IEC 60331-3:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Tests for electric cables under fire conditions - Circuit integrity - Part 3: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV tested in a metal enclosure
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
09-12-2022
English - French
05-19-2009
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test environment
5 Test apparatus
6 Test specimen (electric power and control cables with
rated voltage up to and including 600 V/1000 V)
7 Test procedure (electric power and control cables
with rated voltage up to and including 600 V/1000 V)
8 Performance requirements (electric power and control
cables with rated voltage up to and including 600 V/1000 V)
9 Retest procedure
10 Test report (electric power and control cables with rated
voltage up to and including 600 V/1000 V)
Annex A (normative) - Verification procedure for the
source of heat
Annex B (informative) - Guidance on the choice of recommended
test apparatus (burner And venturi)
Bibliography
IEC 60331-3:2009 specifies the test apparatus and procedure and gives the performance requirements, including recommended flame application times, for low-voltage power cables of rated voltage up to and including 0,6/1,0 kV, and control cables with a rated voltage which are required to maintain circuit integrity when tested in a metal enclosure and when subject to fire and mechanical shock under specified conditions. This standard describes the means of sample preparation, the continuity checking arrangements, the electrical testing procedure, the method of burning the cables and the method of shock production and gives requirements for evaluating test results. NOTE All cables assessed by this method should first have been assessed against the test of IEC 60331-1 or IEC 60331-2. Such performance may be recognized by the marking according to Clause 11 of IEC 60331-1 or Clause 11 of IEC 60331-2. Annex A provides the method of verification of the burner and control system used for the test. It has the status of a horizontal standard in accordance with IEC Guide 104.
Committee |
TC 20
|
DevelopmentNote |
Stability Date: 2023. (04/2018)
|
DocumentType |
Standard
|
Pages |
49
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
AS/NZS IEC 60331.3:2017 | Identical |
GOST IEC 60331-3 : 2013 | Identical |
BS EN 50553 : 2012 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
BS 7671(2008) : 2018 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
BS 5266-1:2016 | Emergency lighting Code of practice for the emergency lighting of premises |
11/30227604 DC : 0 | BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY ESCAPE LIGHTING OF PREMISES |
I.S. EN 50553:2012 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
15/30325295 DC : 0 | BS 8592 - ELECTRIC CABLES - THERMOSETTING INSULATED, NON-ARMOURED, FIRE-RESISTANT, SINGLE CORE NON-SHEATHED CABLES OF RATED VOLTAGE 450/750 V, HAVING LOW EMISSION OF SMOKE AND CORROSIVE GASES WHEN AFFECTED BY FIRE - SPECIFICATION |
BS 5266-1:2011 | Emergency lighting Code of practice for the emergency escape lighting of premises |
NF EN 50553 : 2012 AMD 1 2017 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
BS 8592:2016 | Electric cables. Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire. Specification |
16/30331553 DC : 0 | BS 5266-1 - EMERGENCY LIGHTING - PART 1: CODE OF PRACTICE FOR THE EMERGENCY LIGHTING OF PREMISES |
C22.2 NO. 245-17 | Marine shipboard cable |
EN 50553 : 2012 AMD 1 2016 | RAILWAY APPLICATIONS - REQUIREMENTS FOR RUNNING CAPABILITY IN CASE OF FIRE ON BOARD OF ROLLING STOCK |
BS 7671(2008) : 2008 | REQUIREMENTS FOR ELECTRICAL INSTALLATIONS - IET WIRING REGULATIONS |
IEC 60331-2:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 2: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter not exceeding 20 mm |
IEC 60269-3:2010+AMD1:2013 CSV | Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F |
IEC 60331-1:2009 | Tests for electric cables under fire conditions - Circuit integrity - Part 1: Test method for fire with shock at a temperature of at least 830 °C for cables of rated voltage up to and including 0,6/1,0 kV and with an overall diameter exceeding 20 mm |
IEC 60584-1:2013 | Thermocouples - Part 1: EMF specifications and tolerances |
IEC 61034-1:2005+AMD1:2013 CSV | Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.