IEC 60364-5-56:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-31-2021
English - French
07-30-2009
FOREWORD
560.1 Scope
560.2 Normative references
560.3 Terms and definitions
560.4 Classification
560.5 General
560.6 Electrical sources for safety services
560.7 Circuits of safety services
560.8 Wiring systems
560.9 Emergency escape lighting applications
560.10 Fire protection applications
Annex A (informative) Guidance for emergency lighting
Annex B (informative) Guidance for fire protection
equipment
Annex C (informative) List of notes concerning certain
countries
Bibliography
IEC 60364-5-56:2009 covers general requirements for safety services, selection and erection of electrical supply systems for safety services and electrical safety sources. Standby electrical supply systems are outside the scope of this part. This part does not apply to installations in hazardous areas (BE3), for which requirements are given in IEC 60079-14. This second edition of IEC 60364-5-56 comes about as a result of changes to Clause 556, Safety services, of IEC 60364-5-55 (2001), as modified by its amendment 1 (2001). It replaces Clause 556 of IEC 60364-5-55:2001. Clause 556 is to be withdrawn at the time of publication of this new Part 56. The main changes with regard to the previous edition are listed below:
1) Many more definitions are included, e.g. response time, central power supply system, low power supply system, preferential circuit and escape route.
2) Automatic supplies are now classified according to the maximum changeover times, for example a supply classified as short break means an automatic supply is available within 0,5 s.
3) Safety sources that can operate in parallel are specifically recognized in 560.6.9.
4) Requirements are now given for batteries used for safety sources for central and low power supply sources.
5) Drawings are now required, such as a single-line diagram, drawings showing the location of equipment and a list of equipment permanently connected to the safety power supply.
6) Operating instructions are now required.
7) Detailed requirements are now given for emergency escape lighting applications, direct current circuits and fire protection applications.
8) Additional requirements for initial verification and periodic inspection and testing are now included in the standard.
9) Two annexes are now included (Annex A and Annex B) giving guidance for emergency lighting and guidance for fire protection equipment, respectively.
Committee |
TC 64
|
DevelopmentNote |
Stability Date: 2017. (09/2017)
|
DocumentType |
Standard
|
Pages |
38
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
CEI 64-8/5:2021 | Identical |
HD 60364-5-56:2010/A12:2017 | Identical |
I.S. HD 60364-5-56:2010 | Identical |
DIN VDE 0100-560 : 2013-10 | Identical |
VDE 0100-560 : 2013-10 | Identical |
PN IEC 60364-5-56 : 1999 | Identical |
SAC GB/T 16895.33 : 2017 | Identical |
HD 384.5.56 : 200S1 | Similar to |
BS EN 60598-2-22:2014 | Luminaires Particular requirements. Luminaires for emergency lighting |
ISO 16069:2017 | Graphical symbols — Safety signs — Safety way guidance systems (SWGS) |
EN 60947-6-1:2005/A1:2014 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT (IEC 60947-6-1:2005/A1:2013) |
BS ISO 16069:2017 | Graphical symbols. Safety signs. Safety way guidance systems (SWGS) |
I.S. HD 60364-7-718:2013 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-718: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - COMMUNAL FACILITIES AND WORKPLACES (IEC 60364-7-718:2011 (EQV)) |
EN 60598-2-22:2014/AC:2016-09 | LUMINAIRES - PART 2-22: PARTICULAR REQUIREMENTS - LUMINAIRES FOR EMERGENCY LIGHTING (IEC 60598-2-22:2014/COR2:2016) |
UNE-EN 15869-2:2011 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements |
DIN EN 15869-2:2010-06 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
VDI 6300 Blatt 1:2016-05 | Genetic engineering operations in genetic engineering facilities - Guidance on safe operation of genetic engineering facilities |
VDI 3819 Blatt 2:2013-07 | Fire protection building services - Functions and correlations |
BIS IS/ISO 8528-12 : 1997(R2014) | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN ALTERNATING CURRENT GENERATING SETS - PART 12: EMERGENCY POWER SUPPLY TO SAFETY SERVICES |
BS 7698-12:1998 | Reciprocating internal combustion engine driven alternating current generating sets Emergency power supply to safety devices |
HD 60364-7-718:2013/A12:2017 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-718: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - COMMUNAL FACILITIES AND WORKPLACES |
18/30371712 DC | BS EN 60947-6-1. Low-voltage switchgear and controlgear Part 6-1. Multiple function equipment. Transfer switching equipment |
I.S. EN 60598-2-22:2014 | LUMINAIRES - PART 2-22: PARTICULAR REQUIREMENTS - LUMINAIRES FOR EMERGENCY LIGHTING |
IEC 60364-7-718:2011 | Low-voltage electrical installations - Part 7-718: Requirements for special installations or locations - Communal facilities and workplaces |
ISO 8528-12:1997 | Reciprocating internal combustion engine driven alternating current generating sets — Part 12: Emergency power supply to safety services |
IEC 61991:2000 | Railway applications - Rolling stock - Protective provisions against electrical hazards |
UNI EN 15869-2 : 2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE-PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
I.S. EN 15869-2:2010 | INLAND NAVIGATION VESSELS - ELECTRICAL SHORE CONNECTION, THREE PHASE CURRENT 400 V, UP TO 63 A, 50 HZ - PART 2: ONSHORE UNIT, SAFETY REQUIREMENTS |
I.S. EN 60947-6-1:2005 | LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 6-1: MULTIPLE FUNCTION EQUIPMENT - TRANSFER SWITCHING EQUIPMENT |
GOST R ISO 8528-12 : 2005 | RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN ALTERNATING CURRENT GENERATING SETS - PART 12: EMERGENCY POWER SUPPLY TO SAFETY SERVICES |
IEC 61024-1-2:1998 | Protection of structures against lightning - Part 1-2: General principles - Guide B - Design, installation, maintenance and inspection of lightning protection systems |
BS EN 15869-2:2010 | Inland navigation vessels. Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz Onshore unit, safety requirements |
IEC 60598-2-22:2014+AMD1:2017 CSV | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
IEC 60947-6-1:2005+AMD1:2013 CSV | Low-voltage switchgear and controlgear - Part 6-1: Multiple functionequipment - Transfer switching equipment |
EN 15869-2:2010 | Inland navigation vessels - Electrical shore connection, three phase current 400 V, up to 63 A, 50 Hz - Part 2: Onshore unit, safety requirements |
UNE-EN 60598-2-22:2015 | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
16/30322000 DC : 0 | BS ISO 16069 - GRAPHICAL SYMBOLS - SAFETY SIGNS - SAFETY WAY GUIDANCE SYSTEMS (SWGS) |
11/30249765 DC : 0 | BS EN 60598-2-22 - LUMINAIRES - PART 2-22: PARTICULAR REQUIREMENTS - LUMINAIRES FOR EMERGENCY LIGHTING |
UNE-EN 60947-6-1:2006 | Low-voltage switchgear and controlgear -- Part 6-1: Multiple function equipment - Transfer switching equipment (IEC 60947-6-1:2005) |
S.R. HD 60364-7-718:2013 | LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-718: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - COMMUNAL FACILITIES AND WORKPLACES |
BS EN 60947-6-1:2005 | Low-voltage switchgear and controlgear Multiple function equipment. Transfer switching equipment |
UNE-HD 60364-7-718:2014 | Low-voltage electrical installations - Part 7-718: Requirements for special installations or locations - Communal facilities and workplaces |
IEC 62034:2012 | Automatic test systems for battery powered emergency escape lighting |
IEC 60364-4-43:2008 | Low-voltage electrical installations - Part 4-43: Protection for safety - Protection against overcurrent |
IEC 60702-1:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltage not exceeding 750 V - Part 1: Cables |
IEC 62040-1-1:2002 | Uninterruptible power systems (UPS) - Part 1-1: General and safety requirements for UPS used in operator access areas |
ISO 8528-12:1997 | Reciprocating internal combustion engine driven alternating current generating sets — Part 12: Emergency power supply to safety services |
ISO 30061:2007 | Emergency lighting |
IEC 60332-1-2:2004+AMD1:2015 CSV | Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame |
IEC 62040-1-2:2002 | Uninterruptible power systems (UPS) - Part 1-2: General and safety requirements for UPS used in restricted access locations |
IEC 62040-3:2011 | Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements |
IEC 60079-14:2013 | Explosive atmospheres - Part 14: Electrical installations design, selection and erection |
IEC 60598-2-22:2014+AMD1:2017 CSV | Luminaires - Part 2-22: Particular requirements - Luminaires for emergency lighting |
IEC 62091:2007 | Low-voltage switchgear and controlgear - Controllers for drivers of stationary fire pumps |
AS 60598.2.22:2019 | Luminaires Particular requirements - Luminaires for emergency lighting (IEC 60598-2-22:2017 (ED.4.1) MOD) |
IEC 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
DIN 4102-12:1998-11 | FIRE BEHAVIOUR OF BUILDING MATERIALS AND BUILDING COMPONENTS - PART 12: CIRCUIT INTEGRITY MAINTENANCE OF ELECTRIC CABLE SYSTEMS; REQUIREMENTS AND TESTING |
IEC 60702-2:2002+AMD1:2015 CSV | Mineral insulated cables and their terminations with a rated voltagenot exceeding 750 V - Part 2: Terminations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.