138:2007 Cables for portable earthing and short-circuiting equipment
IEC 60245-5:1994 Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 5: Lift cables
I.S. EN 61230:2008 LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING
EN 50306-2:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 2: Single core cables
EN 50306-3:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 3: Single core and multicore cables (pairs, triples and quads) screened and thin wall sheathed
IEC 60811-403:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds
EN 50306-4:2002 Railway applications - Railway rolling stock cables having special fire performance - Thin wall - Part 4: Multicore and multipair cables standard wall sheathed
EN 50363-3 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 3: PVC INSULATING COMPOUNDS
EN 50363-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 1: Cross-linked elastomeric insulating compounds
EN 50525-2-22:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
I.S. EN 50525-2-22:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-22: CABLES FOR GENERAL APPLICATIONS - HIGH FLEXIBILITY BRAIDED CABLES WITH CROSSLINKED ELASTOMERIC INSULATION
BS EN 50363-10-2:2005 Insulating, sheathing and covering materials for low-voltage energy cables Miscellaneous sheathing compounds. Thermoplastic polyurethane
UNE-EN 60811-403:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds
04/30114758 DC : 0 IEC 60092-350 ED.3 - ELECTRICAL INSTALLATION IN SHIP - PART 350: SHIPBOARD POWER CABLES - GENERAL CONSTRUCTION AND TEST REQUIREMENTS
08/30188836 DC : 0 BS EN 50525-3-21 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
ISO 4141-1:2005 Road vehicles Multi-core connecting cables Part 1: Test methods and requirements for basic performance sheathed cables
I.S. EN 50525-3-21:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
UNE-EN 50525-2-22:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-22: Cables for general applications - High flexibility braided cables with crosslinked elastomeric insulation
ISO 6722:2006 Road vehicles 60 V and 600 V single-core cables Dimensions, test methods and requirements
I.S. EN 50264-2-2:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - MULTICORE CABLES
05/30136253 DC : 0 EN 50264-2-1 - RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
I.S. HD 605:2008 ELECTRIC CABLES - ADDITIONAL TEST METHODS
03/318201 DC : DRAFT NOV 2003 IEC 60502-2, ED.2 - POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 1 KV (UM = 1,2 KV) UP TO 30 KV (UM = 36 KV) - PART 2: CABLES FOR RATED VOLTAGES FROM 6 KV (UM = 7,2 KV) UP TO 30 KV (UM = 36 KV)
BS EN 61138:1998 Cables for portable earthing and short-circuiting equipment
BIS IS/ISO 6722 : 2006 ROAD VEHICLES - 60 V AND 600 V SINGLE-CORE CABLES - DIMENSIONS, TEST METHODS AND REQUIREMENTS
NF EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
UNE-EN 50264-2-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
NF EN 50264-3-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-2: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - MULTICORE CABLES
SAE J1128_201512 LOW VOLTAGE PRIMARY CABLE
UNE-EN 61230:2011 Live working - Portable equipment for earthing or earthing and short-circuiting
I.S. EN 50363-8:2005 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 8: HALOGEN-FREE, THERMOPLASTIC SHEATHING COMPOUNDS
SAE J 1127 : 2015 LOW VOLTAGE BATTERY CABLE
NF EN 50306-1 : 2003 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK CABLES HAVING SPECIAL FIRE PERFORMANCE - THIN WALL - PART 1: GENERAL REQUIREMENTS
NF EN 50264-2-1 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION - SINGLE CORE CABLES
PREN 50525-3-21 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
UNE-EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables -- Part 0: General introduction
IEC 60502-1:2004+AMD1:2009 CSV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV(<em>U</em><sub>m</sub> = 36 kV) - Part 1: Cables for rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV)
IEC 60245-1:2003+AMD1:2007 CSV Rubber insulated cables - Rated voltages up to and including 450/750 V - Part 1: General requirements
EN 50363-4-2:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 4-2: PVC covering compounds
EN 50363-2-2:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 2-2: Cross-linked elastomeric covering compounds
EN 60811-403:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 403: Miscellaneous tests - Ozone resistance test on cross-linked compounds
EN 50363-10-2:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 10-2: Miscellaneous sheathing compounds - Thermoplastic polyurethane
EN 50363-0:2011 Insulating, sheathing and covering materials for low-voltage energy cables - Part 0: General introduction
EN 50264-2-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-2: Cables with crosslinked elastomeric insulation - Multicore cables
EN 50264-3-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-1: Cables with crosslinked elastomeric insulation with reduced dimensions - Single core cables
EN 50382-2:2008/A1:2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
EN 50363-5 : 2005 AMD 1 2011 INSULATING, SHEATHING AND COVERING MATERIALS FOR LOW VOLTAGE ENERGY CABLES - PART 5: HALOGEN-FREE, CROSS-LINKED INSULATING COMPOUNDS
EN 50363-4-1:2005 Insulating, sheathing and covering materials for low voltage energy cables - Part 4-1: PVC sheathing compounds
EN 50525-3-21:2011/AC:2013 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-21: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE CROSSLINKED INSULATION, AND LOW EMISSION OF SMOKE
EN 60811-507:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials

IEC 60811-1-2:1985 Common test methods for insulating and sheathing materials of electric cables - Part 1: Methods for general application - Section Two: Thermal ageing methods
EN 60811-1-2:1995/A2:2000 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - THERMAL AGEING METHODS
IEC 60811-1-1:1993+AMD1:2001 CSV Common test methods for insulating and sheathing materials of electric cables and optical cables - Part 1-1: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
EN 60811-1-1:1995/A1:2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING MECHANICAL PROPERTIES
ISO 1817:2015 Rubber, vulcanized or thermoplastic Determination of the effect of liquids

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.