IEC 60104:1987
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
Aluminium-magnesium-silicon alloy wire for overhead line conductors
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
03-04-2022
English - French
12-30-1987
FOREWORD
PREFACE
1 Scope
2 Values for aluminium-magnesium-silicon alloy wire
3 Material
4 Freedom from defects
5 Diameter and tolerance on diameter
6 Length and tolerance on length
7 Joints
8 Sampling
9 Place of testing
10 Mechanical tests
11 Resistivity tests
12 Certificate of compliance
Is applicable to aluminium-magnesium-silicon alloy wires of two types having different mechanical and electrical properties for the manufacture of stranded conductors for overhead power transmission purposes. It specifies the mechanical and electrical properties of wires in the diameter range 1.50 mm to 4.50 mm.
Committee |
TC 7
|
DevelopmentNote |
Stability date: 2017. (07/2015)
|
DocumentType |
Standard
|
Pages |
12
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
Supersedes |
Standards | Relationship |
CAN/CSA-C60104:03 (R2020) | Identical |
DIN 48200-990:1994-03 (Draft) | Identical |
NFC 34 112 : 1992 | Similar to |
UNE 21042:1993 | Identical |
DIN 48200-990:1994-03 (Draft) | Corresponds |
97/202499 DC : 0 | |
02/205756 DC : DRAFT MAY 2002 | IEC 60794-4. ED 2.0 - OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES |
BS EN 62420:2008 | Concentric lay stranded overhead electrical conductors containing one or more gap(s) |
BS EN 60794-4-10:2014 | Optical fibre cables Family specification. Optical ground wires (OPGW) along electrical power lines |
CEI EN 62420 : 2009 | CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S) |
EN 60794-4:2003 | Optical fibre cables - Part 4: Sectional specification - Aerial optical cables along electrical power lines |
CEI EN 62219 : 2002 | OVERHEAD ELECTRICAL CONDUCTORS - FORMED WIRE, CONCENTRIC LAY, STRANDED CONDUCTORS |
BS EN 62219:2002 | Overhead electrical conductors. Formed wire, concentric lay, stranded conductors |
I.S. EN 62420:2008 | CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S) |
IEC 60794-4:2003 | Optical fibre cables - Part 4: Sectional specification - Aerial optical cables along electrical power lines |
06/30156083 DC : DRAFT SEP 2006 | BS EN 62420 - CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR GAP(S) |
I.S. EN 60794-4-10:2014 | OPTICAL FIBRE CABLES - PART 4-10: FAMILY SPECIFICATION - OPTICAL GROUND WIRES (OPGW) ALONG ELECTRICAL POWER LINES |
I.S. EN 60794-4:2003 | OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES |
NF EN 62420 : 2011 | CONCENTRIC LAY STRANDED OVERHEAD ELECTRICAL CONDUCTORS CONTAINING ONE OR MORE GAP(S) |
05/30131909 DC : DRAFT APR 2005 | |
IEC 60794-4-10:2014 | Optical fibre cables - Part 4-10: Family specification - Optical ground wires (OPGW) along electrical power lines |
IEC 62420:2008 | Concentric lay stranded overhead electrical conductors containing one or more gap(s) |
EN 60794-4-10:2014 | Optical fibre cables - Part 4-10: Family specification - Optical ground wires (OPGW) along electrical power lines |
15/30320892 DC : 0 | BS EN 60794-4 - OPTICAL FIBRE CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES |
I.S. EN 62004:2009 | THERMAL RESISTANT ALUMINIUM ALLOY WIRE FOR OVERHEAD LINE CONDUCTOR |
13/30292534 DC : 0 | BS EN 60794-4-10 ED 2.0 - OPTICAL FIBRE CABLES - PART 4-10: FAMILY SPECIFICATION - OPGW (OPTICAL GROUND WIRES) ALONG ELECTRICAL POWER LINES |
I.S. EN 62219:2002 | OVERHEAD ELECTRICAL CONDUCTORS - FORMED WIRE, CONCENTRIC LAY, STRANDED CONDUCTORS |
BS EN 60794-4:2003 | Optical fibre cables Sectional specification. Aerial optical cables along electrical power lines |
NF EN 60794-4 : 2004 | OPTICAL FIBER CABLES - PART 4: SECTIONAL SPECIFICATION - AERIAL OPTICAL CABLES ALONG ELECTRICAL POWER LINES |
IEC 62004:2007 | Thermal-resistant aluminium alloy wire for overhead line conductor |
IEC 62219:2002 | Overhead electrical conductors - Formed wire, concentric lay, stranded conductors |
EN 62004:2009 | Thermal-resistant aluminium alloy wire for overhead line conductor |
EN 62219:2002 | Overhead electrical conductors - Formed wire, concentric lay, stranded conductors |
EN 62420:2008 | Concentric lay stranded overhead electrical conductors containing one or more gap(s) |
IEC 60468:1974 | Method of measurement of resistivity of metallic materials |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.