IEC 60317-30:1990
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Specifications for particular types of winding wires. Part 30: Polyimide enamelled rectangular copper wire, class 220
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-19-2009
10-15-1990
FOREWORD
INTRODUCTION
Clause
1 Scope
2 Normative references
3 Definitions and general notes on methods of test and
appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
22 High temperature failure
23 Pin hole test
30 Packaging
Specifies the requirements of enamelled rectangular copper winding wire of class 220 with a sole coating based on polymide resin. Coverage includes dimensions, elongation, springiness, heat shock, temperature index, solderability, breakdown voltage and loss of mass.
DevelopmentNote |
Also numbered as BS EN 60317-30. (10/2005)
|
DocumentType |
Standard
|
Pages |
21
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Standards | Relationship |
NFC 31 680 : 1990 | Similar to |
HD 555.30 : 200S1 | Similar to |
NF EN 60317-30 : 1998 AMD 2 2006 | Identical |
NEN EN IEC 60317-30 : 1997 AMD 2 2006 | Identical |
NEN 10317-30 : 1997 | Identical |
I.S. EN 60317-30:1998 | Identical |
PN EN 60317-30 : 2002 AMD 2 2006 | Identical |
SN EN 60317-30 : 1996 AMD 2 2005 | Identical |
UNE-EN 60317-30:1996 | Identical |
CEI 55-2/30 : 4ED 1993 | Identical |
EN 60317-30:1996/A2:2005 | Identical |
UNE 21179-30:1993 | Identical |
BS 6811-4.7(1993) : 1993 AMD 9464 | Similar to |
BS IEC 61858-2 : 2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
BS EN 61858-2:2014 | Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS |
I.S. EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
EN 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
12/30273912 DC : 0 | BS EN 61858-2 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED EIS - PART-2: FORM-WOUND EIS |
10/30206053 DC : 0 | BS EN 60317-61 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 61: POLYESTER GLASS FIBRE WOUND, IMPREGNATED OR NOT IMPREGNATED, BARE, GRADE 1 OR GRADE 2 ENAMELLED RECTANGULAR COPPER WINDING WIRE WITH TEMPERATURE INDEX 180 |
I.S. EN 61858-2:2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
BIS IS 13730-31 : 1997 AMD 1 2013 | SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 31: GLASS-FIBRE WOUND RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED RECTANGULAR COPPER WIRE, TEMPERATURE INDEX 180 |
NF EN 61858 : 2009 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
BS EN 61858:2008 | Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS |
IEC 60034-18-22:2000 | Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions |
10/30206059 DC : 0 | BS EN 60317-62 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 62: POLYESTER GLASS FIBRE WOUND, IMPREGNATED OR NOT IMPREGNATED, BARE, GRADE 1 OR GRADE 2 ENAMELLED RECTANGULAR COPPER WINDING WIRE WITH TEMPERATURE INDEX 200 |
11/30257662 DC : 0 | BS EN 60317-0-2 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-2: GENERAL REQUIREMENTS - ENAMELLED RECTANGULAR COPPER WIRE |
IEC 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
IEC 61858:2008 | Electrical insulation systems - Thermal evaluation of modifications to an established wire-wound EIS |
EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
IEC 60317-0-2:2013 | Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.