IEC 60745-2-9:2003+AMD1:2008 CSV
Current
The latest, up-to-date edition.
Hand-held motor-operated electric tools - Safety - Part 2-9: Particular requirements for tappers
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French, Spanish, Castilian
06-25-2008
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General conditions for the tests
7 Classification
8 Marking and instructions
9 Protection against access to live parts
10 Starting
11 Input and current
12 Heating
13 Leakage current
14 Moisture resistance
15 Electric strength
16 Overload protection of transformers and associated
circuits
17 Endurance
18 Abnormal operation
19 Mechanical hazards
20 Mechanical strength
21 Construction
22 Internal wiring
23 Components
24 Supply connection and external flexible cords
25 Terminals for external conductors
26 Provision for earthing
27 Screws and connections
28 Creepage distances, clearances and distances
through insulation
29 Resistance to heat, fire and tracking
30 Resistance to rusting
31 Radiation, toxicity and similar hazards
Annexes
Annex K (normative) Battery tools and battery packs
Annex L (normative) Battery tools and battery packs
provided with mains connection or non-isolated
sources
Bibliography
Deals with the safety of tools which the rated voltage is not more than 250 V for single-phase a.c. or d.c. tools and 440 V for three-phase a.c. tools. Supplements or modifies the corresponding clauses of IEC 60745-1 This consolidated version consists of the second edition (2003) and its amendment 1 (2008). Therefore, no need to order amendment in addition to this publication.
Committee |
TC 116
|
DevelopmentNote |
To be read in conjunction with IEC 60745-1. (06/2008) Stability Date: 2019. (11/2017)
|
DocumentType |
Standard
|
Pages |
17
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
NEN EN IEC 60745-2-9 : 2009 | Identical |
I.S. EN 60745-2-9:2009 | Identical |
PN EN 60745-2-9 : 2009 | Identical |
SAC GB 3883.9 : 2005 | Identical |
DIN EN 60745-2-9 : 2010 | Identical |
NF EN 60745 2-9 : 2010 | Identical |
UNE-EN 60745-2-9:2010 | Identical |
GOST IEC 60745-2-9 : 2011 | Identical |
AS/NZS 60745.2.9:2009 | Identical |
VDE 0740-2-9 : 2016 COR 1 2017 | Identical |
NBN EN 60745 2-9 : 2010 | Identical |
JIS C 9745-2-9:2009 | Identical |
CSA C22.2 No. 60745.2.9 : 2004 : INC : AMD 1 : 2009 : R2013 | Identical |
GOST R IEC 60745-2-9 : 2010 | Identical |
CSA C22.2 No. 60745.2.9 : 2004 | Identical |
VDE 0740-209 : 1996 | Identical |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
ISO 1463:2003 | Metallic and oxide coatings Measurement of coating thickness Microscopical method |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.