IEC 60317-16:1990
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Specifications for particular types of winding wires. Part 16: Polyester enamelled rectangular copper wire, class 155
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
01-09-2012
10-15-1990
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions and general notes on methods of test
and appearance
4 Dimensions
5 Electrical resistance
6 Elongation
7 Springiness
8 Flexibility and adherence
9 Heat shock
10 Cut-through
11 Resistance to abrasion
12 Resistance to solvents
13 Breakdown voltage
14 Continuity of insulation
15 Temperature index
16 Resistance to refrigerants
17 Solderability
18 Heat or solvent bonding
19 Dielectric dissipation factor
20 Resistance to transformer oil
21 Loss of mass
22 High temperature failure
23 Pin hole test
30 Packaging
Annex ZA (normative) Other international publications
quoted in this standard with the references
of the relevant European publications
National annex NA (informative) Cross-reference
Describes the requirements of enamelled rectangular copper winding wires of class 155 with a sole coating based on polyester resin, which may be modified providing it retains the chemical identity of the original resin and meets all specified wire requirements.
Committee |
TC 55
|
DevelopmentNote |
Also numbered as BS EN 60317-16. (10/2005)
|
DocumentType |
Standard
|
Pages |
21
|
PublisherName |
International Electrotechnical Committee
|
Status |
Withdrawn
|
Supersedes |
Standards | Relationship |
HD 555.16 : 200S2 | Similar to |
NF EN 60317-16 : 95 AMD 1 2001 | Similar to |
NEN EN IEC 60317-16 : 1995 AMD 1 1998 | Identical |
NEN 10317-16 : 1995 | Similar to |
I.S. EN 60317-16:1996 | Identical |
SN EN 60317-16 : 1994 | Identical |
BIS IS 13730-16 : 1996(R2016) | Identical |
CEI 55-2/16 : 4ED 1991 | Identical |
CEI EN 60317-16 : 6ED 2000 | Identical |
EN 60317-16 : 1994 AMD 1 1998 | Identical |
DIN EN 60317-16:1995-11 | Identical |
UNE-EN 60317-16:1995 | Identical |
UNE 21179-16:1993 | Identical |
BIS IS 13730-32 : 1997 AMD 1 2013 | SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 32: GLASS-FIBRE WOUND RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED RECTANGULAR COPPER WIRE, TEMPERATURE INDEX 155 |
BS EN 61858-2:2014 | Electrical insulation systems. Thermal evaluation of modifications to an established electrical insulation system (EIS) Form-wound EIS |
I.S. EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
EN 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
12/30273912 DC : 0 | BS EN 61858-2 - ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED EIS - PART-2: FORM-WOUND EIS |
10/30206053 DC : 0 | BS EN 60317-61 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 61: POLYESTER GLASS FIBRE WOUND, IMPREGNATED OR NOT IMPREGNATED, BARE, GRADE 1 OR GRADE 2 ENAMELLED RECTANGULAR COPPER WINDING WIRE WITH TEMPERATURE INDEX 180 |
BIS IS 13730-31 : 1997 AMD 1 2013 | SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 31: GLASS-FIBRE WOUND RESIN OR VARNISH IMPREGNATED, BARE OR ENAMELLED RECTANGULAR COPPER WIRE, TEMPERATURE INDEX 180 |
NF EN 61858 : 2009 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
BS EN 61858:2008 | Electrical insulation systems. Thermal evaluation of modifications to an established wire-wound EIS |
I.S. EN 61858-2:2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
IEC 60034-18-22:2000 | Rotating electrical machines - Part 18-22: Functional evaluation of insulation systems - Test procedures for wire-wound windings - Classification of changes and insulation component substitutions |
BS IEC 61858-2 : 2014 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED ELECTRICAL INSULATION SYSTEM (EIS) - PART 2: FORM-WOUND EIS |
11/30257662 DC : 0 | BS EN 60317-0-2 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 0-2: GENERAL REQUIREMENTS - ENAMELLED RECTANGULAR COPPER WIRE |
IEC 61858-2:2014 | Electrical insulation systems - Thermal evaluation of modifications to an established electrical insulation system (EIS) - Part 2: Form-wound EIS |
10/30206048 DC : 0 | BS EN 60317-60 - SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 60: POLYESTER GLASS FIBRE WOUND, IMPREGNATED OR NOT IMPREGNATED, BARE, GRADE 1 OR GRADE 2 ENAMELLED RECTANGULAR COPPER WINDING WIRE WITH TEMPERATURE INDEX 155 |
IEC 61858:2008 | Electrical insulation systems - Thermal evaluation of modifications to an established wire-wound EIS |
EN 61858:2008 | ELECTRICAL INSULATION SYSTEMS - THERMAL EVALUATION OF MODIFICATIONS TO AN ESTABLISHED WIRE-WOUND EIS |
IEC 60317-0-2:2013 | Specifications for particular types of winding wires - Part 0-2: General requirements - Enamelled rectangular copper wire |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.