IEC 60354:1991
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Loading guide for oil-immersed power transformers
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
12-15-2005
English - French, English, French
10-15-1991
FOREWORD
Section 1. General
1.1 Scope
1.2 Object
1.3 Definitions
1.4 General limitations and effects of loading
beyond nameplate rating
1.5 Specific limitations for distribution transformers
1.6 Specific limitations for medium power transformers
1.7 Specific limitations for large power transformers
Section 2. Determination of temperatures
2.1 Symbols
2.2 Direct measurement of hot-spot temperature
2.3 Assumed thermal characteristics
2.4 Steady-state temperature equations
2.5 Transient temperature equations
2.6 Thermal ageing of transformer insulation
2.7 Ambient temperature
2.8 Computer program
Section 3. Loading tables
3.1 Limitations applicable to loading tables
3.2 Method of representing an actual load cycle by an
equivalent two-step rectangular load cycle
3.3 Normal continuous loading
3.4 Normal cyclic loading
3.5 Emergency cyclic loading
Annexes
A Equivalent rating for auto-transformers
B Alternative method for determining the winding
oil average temperature rise
C Information to be supplied with enquiry and order
D Calculation of parameters for sinusoidal variation
of ambient temperature
E Example of simplified application of the guide
Provides recommendations for the specification and loading of power transformers complying with IEC 60076, from the point of view of operating temperatures and thermal ageing. Gives recommendations for loading above the name-plate rating and guidance for the planner to choose rated quantities for new installations.
Committee |
TC 14
|
DevelopmentNote |
Also numbered as BS 7735(1994) (10/2005) Also numbered as AS 2374.7. (08/2006)
|
DocumentType |
Standard
|
Pages |
157
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
VDE 0536 : 1977 | Identical |
PN IEC 60354 : 1999 | Identical |
NEN NPR 10354 : 1992 | Identical |
CEI 14-15 : 2006 | Identical |
SAC GB/T 15164 : 1994 | Identical |
UNE 20110:1995 | Identical |
DIN VDE 0536 : 1977 | Identical |
DIN 57536 : 1977 | Identical |
DIN 57536 : 1977 | Corresponds |
BS IEC 60076-8:1997 | Power transformers Application guide |
CEI 14-4/8 : 2001 | POWER TRANSFORMERS - APPLICATION GUIDE |
96/205920 DC : 0 | PREN 50216-10-1 - POWER TRANSFORMERS AND REACTOR FITTINGS - PART 10: COOLING EQUIPMENT - SECTION 1: REMOVABLE RADIATORS FOR OIL-IMMERSED TRANSFORMERS |
CEI EN 61378-2 : 2002 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
11/30253145 DC : 0 | BS EN 62271-202 ED2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 202: HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATION |
EN 60214:1997 | On-load tap-changers |
02/205931 DC : DRAFT MAY 2002 | IEC 60214-2. ED.1 - TAP CHANGERS - PART 2: APPLICATION GUIDE |
03/100561 DC : DRAFT JULY 2003 | IEC 60422 ED.3 - SUPERVISION AND MAINTENANCE GUIDE FOR MINERAL INSULATING OILS IN ELECTRICAL EQUIPMENT |
98/232755 DC : DRAFT DEC 1998 | IEC 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES |
CEI 14-41 : 2011 | TAP-CHANGERS - PART 2: APPLICATION GUIDE |
IEC 60076-7:2018 | Power transformers - Part 7: Loading guide for mineral-oil-immersed power transformers |
NF EN 50329 : 2005 AMD 1 2011 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - TRACTION TRANSFORMERS |
BS 4571:1994 | On-load tap-changers |
VDE 0532-42 : 2001 | CONVERTOR TRANSFORMERS - PART 2: TRANSFORMERS FOR HVDC APPLICATIONS |
BS 4571:1978 | Specification for on-load tap-changers |
BS EN 60214:1998 | On-load tap-changers |
BS 171-1:1978 | Power transformers General |
04/30111589 DC : 0 | |
10/30215366 DC : 0 | BS EN 60422 - MINERAL INSULATING OILS IN ELECTRICAL EQUIPMENT - SUPERVISION AND MAINTENANCE GUIDANCE |
IEC 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
BS 223:1985 | Specification for bushings for alternating voltages above 1000 V |
I.S. HD 428.1:1992 | THREE PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS, 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 24 KV |
02/207269 DC : 0 | IEC 60422 ED.3 - SUPERVISION AND MAINTENANCE GUIDE FOR MINERAL INSULATING OILS IN ELECTRICAL EQUIPMENT |
BS QC 790101:1992 | Harmonized system of quality assessment for electronic components. Semiconductor devices. Integrated circuits. Sectional specification for semiconductor integrated circuits excluding hybrid circuits. Internal visual examination for semiconductor integrated circuits excluding hybrid circuits |
IEEE C57.91-2011 REDLINE | IEEE Guide for Loading Mineral-Oil-Immersed Transformers and Step-Voltage Regulators |
IEC 60214-2:2004 | Tap-changers - Part 2: Application guide |
IEC 60076-8:1997 | Power transformers - Part 8: Application guide |
IEC 61330:1995 | High-voltage/low voltage prefabricated substations |
UNE-EN 50329:2004 | Railway applications - Fixed installations - Traction transformers |
BS EN 61378-2:2001 | Convertor transformers Transformers for HVDC applications |
IEEE C57.119-2001 | IEEE Recommended Practice for Performing Temperature Rise Tests on Oil-Immersed Power Transformers at Loads Beyond Nameplate Ratings |
04/30117440 DC : DRAFT JUL 2004 | IEC 60076-13. ED.1 - POWER TRANSFORMERS - PART 13: SELF-PROTECTED LIQUID FILLED TRANSFORMERS |
02/714212 DC : DRAFT DEC 2002 | IEC 62271-202 ED.1 - HIGH VOLTAGE/LOW VOLTAGE PREFABRICATED SUBSTATIONS |
HD 428.1 S1:1992/AC:2011 | THREE PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS, 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 24 KV |
EN 61378-2:2001 | Convertor transformers - Part 2: Transformers for HVDC applications |
EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.