• There are no items in your cart

IEC 60601-2-44:2009+AMD1:2012+AMD2:2016 CSV

Current

Current

The latest, up-to-date edition.

Medical electrical equipment - Part 2-44: Particular requirements for the basic safety and essential performance of X-ray equipment for computed tomography

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

03-31-2016

US$696.00
Excluding Tax where applicable

IEC 60601-2-44:2009+A1:2012+A2:2016 applies to the basic safety and essential performance of CT scanners. The scope of IEC 60601-2-44:2009 is limited to CT scanners intended to be used for both head and body characterised by an enclosure of the X-ray source(s) and imaging detector(s) in a common protective cover in the shape of a toroid. It includes safety requirements for the X-ray generators used in CT scanners, including those where high-voltage generators are integrated with an X-ray tube assembly. This edition constitutes a technical revision primarily related to radiation protection and control. The contents of the corrigendum of May 2010 have been included in this copy. This consolidated version consists of the third edition (2009), its amendment 1 (2012) and its amendment 2 (2016). Therefore, there is no need to order the amendments in addition to this publication.

Committee
TC 62/SC 62B
DevelopmentNote
Supersedes IEC 60601-2-32. (11/2012) Stability date: 2017. (04/2016)
DocumentType
Standard
Pages
276
PublisherName
International Electrotechnical Committee
Status
Current
Supersedes

IEC 60601-2-68:2014 Medical electrical equipment - Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
06/30107360 DC : 0 IEC 60601-1-3 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD - RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT
EN 60601-2-63:2015 Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment
EN 60601-2-65:2013 Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment
I.S. EN 61223-2-6:2007 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-6: CONSTANCY TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
EN 60601-1-2:2015 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
NF EN 61223-3-5 : 2005 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-5: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
12/30159217 DC : 0 BS EN 60601-1-2 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES - REQUIREMENTS AND TESTS
BS EN 61223-3-5:2004 Evaluation and routine testing in medical imaging departments Acceptance tests - Imaging performance of computed tomography X-ray equipment
ANSI/AAMI/IEC 60601-1-2:2014 MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES - REQUIREMENTS AND TESTS
BS EN 60601-2-63:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment
BS EN 60601-2-65:2013 Medical electrical equipment Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment
BS EN 60601-2-43:2010 Medical electrical equipment Particular requirements for basic safety and essential performance of X-ray equipment for interventional procedures
I.S. EN ISO 11073-10406:2012 HEALTH INFORMATICS - PERSONAL HEALTH DEVICE COMMUNICATION - PART 10406: DEVICE SPECIALIZATION - BASIC ELECTROCARDIOGRAPH (ECG) (1- TO 3-LEAD ECG) (ISO/IEEE 11073-10406:2012)
IEC TR 61948-3:2018 Nuclear medicine instrumentation - Routine tests - Part 3: Positron emission tomographs
I.S. EN 60601-2-65:2013 MEDICAL ELECTRICAL EQUIPMENT - PART 2-65: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF DENTAL INTRA-ORAL X-RAY EQUIPMENT (IEC 60601-2-65:2012 (EQV))
IEC 60601-2-43:2010+AMD1:2017 CSV Medical electrical equipment - Part 2-43: Particular requirements for the basic safety and essential performance of X-ray equipment for interventional procedures
IEC TR 60788:2004 Medical electrical equipment - Glossary of defined terms
ISO/IEEE 11073-10418:2014 Health informatics — Personal health device communication — Part 10418: Device specialization — International Normalized Ratio (INR) monitor
IEC 60601-2-63:2012+AMD1:2017 CSV Medical electrical equipment - Part 2-63: Particular requirements for the basic safety and essential performance of dental extra-oral X-ray equipment
I.S. EN 60601-1-3:2008 MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT
EN 60601-1-3 : 2008 AMD 11 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008/A1:2013)
OVE/ONORM EN 61223-3-5 : 2005 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-5: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
NEMA XR 25 : 2010 COMPUTED TOMOGRAPHY DOSE CHECK
NEMA XR 28 : 2013 SUPPLEMENTAL REQUIREMENTS FOR USER INFORMATION AND SYSTEM FUNCTION RELATED TO DOSE IN CT
NEMA PS3.3 : 2017A DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE (DICOM) - PART 3: INFORMATION OBJECT DEFINITIONS
NEMA PS 3.16 : 2017A DIGITAL IMAGING AND COMMUNICATIONS IN MEDICINE (DICOM) - PART 16: CONTENT MAPPING RESOURCE
03/304751 DC : DRAFT APR 2003 IEC 61223-3-5 ED.1.0 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-5: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
BS EN 60601-2-68:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
BS EN ISO 11073-10418:2014 Health informatics. Personal health device communication Device specialization. International Normalized Ratio (INR) monitor
I.S. EN 60601-2-63:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-63: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF DENTAL EXTRAORAL X-RAY EQUIPMENT
EN 60601-2-43:2010/A1:2018 MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES (IEC 60601-2-43:2010/A1:2017)
PD IEC/TR 60601-4-3:2015 Medical electrical equipment Guidance and interpretation. Considerations of unaddressed safety aspects in the third edition of IEC 60601-1 and proposals for new requirements
CSA C22.2 No. 60601-2-68 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-68: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY-BASED IMAGE-GUIDED RADIOTHERAPY EQUIPMENT FOR USE WITH ELECTRON ACCELERATORS, LIGHT ION BEAM THERAPY EQUIPMENT AND RADIONUCLIDE BEAM THERAPY EQUIPMENT
I.S. EN 60601-1-2:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES - REQUIREMENTS AND TESTS
IEC 61223-3-5:2004 Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment
BS EN 60601-1-2:2015 Medical electrical equipment General requirements for basic safety and essential performance. Collateral Standard. Electromagnetic disturbances. Requirements and tests
PD IEC TR 60788:2004 Medical electrical equipment. Glossary of defined terms
CSA C22.2 No. 60601-2-63 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-63: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF DENTAL EXTRA-ORAL X-RAY EQUIPMENT
EN 60601-2-68:2015 Medical electrical equipment - Part 2-68: Particular requirements for the basic safety and essential performance of X-ray-based image-guided radiotherapy equipment for use with electron accelerators, light ion beam therapy equipment and radionuclide beam therapy equipment
I.S. EN ISO 11073-10418:2014 HEALTH INFORMATICS - PERSONAL HEALTH DEVICE COMMUNICATION - PART 10418: DEVICE SPECIALIZATION: INTERNATIONAL NORMALIZED RATIO (INR) MONITOR (ISO/IEEE 11073-10418:2014, CORRECTED VERSION 2014-05-01)
I.S. EN 60601-2-68:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-68: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY-BASED IMAGE-GUIDED RADIOTHERAPY EQUIPMENT FOR USE WITH ELECTRON ACCELERATORS, LIGHT ION BEAM THERAPY EQUIPMENT AND RADIONUCLIDE BEAM THERAPY EQUIPMENT
I.S. EN 61223-3-5:2004 EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 3-5: ACCEPTANCE TESTS - IMAGING PERFORMANCE OF COMPUTED TOMOGRAPHY X-RAY EQUIPMENT
I.S. EN 60601-2-43:2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES
IEC 60601-2-65:2012+AMD1:2017 CSV Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intra-oral X-ray equipment
IEC 61223-2-6:2006 Evaluation and routine testing in medical imaging departments ­ - Part 2­-6: Constancy tests ­ imaging performance of computed tomography X-ray equipment
IEC 60601-1-3:2008+AMD1:2013 CSV Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
IEC 60601-1-2:2007 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests
ISO/IEEE 11073-10406:2012 Health informatics — Personal health device communication — Part 10406: Device specialization — Basic electrocardiograph (ECG) (1- to 3-lead ECG)
BS EN 60601-1-3 : 2008 MEDICAL ELECTRICAL EQUIPMENT - PART 1-3: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: RADIATION PROTECTION IN DIAGNOSTIC X-RAY EQUIPMENT (IEC 60601-1-3:2008)
BS EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments Constancy tests. Imaging performance of computed tomography X-ray equipment
I.S. EN 60601-2-65:2013/A1:2020 Medical electrical equipment - Part 2-65: Particular requirements for the basic safety and essential performance of dental intraoral X-ray equipment (IEC 60601-2-65:2012/A1:2017)
EN ISO 11073-10406:2012 Health informatics - Personal health device communication - Part 10406: Device specialization - Basic electrocardiograph (ECG) (1- to 3-lead ECG) (ISO/IEEE 11073-10406:2012)
04/30124942 DC : DRAFT NOV 2004 BS EN 61223-2-6 - EVALUATION AND ROUTINE TESTING IN MEDICAL IMAGING DEPARTMENTS - PART 2-6: CONSTANCY TESTS - X-RAY EQUIPMENT FOR COMPUTED TOMOGRAPHY
BS EN ISO 11073-10406:2012 Health informatics. Personal health device communication Device specialization. Basic electrocardiograph (ECG) (1- to 3-lead ECG)
UNI EN ISO 11073-10406 : 2013 HEALTH INFORMATICS - PERSONAL HEALTH DEVICE COMMUNICATION - PART 10406: DEVICE SPECIALIZATION - BASIC ELECTROCARDIOGRAPH (ECG) (1- TO 3-LEAD ECG)
CEI EN 60601-2-65 : 2013 MEDICAL ELECTRICAL EQUIPMENT - PART 2-65: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF DENTAL INTRA-ORAL X-RAY EQUIPMENT
CAN/CSA-C22.2 No. 60601-2-65 : 2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-65: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF DENTAL INTRA-ORAL X-RAY EQUIPMENT
EN 61223-2-6:2007 Evaluation and routine testing in medical imaging departments - Part 2-6: Constancy tests - Imaging performance of computed tomography X-ray equipment
EN 61223-3-5:2004 Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment
CAN/CSA C22.2 No. 60601.2.43 : 2011(R2016) MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES
CSA C22.2 No. 60601.1.2 : 2016 MEDICAL ELECTRICAL EQUIPMENT - PART 1-2: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: ELECTROMAGNETIC DISTURBANCES - REQUIREMENTS AND TESTS
CSA C22.2 No. 60601.2.43 : 2011 MEDICAL ELECTRICAL EQUIPMENT - PART 2-43: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF X-RAY EQUIPMENT FOR INTERVENTIONAL PROCEDURES

IEC 60601-2-7:1998 Medical electrical equipment - Part 2-7: Particular requirements for the safety of high-voltage generators of diagnostic X-ray generators
IEC 60336:2005 Medical electrical equipment - X-ray tube assemblies for medical diagnosis - Characteristics of focal spots
IEC 60364-7-710:2002 Electrical installations of buildings - Part 7-710: Requirements for special installations or locations - Medical locations
IEC 60601-1:2005+AMD1:2012 CSV Medical electrical equipment - Part 1: General requirements for basic safety and essential performance
CFR 21(PTS800-1299) : 0 FOOD AND DRUGS - FOOD AND DRUG ADMINISTRATION, CHAPTER 1 DEPARTMENT OF HEALTH AND HUMAN SERVICES - PARTS 800-1299
ISO 12052:2017 Health informatics — Digital imaging and communication in medicine (DICOM) including workflow and data management
IEC 60613:2010 Electrical and loading characteristics of X-ray tube assemblies for medical diagnosis
IEC TR 60513:1994 Fundamental aspects of safety standards for medical electrical equipment
IEC 60601-1-2:2014 Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests
IEC 61223-3-5:2004 Evaluation and routine testing in medical imaging departments - Part 3-5: Acceptance tests - Imaging performance of computed tomography X-ray equipment
IEC 60601-1-3:2008+AMD1:2013 CSV Medical electrical equipment - Part 1-3: General requirements forbasic safety and essential performance - Collateral Standard: Radiation protection in diagnostic X-ray equipment
ISO 497:1973 Guide to the choice of series of preferred numbers and of series containing more rounded values of preferred numbers
ISO 7000:2014 Graphical symbols for use on equipment Registered symbols

Access your standards online with a subscription