IEC 60335-2-92:2002
Current
The latest, up-to-date edition.
Household and similar electrical appliances - Safety - Part 2-92: Particular requirements for pedestrian-controlled mains-operated lawn scarifiers and aerators
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
07-26-2002
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 General requirement
5 General conditions for the tests
6 Classification
7 Marking and instructions
8 Protection against access to live parts
9 Starting a motor-operated appliance
10 Power input and current
11 Heating
12 Void
13 Leakage current and electric strength at operating
temperature
14 Transient overvoltages
15 Moisture resistance
16 Leakage current and electric strength
17 Overload protection of transformers and associated circuits
18 Endurance
19 Abnormal operation
20 Stability and mechanical hazards
21 Mechanical strength
22 Construction
23 Internal wiring
24 Components
25 Supply connection and external flexible cords
26 Terminals for external conductors
27 Provision for earthing
28 Screws and connections
29 Clearances, creepage distances and solid insulation
30 Resistance to heat and fire
31 Resistance to rusting
32 Radiation, toxicity and similar hazards
Annexes
Annex AA (normative) Test enclosure construction
Annex BB (normative) Base for thrown object test enclosure
Annex CC (normative) Target panel elevation zones and
recommended test report for thrown object test
Bibliography
Figures
Table
Deals with the safety of pedestrian-controlled mains-operated electric lawn scarifiers and aerators. These scarifiers have rotating cutters for regenerating lawns by, for instance, combing out grass thatch and moss, or by cutting vertically into the lawn face. These scarifiers are designed primarily for home use, with a rated voltage not more than 250 V single phase. For lawnmowers, see IEC 60335-2-77; for lawn trimmers, see IEC 60335-2-91. The contents of the corrigendum of May 2003 have been included in this copy.
Committee |
TC 116
|
DevelopmentNote |
To be used in conjunction with IEC 60335-1. (07/2002) Stability Date: 2018. (09/2017)
|
DocumentType |
Standard
|
Pages |
44
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
GOST IEC 60335-2-92 : 2004 | Identical |
NBN EN 60335-2-92 : 2006 | Identical |
NF EN 60335 2-92 : 2005 | Identical |
NEN EN IEC 60335-2-92 : 2005 | Identical |
I.S. EN 60335-2-92:2005 | Identical |
AS/NZS 60335.2.92:2003 | Identical |
SN EN 60335-2-92 : 2005 | Identical |
CEI EN 60335-2-92 : 2005 | Identical |
EN 60335-2-92:2005 | Identical |
DIN EN 60335-2-92 : 2006 | Identical |
NEN IEC 60335-2-92 : 2000 | Identical |
10/30214886 DC : 0 | BS EN ISO 5395-2 - GARDEN EQUIPMENT - SAFETY OF POWERED LAWNMOWERS - PART 2: PEDESTRIAN CONTROLLED LAWNMOWERS |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
IEC 60252:1993 | A.C. motor capacitors |
IEC 60320-1:2015 | Appliance couplers for household and similar general purposes - Part 1: General requirements |
IEC 60238:2016+AMD1:2017 CSV | Edison screw lampholders |
IEC 60738-1:2006+AMD1:2009 CSV | Thermistors - Directly heated positive temperature coefficient -Part 1: Generic specification |
IEC 60335-2-91:2008 | Household and similar electrical appliances - Safety - Part 2-91: Particular requirements for walk-behind and hand-held lawn trimmers and lawn edge trimmers |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60950:1999 | Safety of information technology equipment |
ISO 3411:2007 | Earth-moving machinery Physical dimensions of operators and minimum operator space envelope |
ISO 3767-3:2016 | Tractors, machinery for agriculture and forestry, powered lawn and garden equipment Symbols for operator controls and other displays Part 3: Symbols for powered lawn and garden equipment |
CISPR 14-2:2015 RLV | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
ISO 13852:1996 | Safety of machinery Safety distances to prevent danger zones being reached by the upper limbs |
IEC 60320-2-3:1998+AMD1:2004 CSV | Appliance couplers for household and similar general purposes - Part 2-3: Appliance couplers with a degree of protection higher than IPX0 |
ISO 1463:2003 | Metallic and oxide coatings Measurement of coating thickness Microscopical method |
ISO 2758:2014 | Paper Determination of bursting strength |
IEC 60695-2-11:2014 | Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) |
IEC 61558-2-6:2009 | Safety of transformers, reactors, power supply units and similar products for supply voltages up to 1 100 V - Part 2-6: Particular requirements and tests for safety isolating transformers and power supply units incorporating safety isolating transformers |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
IEC 60999-1:1999 | Connecting devices - Electrical copper conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm2 up to 35 mm2 (included) |
IEC 60249-2-4:1987 | Base materials for printed circuits. Part 2: Specifications. Specification No. 4: Epoxide woven glass fabric copper-clad laminated sheet, general purpose grade |
IEC 60249-2-5:1987 | Base materials for printed circuits. Part 2: Specifications. Specification No. 5: Epoxide woven glass fabric copper-clad laminated sheet of defined flammability (vertical burning test) |
IEC 60051-2:1984 | Direct acting indicating analogue electrical measuring instruments and their accessories. Part 2: Special requirements for ammeters and voltmeters |
IEC 61180-2:1994 | High-voltage test techniques for low-voltage equipment - Part 2: Test equipment |
IEC 61558-1:2017 | Safety of transformers, reactors, power supply units and combinations thereof - Part 1: General requirements and tests |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC 61643-1:2005 | Low-voltage surge protective devices - Part 1: Surge protective devices connected to low-voltage power distribution systems - Requirements and tests |
ISO 3767-1:2016 | Tractors, machinery for agriculture and forestry, powered lawn and garden equipment Symbols for operator controls and other displays Part 1: Common symbols |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
ISO 9772:2012 | Cellular plastics Determination of horizontal burning characteristics of small specimens subjected to a small flame |
IEC 61058-1:2016 | Switches for appliances - Part 1: General requirements |
IEC 60335-2-77:2002 | Household and similar electrical appliances - Safety - Part 2-77: Particular requirements for pedestrian controlled mains-operated lawnmowers |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC 60598-1:2014+AMD1:2017 CSV | Luminaires - Part 1: General requirements and tests |
IEC 60061-1:2005 CSV | Lamp caps and holders together with gauges for the control of interchangeability and safety - Part 1: Lamp caps |
IEC 60906-1:2009 | IEC system of plugs and socket-outlets for household and similar purposes - Part 1: Plugs and socket-outlets 16 A 250 V a.c. |
IEC 61000-3-3:2013 RLV | Electromagnetic compatibility (EMC) - Part 3-3: Limits - Limitation of voltage changes, voltage fluctuations and flicker in public low-voltage supply systems, for equipment with rated current ≤ 16 A per phase and not subject to conditional connection |
ISO 2178:2016 | Non-magnetic coatings on magnetic substrates Measurement of coating thickness Magnetic method |
IEC 60335-2-29:2016 | Household and similar electrical appliances - Safety - Part 2-29: Particular requirements for battery chargers |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
ISO 7000:2014 | Graphical symbols for use on equipment Registered symbols |
IEC 61032:1997 | Protection of persons and equipment by enclosures - Probes for verification |
ISO 3864:1984 | Safety colours and safety signs |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 60998-2-1:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-1: Particular requirements for connecting devices as separate entities with screw-type clamping units |
IEC 60990:2016 | Methods of measurement of touch current and protective conductor current |
IEC 60730-1:2013+AMD1:2015 CSV | Automatic electrical controls - Part 1: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.