IEC 60068-2-64:2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
10-11-2019
Spanish, Castilian
04-29-2008
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements for test apparatus
4.1 General
4.2 Basic motion
4.3 Cross-axis motion
4.4 Mounting
4.5 Measuring systems
4.6 Vibration tolerances
4.7 Control strategy
4.8 Vibration response investigation
5 Severities
5.1 Test frequency range
5.2 RMS value of acceleration
5.3 Shape of acceleration spectral density curve
5.4 Test duration
6 Preconditioning
7 Initial measurements and functional performance test
8 Testing
8.1 General
8.2 Initial vibration response investigation
8.3 Low-level excitation for equalization prior to
testing
8.4 Random testing
8.5 Final vibration response investigation
9 Recovery
10 Final measurements and functional performance
11 Information to be given in the relevant specification
12 Information to be given in the test report
Annex A (informative) Standardized test spectra
Annex B (informative) Guidance
Bibliography
IEC 60068-2-64:2008 demonstrates the adequacy of specimens to resist dynamic loads without unacceptable degradation of its functional and/or structural integrity when subjected to the specified random vibration test requirements. Broadband random vibration may be used to identify accumulated stress effects and the resulting mechanical weakness and degradation in the specified performance. This information, in conjunction with the relevant specification, may be used to assess the acceptability of specimens. This standard is applicable to specimens which may be subjected to vibration of a stochastic nature resulting from transportation or operational environments, for example in aircraft, space vehicles and land vehicles. It is primarily intended for unpackaged specimens, and for items in their transportation container when the latter may be considered as part of the specimen itself. However, if the item is packaged, then the item itself is referred to as a product and the item and its packaging together are referred to as a test specimen. This standard may be used in conjunction with IEC 60068-2-47:2005, for testing packaged products. If the specimens are subjected to vibration of a combination of random and deterministic nature resulting from transportation or real life environments, for example in aircraft, space vehicles and for items in their transportation container, testing with pure random may not be sufficient. See IEC 60068-3-8:2003 for estimating the dynamic vibration environment of the specimen and based on that, selecting the appropriate test method. The major changes with regard to the previous edition concern the removal of Method 1 and Method 2, replaced by a single method, and replacement of Annex A with suggested test spectra and removal of Annex C. Also included in this revision is the testing of soft packed specimens.
Committee |
TC 104
|
DevelopmentNote |
Supersedes IEC 60068-2-34, IEC 60068-2-35, IEC 60068-2-36 and IEC 60068-2-37. (03/2001) Stability Date: 2018. (10/2012) NEW CHILD IS ADDED
|
DocumentType |
Standard
|
Pages |
92
|
ProductNote |
NEW CHILD IS ADDED
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
Standards | Relationship |
NBN EN 60068 2-64 : 2010 | Identical |
NEN EN IEC 60068-2-64 : 2008 | Identical |
PN EN 60068-2-64 : 2008 | Identical |
VDE 0468-2-64 : 2009 | Identical |
UNE-EN 60068-2-64:2009 | Identical |
BS EN 60068-2-64:1995 | Identical |
CEI EN 60068-2-64 : 2012 | Identical |
EN 60068-2-64:2008 | Identical |
JIS C 60068-2-64:2023 | Identical |
JIS C 0036:1997 | Identical |
BS EN 60068-2-64:2008 | Identical |
NF EN 60068 2-64 : 2008 | Identical |
DIN EN 60068-2-64 : 1995 | Identical |
NEN 10068-2-64 : 1994 | Identical |
ONORM OVE EN 60068-2-64 : 1996 | Identical |
I.S. EN 60068-2-64:2008 | Identical |
SN EN 60068-2-64 : 1994 | Identical |
15/30272172 DC : 0 | BS EN ISO 13355 - PACKAGING - COMPLETE, FILLED TRANSPORT PACKAGES AND UNIT LOADS - VERTICAL RANDOM VIBRATION TEST |
UNE-EN 50556:2011 | Road traffic signal systems |
CEI EN 60601-1-11 : 2016 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT |
12/30266709 DC : 0 | BS EN ISO 4064-2 - WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS |
BS ISO 12405-1:2011 | Electrically propelled road vehicles. Test specification for lithium-ion traction battery packs and systems High-power applications |
CEI EN 60068-2-47 : 2006 | ENVIRONMENTAL TESTING - PART 2-47: TESTS - MOUNTING OF SPECIMENS FOR VIBRATION, IMPACT AND SIMILAR DYNAMIC TESTS |
09/30180346 DC : 0 | BS ISO 12405-1 - ELECTRICALLY PROPELLED ROAD VEHICLES - TEST SPECIFICATION FOR LITHIUM-ION TRACTION BATTERY SYSTEMS - PART 1: HIGH POWER APPLICATIONS |
OIML R 139-1 : 2014 | COMPRESSED GASEOUS FUEL MEASURING SYSTEMS FOR VEHICLES - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
DIN ISO 10109-12 E : 2005 | OPTICS AND OPTICAL INSTRUMENTS - ENVIRONMENTAL REQUIREMENTS - PART 12: CONDITIONS OF TRANSPORT FOR OPTICAL INSTRUMENTS |
UNE-EN 61373:2011 | Railway applications - Rolling stock equipment - Shock and vibration tests |
16/30309512 DC : 0 | BS EN 62327 ED 2.0 - RADIATION PROTECTION INSTRUMENTATION - HAND-HELD INSTRUMENTS FOR THE DETECTION AND IDENTIFICATION OF RADIONUCLIDES AND FOR THE ESTIMATION OF AMBIENT DOSE EQUIVALENT RATE FROM PHOTON RADIATION |
14/30266573 DC : 0 | BS EN 12368 - TRAFFIC CONTROL EQUIPMENT - SIGNAL HEADS |
14/30295302 DC : 0 | BS EN 61587-1 ED. 4.0 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITIONS |
DIN EN 16882 E : 2017 | ROAD VEHICLES - SECURITY OF THE MECHANICAL SEALS USED ON TACHOGRAPHS - REQUIREMENTS AND TEST PROCEDURES |
I.S. EN 61373:2010 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS |
12/30258507 DC : 0 | BS EN 62575-1 - RADIO FREQUENCY (RF) BUK ACOUSTIC WAVE (BAW) FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
ANSI/AAMI CI86:2017 | COCHLEAR IMPLANT SYSTEMS: REQUIREMENTS FOR SAFETY, FUNCTIONAL VERIFICATION, LABELING AND RELIABILITY REPORTING |
PREN ISO 80601-2-61 : DRAFT 2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE |
UNI EN ISO 80601-2-61 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT |
CEI EN 60068-2-57 : 2014 | ENVIRONMENTAL TESTING - PART 2-57: TESTS - TEST FF: VIBRATION - TIME HISTORY AND SINE-BEAT METHOD |
BS EN 62575-1:2016 | Radio frequency (RF) bulk acoustic wave (BAW) filters of assessed quality Generic specification |
EN 50556:2011 | Road traffic signal systems |
09/30203808 DC : 0 | BS EN ISO 80601-2-12 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
PD CEN ISO/TS 14907-1:2015 | Electronic fee collection. Test procedures for user and fixed equipment Description of test procedures |
12/30268049 DC : 0 | BS EN 62689-1 - CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
DIN ISO 9022-22:2012-10 | Optics and photonics - Environmental test methods - Part 22: Combined cold, dry heat or temperature change with bump or random vibration (ISO 9022-22:2012) |
15/30325282 DC : 0 | BS EN 62884-1 - MEASUREMENT TECHNIQUES OF PIEZOELECTRIC, DIELETIRIC AND ELECTROSTATIC OSCILLATORS - PART 1: BASIC METHODS FOR THE MEASUREMENT |
PREN 12368 : DRAFT 2014 | TRAFFIC CONTROL EQUIPMENT - SIGNAL HEADS |
10/30240248 DC : 0 | BS EN 60862-1 - SURFACE ACOUSTIC WAVE (SAW) FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
04/30112662 DC : DRAFT APR 2004 | IEC 61810-7 ED.2 - ELECTROMECHANICAL ELEMENTARY RELAYS - PART 7: TEST AND MEASUREMENT PROCEDURES |
BS EN 60601-1-12:2015 | Medical electrical equipment General requirements for basic safety and essential performance. Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment |
08/30190664 DC : 0 | BS ISO 7752-1 - LIFTING APPLIANCES - CONTROLS - LAYOUT AND CHARACTERISTICS - PART 1: GENERAL PRINCIPLES |
BS EN 62884-1:2017 | Measurement techniques of piezoelectric, dielectric and electrostatic oscillators Basic methods for the measurement |
BS ISO 17089-1:2010 | Measurement of fluid flow in closed conduits. Ultrasonic meters for gas Meters for custody transfer and allocation measurement |
BS EN 60068-2-47:2005 | Environmental testing Tests. Mounting of specimens for vibration, impact and similar dynamic tests |
BS EN 12966:2014 | Road vertical signs. Variable message traffic signs |
OIML R 46-1 & 2 : 2012 | ACTIVE ELECTRICAL ENERGY METERS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS; PART 2: METROLOGICAL CONTROLS AND PERFORMANCE TESTS |
DD CEN ISO/TS 14907-1:2010 | Electronic fee collection. Test procedures for user and fixed equipment Description of test procedures |
BS EN 60068-2-57:2013 | Environmental testing Tests. Test Ff: Vibration. Time-history and sine-beat method |
CSA Z18778 : 2008 : R2018 | RESPIRATORY EQUIPMENT - INFANT MONITORS - PARTICULAR REQUIREMENTS |
CEI EN 61753-101-3 : 2010 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS PERFORMANCE STANDARD - PART 101-3: FIBRE MANAGEMENT SYSTEMS FOR CATEGORY U - UNCONTROLLED ENVIRONMENT |
OIML R 143 : 2009 | INSTRUMENTS FOR THE CONTINUOUS MEASUREMENT OF SO[2] IN STATIONARY SOURCE EMISSIONS |
CEI EN 50512 : 2014 | ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - ADVANCED VISUAL DOCKING GUIDANCE SYSTEMS (A-VDGS) |
NF EN 80601-2-30 : 2011 AMD 1 2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS |
OIML R 137-1 & 2 : 2012 AMD 2014 | GAS METERS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS; PART 2: METROLOGICAL CONTROLS AND PERFORMANCE TESTS |
ISO 12405-1:2011 | Electrically propelled road vehicles Test specification for lithium-ion traction battery packs and systems Part 1: High-power applications |
BIS IS/ISO 15197 : 2013 | IN VITRO DIAGNOSTIC TEST SYSTEMS - REQUIREMENTS FOR BLOOD-GLUCOSE MONITORING SYSTEM FOR SELF-TESTING IN MANAGING DIABETES MELLITUS |
DIN EN 12405-3:2016-04 | Gas meters - Conversion devices - Part 3: Flow computer |
CSA Z9919 : 2007 : R2012 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE |
CEI EN 62660-2 : 2014 | SECONDARY LITHIUM-ION CELLS FOR THE PROPULSION OF ELECTRIC ROAD VEHICLES - PART 2: RELIABILITY AND ABUSE TESTING |
I.S. EN 60068-2-55:2013 | ENVIRONMENTAL TESTING - PART 2-55: TESTS - TEST EE AND GUIDANCE - LOOSE CARGO TESTING INCLUDING BOUNCE (IEC 60068-2-55:2013 (EQV)) |
SAE USCAR 34 : 2009 | SPECIFICATION FOR TESTING AUTOMOTIVE LAMP ASSEMBLIES |
I.S. EN 61810-7:2006 | ELECTROMECHANICAL ELEMENTARY RELAYS - PART 7: TEST AND MEASUREMENT PROCEDURES |
I.S. EN 62745:2017 | SAFETY OF MACHINERY - REQUIREMENTS FOR CABLELESS CONTROL SYSTEMS OF MACHINERY |
I.S. EN 60068-2-6:2008 | ENVIRONMENTAL TESTING - PART 2-6: TESTS - TEST FC: VIBRATION (SINUSOIDAL) |
BS EN ISO 80601-2-12:2011 | Medical electrical equipment Particular requirements for basic safety and essential performance of critical care ventilators |
I.S. EN 61163-1:2006 | RELIABILITY STRESS SCREENING - PART 1: REPAIRABLE ASSEMBLIES MANUFACTURED IN LOTS |
BS EN ISO 80601-2-61:2011 | Medical electrical equipment Particular requirements for basic safety and essential performance of pulse oximeter equipment |
OIML D 11 : 2013 | GENERAL REQUIREMENTS FOR MEASURING INSTRUMENTS - ENVIRONMENTAL CONDITIONS |
I.S. EN 62575-1:2016 | RADIO FREQUENCY (RF) BULK ACOUSTIC WAVE (BAW) FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
PREN 15834 : DRAFT 2008 | REFRIGERATING SYSTEMS AND HEAT PUMPS - QUALIFICATION OF TIGHTNESS OF COMPONENTS AND JOINTS |
17/30358367 DC : 0 | BS EN 17128 - NON-APPROVED LIGHT MOTORIZED VEHICLES FOR THE TRANSPORTATION OF PERSONS AND GOODS AND RELATED FACILITIES - PERSONAL LIGHT ELECTRIC VEHICLES (PLEV) - SAFETY REQUIREMENTS AND TEST METHODS |
NF EN 45502-2-3 : 2010 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-3: PARTICULAR REQUIREMENTS FOR COCHLEAR AND AUDITORY BRAINSTEM IMPLANT SYSTEMS |
NF EN 60068-2-57 : 2013 | ENVIRONMENTAL TESTING - PART 2-57: TESTS - TEST FF: VIBRATION - TIME-HISTORY AND SINE-BEAT METHOD |
I.S. EN 60068-2-57:2013 | ENVIRONMENTAL TESTING - PART 2-57: TESTS - TEST FF: VIBRATION - TIME-HISTORY AND SINE-BEAT METHOD (IEC 60068-2-57:2013 (EQV)) |
I.S. EN 45502-2-2:2008 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS) |
I.S. EN 60068-2-81:2003 | ENVIRONMENTAL TESTING - PART 2-81: TESTS - TEST EI: SHOCK - SHOCK RESPONSE SPECTRUM SYNTHESIS |
I.S. EN 50512:2009 | ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - ADVANCED VISUAL DOCKING GUIDANCE SYSTEMS (A-VDGS) |
DIN EN 12368:2015-09 | Traffic control equipment - Signal heads |
DIN EN 13763-26:2004-11 | Explosives for civil uses - Detonators and relays - Part 26: Definitions, methods and requirements for devices and accessories for reliable and safe function of detonators and relays; German version EN 13763-26:2004 |
BS EN 12966-1 : 2005 | ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS - PART 1: PRODUCT STANDARD |
UNE-EN ISO 13355:2016 | Packaging - Complete, filled transport packages and unit loads - Vertical random vibration test (ISO 13355:2016) |
BS EN 13718-1:2014 | Medical vehicles and their equipment. Air ambulances Requirements for medical devices used in air ambulances |
IEC 62752:2016 | In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD) |
BS EN 13763-26:2004 | Explosives for civil uses. Detonators and relays Definitions, methods and requirements for devices and accessories for reliable and safe functioning of detonators and relays |
BS EN 280 : 2013 | MOBILE ELEVATING WORK PLATFORMS - DESIGN CALCULATIONS - STABILITY CRITERIA - CONSTRUCTION - SAFETY - EXAMINATIONS AND TESTS |
IEC 60068-2-80:2005 | Environmental testing - Part 2-80: Tests - Test Fi: Vibration - Mixed mode |
CEN/TS 14507-1:2003 | Inhalational nitric oxide systems - Part 1: Delivery systems |
DIN EN 14154-2:2011-06 | WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE |
EN 61019-1:2005 | Surface acoustic wave (SAW) resonators - Part 1: Generic specification |
EN 12368:2015 | Traffic control equipment - Signal heads |
DIN EN ISO 4064-2:2017-10 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS (ISO 4064-2:2014) |
EN 60068-2-81:2003 | Environmental testing - Part 2-81: Tests - Test Ei: Shock - Shock response spectrum synthesis |
DIN EN ISO 21649:2010-01 | Needle-free injectors for medical use - Requirements and test methods (ISO 21649:2006) |
EN 62604-1:2015 | Surface acoustic wave (SAW) and bulk acoustic wave (BAW) duplexers of assessed quality - Part 1: Generic specification |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
EN 61753-101-3:2008 | Fibre optic interconnecting devices and passive components performance standard - Part 101-3: Fibre management systems for Category U - Uncontrolled environment |
EN 62878-1-1:2015 | Device embedded substrate - Part 1-1: Generic specification - Test methods |
EN 61163-1 : 2006 | RELIABILITY STRESS SCREENING - PART 1: REPAIRABLE ASSEMBLIES MANUFACTURED IN LOTS |
EN ISO 21647:2009 | Medical electrical equipment - Particular requirements for the basic safety and essential performance of respiratory gas monitors (ISO 21647:2004, including Cor 1:2005) |
EN 12966-1:2005+A1:2009 | Road vertical signs - Variable message traffic signs - Part 1: Product standard |
HD 638 S1:2001/A1:2006 | ROAD TRAFFIC SIGNAL SYSTEMS |
EN 13557:2003+A2:2008 | Cranes - Controls and control stations |
DIN ISO 10109-12:2005-08 | OPTICS AND OPTICAL INSTRUMENTS - ENVIRONMENTAL REQUIREMENTS - PART 12: CONDITIONS OF TRANSPORT FOR OPTICAL INSTRUMENTS |
IPC 9592 : B | REQUIREMENTS FOR POWER CONVERSION DEVICES FOR THE COMPUTER AND TELECOMMUNICATIONS INDUSTRIES |
ONORM EN ISO 11608-4 : 2007 | PEN-INJECTORS FOR MEDICAL USE - PART 4: REQUIREMENTS AND TEST METHODS FOR ELECTRONIC AND ELECTROMECHANICAL PEN-INJECTORS |
NF EN ISO 21649 : 2009 | NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS |
ISO 14708-1:2014 | Implants for surgery — Active implantable medical devices — Part 1: General requirements for safety, marking and for information to be provided by the manufacturer |
04/30031093 DC : DRAFT FEB 2004 | ISO 4064-3 - MEASUREMENT OF WATER FLOW IN CLOSED FULLY CHARGED CONDUITS - METERS FOR COLD POTABLE WATER AND HOT WATER - PART 3: TEST METHODS AND EQUIPMENT |
IEC 61587-1:2016 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation |
14/30284930 DC : 0 | BS EN 62689-2 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: GENERAL PRINCIPLES AND REQUIREMENTS |
BS EN 16084:2011 | Refrigerating systems and heat pumps. Qualification of tightness of components and joints |
15/30280758 DC : 0 | BS EN 62745 - SAFETY OF MACHINERY - GENERAL REQUIREMENTS FOR CABLELESS CONTROL SYSTEMS OF MACHINERY |
BS EN 62660-2:2011 | Secondary lithium-ion cells for the propulsion of electric road vehicles Reliability and abuse testing |
ISO 17593:2007 | Clinical laboratory testing and in vitro medical devices Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy |
PD IEC TR 60721-4-7:2001 | Classification of environmental conditions. Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 Portable and non-stationary use |
BS EN 62326-20:2016 | Printed boards Printed circuit boards for high-brightness LEDs |
PD IEC/TR 60721-4-2:2002 | Classification of environmental conditions. Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 Transportation |
16/30338439 DC : 0 | BS EN ISO 14903 - REFRIGERATING SYSTEMS AND HEAT PUMPS - QUALIFICATION OF TIGHTNESS OF COMPONENTS AND JOINTS |
BS EN 61753-101-3:2009 | Fibre optic interconnecting devices and passive components performance standard Fibre management systems for category U. Uncontrolled environment |
DD CEN/TS 14507-1:2003 | Inhalational nitric oxide systems Delivery systems |
10/30215327 DC : DRAFT DEC 2010 | BS ISO 12405-2 - ELECTRICALLY PROPELLED ROAD VEHICLES - TEST SPECIFICATION FOR LITHIUM-ION TRACTION BATTERY SYSTEMS - PART 2: HIGH ENERGY APPLICATIONS |
AAMI IEC 80601-2-30 : 2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS |
06/30159993 DC : 0 | BS EN 61373 - RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS |
I.S. EN 16084:2011 | REFRIGERATING SYSTEMS AND HEAT PUMPS - QUALIFICATION OF TIGHTNESS OF COMPONENTS AND JOINTS |
BS EN 62745:2017 | Safety of machinery. Requirements for cableless control systems of machinery |
BS ISO 9022-22:2012 | Optics and photonics. Environmental test methods Combined cold, dry heat or temperature change with bump or random vibration |
03/114562 DC : DRAFT SEP 2003 | BS EN ISO 18777 - TRANSPORTABLE LIQUID OXYGEN SYSTEMS FOR MEDICAL USE - PARTICULAR REQUIREMENTS |
BS EN 16882:2016 | Road vehicles. Security of the mechanical seals used on tachographs. Requirements and test procedures |
13/30275356 DC : 0 | BS EN 12966 - ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS |
UNI EN ISO 80601-2-12 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
02/210375 DC : DRAFT DEC 2002 | IEC 60068-2-80 ED.1 - ENVIRONMENTAL TESTING - PART 2: TEST METHODS - TEST F(?) - MIXED MODE TESTING |
03/111582 DC : DRAFT JULY 2003 | BS EN ISO 18779 - DEVICES FOR CONSERVING OXYGEN AND OXYGEN MIXTURES - PARTICULAR REQUIREMENTS |
BS EN 60862-1:2015 | Surface acoustic wave (SAW) filters of assessed quality Generic specification |
BS EN 45502-2-3:2010 | Active implantable medical devices Particular requirements for cochlear and auditory brainstem implant systems |
S.R. CEN ISO/TS 14907-1:2015 | ELECTRONIC FEE COLLECTION - TEST PROCEDURES FOR USER AND FIXED EQUIPMENT - PART 1: DESCRIPTION OF TEST PROCEDURES (ISO/TS 14907-1:2015) |
CEI EN 61373 : 2012 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS |
OIML R 144-2 : 2013 | INSTRUMENTS FOR CONTINUOUS MEASUREMENT OF CO, NO[X] IN STATIONARY SOURCE EMISSIONS - PART 2: METROLOGICAL AND PERFORMANCE TESTS |
CEI EN 50249 : 2003 | ELECTROMAGNETIC LOCATORS FOR BURIED PIPES AND CABLES - PERFORMANCE AND SAFETY |
UNE-EN ISO 4064-2:2015 | Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-2:2014) |
03/111581 DC : DRAFT JULY 2003 | BS EN ISO 18778 - INFANT MONITORS - PARTICULAR REQUIREMENTS |
09/30181956 DC : DRAFT MAY 2009 | BS ISO 80601-2-61 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE |
BS EN 60068-2-55:2013 | Environmental testing Tests. Test Ee and guidance. Loose cargo testing including bounce |
I.S. EN 12966:2014 | ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS |
NF EN 60601-1-11 : 2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT |
CSA Z21647 : 2007 : R2012 : FR | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
UNE-EN 12405-3:2016 | Gas meters - Conversion devices - Part 3: Flow computer |
DIN EN 16084:2011-07 | REFRIGERATING SYSTEMS AND HEAT PUMPS - QUALIFICATION OF TIGHTNESS OF COMPONENTS AND JOINTS |
IEC 62327:2017 | Radiation protection instrumentation - Hand-held instruments for the detection and identification of radionuclides and for the estimation of ambient dose equivalent rate from photon radiation |
ISO 16750-3:2012 | Road vehicles — Environmental conditions and testing for electrical and electronic equipment — Part 3: Mechanical loads |
IEC TR 60721-4-5:2001+AMD1:2003 CSV | Classification of environmental conditions - Part 4-5: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Ground vehicle installations |
UNE-EN ISO 20072:2013 | Aerosol drug delivery device design verification - Requirements and test methods (ISO 20072:2009) |
BS ISO 15003:2006 | Agricultural engineering. Electrical and electronic equipment. Testing resistance to environmental conditions |
IEC 60605-3-5:1996 | Equipment reliability testing - Part 3: Preferred test conditions - Section 5: Test cycle 5: Ground mobile equipment - Low degree of simulation |
I.S. EN 61019-1:2005 | SURFACE ACOUSTIC WAVE (SAW) RESONATORS - PART 1: GENERIC SPECIFICATION |
I.S. EN 60679-1:2017 | PIEZOELECTRIC, DIELECTRIC AND ELECTROSTATIC OSCILLATORS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
I.S. EN 60068-2-80:2005 | ENVIRONMENTAL TESTING - PART 2-80: TESTS - TEST FI: VIBRATION - MIXED MODE |
EN 62884-1:2017 | Measurement techniques of piezoelectric, dielectric and electrostatic oscillators - Part 1: Basic methods for the measurement |
I.S. EN 62759-1:2015 | PHOTOVOLTAIC (PV) MODULES - TRANSPORTATION TESTING - PART 1: TRANSPORTATION AND SHIPPING OF MODULE PACKAGE UNITS |
NF EN 50512 : 2009 | ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - ADVANCED VISUAL DOCKING GUIDANCE SYSTEMS (A-VDGS) |
UNI EN ISO 80601-2-55 : 2012 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
OIML R 80-2 : 2017 | ROAD AND RAIL TANKERS WITH LEVEL GAUGING - PART 2: METROLOGICAL CONTROLS AND TESTS |
BIS IS/ISO 14708-1 : 2000 | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND FOR INFORMATION TO BE PROVIDED BY THE MANUFACTURER |
CSA E62660-2 : 2015 | SECONDARY LITHIUM-ION CELLS FOR THE PROPULSION OF ELECTRIC ROAD VEHICLES - PART 2: RELIABILITY AND ABUSE TESTING |
EN ISO 14903:2017 | Refrigerating systems and heat pumps - Qualification of tightness of components and joints (ISO 14903:2017) |
CSA C22.2 No. 80601-2-12 : 2012 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
ISO 15442:2012 | Cranes — Safety requirements for loader cranes |
NF EN 60068-2-53 : 2010 | ENVIRONMENTAL TESTING - PART 2-53: TESTS AND GUIDANCE: COMBINED CLIMATIC (TEMPERATURE/HUMIDITY) AND DYNAMIC (VIBRATION/SHOCK) TESTS |
NF EN 60601-1-12 : 2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-12: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS INTENDED FOR USE THE EMERGENCY MEDICAL SERVICES ENVIRONMENT |
I.S. EN 60368-1:2000 | PIEZOELECTRIC FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
IEC TS 62271-210:2013 | High-voltage switchgear and controlgear - Part 210: Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV |
IEC 80601-2-30:2018 | Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers |
IEC 60605-3-6:1996 | Equipment reliability testing - Part 3: Preferred test conditions - Section 6: Test cycle 6: Outdoor transportable equipment - Low degree of simulation |
IEC TR 62131-5:2015 | Environmental conditions - Vibration and shock of electotechnical equipment - Part 5: Equipment during storage and handling |
IEC 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
DIN EN ISO 18778:2009-08 | Respiratory equipment - Infant monitors - Particular requirements (ISO 18778:2005) |
BS EN 45502-1:2015 | Implants for surgery. Active implantable medical devices General requirements for safety, marking and for information to be provided by the manufacturer |
BS EN 12368:2015 | Traffic control equipment. Signal heads |
IEC 61163-1:2006 | Reliability stress screening - Part 1: Repairable assemblies manufactured in lots |
UNE-EN 62759-1:2016 | Photovoltaic (PV) modules - Transportation testing - Part 1: Transportation and shipping of module package units |
BS EN 62694:2016 | Radiation protection instrumentation. Backpack-type radiation detector (BRD) for the detection of illicit trafficking of radioactive material |
DIN EN ISO 11608-4:2016-03 (Draft) | PEN-INJECTORS FOR MEDICAL USE - PART 4: REQUIREMENTS AND TEST METHODS FOR ELECTRONIC AND ELECTROMECHANICAL PEN-INJECTORS |
I.S. EN ISO 15197:2015 | IN VITRO DIAGNOSTIC TEST SYSTEMS - REQUIREMENTS FOR BLOOD-GLUCOSE MONITORING SYSTEMS FOR SELF-TESTING IN MANAGING DIABETES MELLITUS (ISO 15197:2013) |
I.S. EN 12368:2015 | TRAFFIC CONTROL EQUIPMENT - SIGNAL HEADS |
I.S. EN ISO 21649:2009 | NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS |
I.S. EN 1808:2015 | SAFETY REQUIREMENTS FOR SUSPENDED ACCESS EQUIPMENT - DESIGN CALCULATIONS, STABILITY CRITERIA, CONSTRUCTION - EXAMINATIONS AND TESTS |
I.S. EN ISO 18778:2009 | RESPIRATORY EQUIPMENT - INFANT MONITORS - PARTICULAR REQUIREMENTS |
I.S. EN ISO 13355:2016 | PACKAGING - COMPLETE, FILLED TRANSPORT PACKAGES AND UNIT LOADS - VERTICAL RANDOM VIBRATION TEST |
UNI EN 13718-1 : 2014 | MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES |
I.S. EN 13557:2003 | CRANES - CONTROLS AND CONTROL STATIONS |
DIN EN 1789:2014-12 | MEDICAL VEHICLES AND THEIR EQUIPMENT - ROAD AMBULANCES |
I.S. EN 45502-1:2015 | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND FOR INFORMATION TO BE PROVIDED BY THE MANUFACTURER |
I.S. EN 280:2013 | MOBILE ELEVATING WORK PLATFORMS - DESIGN CALCULATIONS - STABILITY CRITERIA - CONSTRUCTION - SAFETY - EXAMINATIONS AND TESTS |
I.S. EN ISO 18779:2005 | MEDICAL DEVICES FOR CONSERVING OXYGEN AND OXYGEN MIXTURES - PARTICULAR REQUIREMENTS |
EN 45502-2-2 : 2008 COR 2009 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS) |
DIN EN 16882:2017-06 | ROAD VEHICLES - SECURITY OF THE MECHANICAL SEALS USED ON TACHOGRAPHS - REQUIREMENTS AND TEST PROCEDURES |
NF EN ISO 18778 : 2009 | RESPIRATORY EQUIPMENT - INFANT MONITORS - PARTICULAR REQUIREMENTS |
ISO 14903:2017 | Refrigerating systems and heat pumps — Qualification of tightness of components and joints |
CEI EN 60512-6-5 : 2001 | ELECTROMECHANICAL COMPONENTS FOR ELECTRONIC EQUIPMENT - BASIC TESTING PROCEDURES AND MEASURING METHODS PART 6: DYNAMIC STRESS TESTS SECTION 5: TEST 6E: RANDOM VIBRATION |
11/30217192 DC : 0 | BS EN ISO 4064-2 - WATER METERS INTENDED FOR THE METERING OF COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS |
OIML R 140 : 2007 | MEASURING SYSTEMS FOR GASEOUS FUEL |
ISO 80601-2-61:2017 | Medical electrical equipment Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment |
IEEE 1725-2011 | IEEE Standard for Rechargeable Batteries for Cellular Telephones |
10/30217405 DC : 0 | BS EN 50556 - ROAD TRAFFIC SIGNAL SYSTEMS |
09/30197590 DC : 0 | BS EN ISO 80601-2-55 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
BS EN 50249:2002 | Electromagnetic locators for buried pipes and cables. Performance and safety |
ISO 14708-7:2013 | Implants for surgery Active implantable medical devices Part 7: Particular requirements for cochlear implant systems |
14/30296572 DC : 0 | BS EN 60601-1-11 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT |
I.S. EN ISO 9919:2009 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE |
08/30191609 DC : DRAFT DEC 2008 | BS ISO 14708-6 - IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 6: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDING IMPLANTABLE DEFIBRILLATORS) |
DIN ISO 9022-3:2015-08 | Optics and photonics - Environmental test methods - Part 3: Mechanical stress (ISO 9022-3:2015) |
BS EN 50512:2009 | Electrical installations for lighting and beaconing of aerodromes. Advanced visual docking guidance systems (A-VDGS) |
DIN CEN ISO/TS 14907-1;DIN SPEC 91192:2015-12 | ELECTRONIC FEE COLLECTION - TEST PROCEDURES FOR USER AND FIXED EQUIPMENT - PART 1: DESCRIPTION OF TEST PROCEDURES (ISO/TS 14907-1:2015) |
UNE-EN 50512:2011 | Electrical installations for lighting and beaconing of aerodromes - Advanced Visual Docking Guidance Systems (A-VDGS) |
BS EN ISO 4064-2:2017 | Water meters for cold potable water and hot water Test methods |
12/30252220 DC : DRAFT MAR 2012 | BS EN 62604-1 - SURFACE ACOUSTIC WAVE (SAW) AND BULK ACOUSTIC WAVE (BAW) DUPLEXERS - PART 1: GENERIC SPECIFICATION |
05/30123158 DC : DRAFT MAY 2005 | ISO 16750-3 - ROAD VEHICLES - ENVIRONMENTAL CONDITIONS AND TESTING FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PART 3: MECHANICAL LOADS |
ISO 15003:2006 | Agricultural engineering Electrical and electronic equipment Testing resistance to environmental conditions |
11/30243761 DC : 0 | BS ISO 14708-7 - IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 7: PARTICULAR REQUIREMENTS FOR COCHLEAR IMPLANT SYSTEMS |
08/30181001 DC : DRAFT APR 2008 | BS EN 50512 - ELECTRICAL INSTALLATIONS FOR LIGHTING AND BEACONING OF AERODROMES - ADVANCED VISUAL DOCKING GUIDANCE SYSTEMS (A-VDGS) |
BS EN 60068-2-6:2008 | Environmental testing Tests. Test Fc. Vibration (sinusoidal) |
EN 61373:2010/AC:2017-09 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS (IEC 61373:2010) |
XP CEN/TS 14507-1 : 2003 XP | INHALATION NITRIC OXIDE SYSTEMS - PART 1 : DELIVERY SYSTEMS |
UNI CEI EN ISO 4064-2 : 2014 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS |
BS EN 61019-1:2005 | Surface acoustic wave (SAW) resonators Generic specification |
95/101341 DC : DRAFT FEB 1995 | PREN 1823 - EMERGENCY ROADSIDE TELEPHONES |
BS ISO 13355 : 2001 AMD 15247 | PACKAGING - COMPLETE, FILLED TRANSPORT PACKAGES AND UNIT LOADS - VERTICAL RANDOM VIBRATION TEST |
BS EN 60679-1:2017 | Piezoelectric, dielectric and electrostatic oscillators of assessed quality Generic specification |
CEI 56-22 : 2000 | EQUIPMENT RELIABILITY TESTING - PART 3: PREFERRED TEST CONDITIONS - SECTION 6: TEST CYCLE 6: OUTDOOR TRANSPORTABLE EQUIPMENT - LOW DEGREE OF SIMULATION |
11/30249027 DC : 0 | BS ISO 15442 - CRANES - SAFETY REQUIREMENTS FOR LOADER CRANES |
CEI EN 60368-1 : 2006 | PIEZOELECTRIC FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
OIML R 137-1 : 2006 | GAS METERS - PART 1: REQUIREMENTS |
BS ISO 9022-3:2015 | Optics and photonics. Environmental test methods Mechanical stress |
BIS IS/IEC 60862-1 : 2003 | SURFACE ACOUSTIC WAVE (SAW) FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
CEI EN 61587-1 : 2012 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION |
CSA Z18779 : 2008 : R2013 | MEDICAL DEVICES FOR CONSERVING OXYGEN AND OXYGEN MIXTURES - PARTICULAR REQUIREMENTS |
PREN 12966 : DRAFT 2013 | ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS |
UNI EN ISO 20072 : 2013 | AEROSOL DRUG DELIVERY DEVICE DESIGN VERIFICATION - REQUIREMENTS AND TEST METHODS |
BS EN 60368-1:2000 | Piezoelectric filters Generic specification |
CEI EN 62884-1 : 1ED 2018 | MEASUREMENT TECHNIQUES OF PIEZOELECTRIC, DIELECTRIC AND ELECTROSTATIC OSCILLATORS - PART 1: BASIC METHODS FOR THE MEASUREMENT |
BS EN 45502-2-2:2008 | Active implantable medical devices Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (includes implantable defibrillators) |
CSA Z18778 :2008 | RESPIRATORY EQUIPMENT - INFANT MONITORS - PARTICULAR REQUIREMENTS |
CSA Z9919 :2007 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE |
CSA C22.2 No. 80601-2-30 : 2010 : INC : COR 1 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS |
CSA C22.2 No. 80601-2-30 : 2010FR | MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS |
SAE USCAR 27 : 2007 | SPECIFICATION FOR TESTING GAS DISCHARGE LIGHT SOURCE SUBSYSTEM |
CSA C22.2 No. 80601-2-30 : 2010 : R2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS |
BS 5760-13.6:1997 | Reliability of systems, equipment and components. Guide to reliability test conditions for consumer equipment Outdoor transportable equipment. Low degree of simulation |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
I.S. EN 16882:2016 | ROAD VEHICLES - SECURITY OF THE MECHANICAL SEALS USED ON TACHOGRAPHS - REQUIREMENTS AND TEST PROCEDURES |
I.S. EN 61643-11:2012 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TESTS METHODS |
I.S. EN 12405-3:2015 | GAS METERS - CONVERSION DEVICES - PART 3: FLOW COMPUTER |
I.S. EN 62752:2016/AC:2019-03 | IN-CABLE CONTROL AND PROTECTION DEVICE FOR MODE 2 CHARGING OF ELECTRIC ROAD VEHICLES (IC-CPD) |
I.S. EN 80601-2-30:2010 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS |
ISO 19453-3:2018 | Road vehicles — Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles — Part 3: Mechanical loads |
I.S. EN 60601-1-12:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-12: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS INTENDED FOR USE IN THE EMERGENCY MEDICAL SERVICES ENVIRONMENT |
AAMI ISO 14708-5 : 2010 | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 5: CIRCULATORY SUPPORT DEVICES |
CEI EN 60122-1 : 2004 | QUARTZ CRYSTAL UNITS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
UNE-EN 16084:2011 | Refrigerating systems and heat pumps - Qualification of tightness of components and joints |
OIML R 139 : 2007 | COMPRESSED GASEOUS FUEL MEASURING SYSTEMS FOR VEHICLES |
OIML R 49-2 : 2013 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS |
ISO 14708-6:2010 | Implants for surgery Active implantable medical devices Part 6: Particular requirements for active implantable medical devices intended to treat tachyarrhythmia (including implantable defibrillators) |
NF EN 50556 : 2011 | ROAD TRAFFIC SIGNAL SYSTEMS |
CEI EN 61753-101-2 : 2007 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS PERFORMANCE STANDARD - PART 101-2: FIBRE MANAGEMENT SYSTEMS FOR CATEGORY C - CONTROLLED ENVIRONMENT |
I.S. EN 62884-1:2017 | MEASUREMENT TECHNIQUES OF PIEZOELECTRIC, DIELECTRIC AND ELECTROSTATIC OSCILLATORS - PART 1: BASIC METHODS FOR THE MEASUREMENT |
OIML R 126 : 2012 | EVIDENTIAL BREATH ANALYZERS |
NF EN 300019 2-3 : 2016 | ENVIRONMENTAL ENGINEERING (EE) - ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - PART 2-3: SPECIFICATION OF ENVIRONMENTAL TESTS - STATIONARY USE AT WEATHERPROTECTED LOCATIONS (V2.4.1) |
NF EN ISO 80601-2-61 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT |
ISO 17089-1:2010 | Measurement of fluid flow in closed conduits - Ultrasonic meters for gas Part 1: Meters for custody transfer and allocation measurement |
IEC 60068-3-8:2003 | Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests |
EN ISO 80601-2-55:2018 | Medical electrical equipment - Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors (ISO 80601-2-55:2018) |
ISO 14708-2:2012 | Implants for surgery Active implantable medical devices Part 2: Cardiac pacemakers |
ISO 80601-2-55:2018 | Medical electrical equipment — Part 2-55: Particular requirements for the basic safety and essential performance of respiratory gas monitors |
IEC TR 60721-4-2:2001+AMD1:2003 CSV | Classification of environmental conditions - Part 4-2: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Transportation |
IEC 60679-1:2017 | Piezoelectric, dielectric and electrostatic oscillators of assessed quality - Part 1: Generic specification |
I.S. EN 61587-1:2017 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 SERIES - PART 1: ENVIRONMENTAL REQUIREMENTS, TEST SET-UP AND SAFETY ASPECTS FOR CABINETS, RACKS, SUBRACKS AND CHASSIS UNDER INDOOR CONDITION USE AND TRANSPORTATION |
DIN EN 1808:2015-08 | SAFETY REQUIREMENTS FOR SUSPENDED ACCESS EQUIPMENT - DESIGN CALCULATIONS, STABILITY CRITERIA, CONSTRUCTION - EXAMINATIONS AND TESTS |
UNE-EN 50491-2:2011 | General requirements for Home and Building Electronic Systems (HBES) and Building Automation and Control Systems (BACS) -- Part 2: Environmental conditions |
DIN EN 13718-1:2014-12 | MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES |
BS EN ISO 9919:2009 | Medical electrical equipment. Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use |
ISO 18779:2005 | Medical devices for conserving oxygen and oxygen mixtures Particular requirements |
IEC 60368-1:2000+AMD1:2004 CSV | Piezoelectric filters of assessed quality - Part 1: Genericspecification |
BS EN ISO 21649:2009 | Needle-free injectors for medical use. Requirements and test methods |
ISO 15197:2013 | In vitro diagnostic test systems — Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus |
BS EN ISO 13355:2003 | Packaging. Complete, filled transport packages and unit loads. Vertical random vibration test |
BS EN 14154-2 : 2005 | WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE |
ISO 21649:2006 | Needle-free injectors for medical use — Requirements and test methods |
IEC 62575-1:2015 | Radio frequency (RF) bulk acoustic wave (BAW) filters of assessed quality - Part 1: Generic specification |
BS EN ISO 15197:2015 | In vitro diagnostic test systems. Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus |
I.S. EN 1789:2007 | MEDICAL VEHICLES AND THEIR EQUIPMENT - ROAD AMBULANCES |
EN 1789:2007+A2:2014 | Medical vehicles and their equipment - Road ambulances |
UNE-EN 14154-2:2005 | Water meters - Part 2 : Installation and conditions of use |
EN 60601-1-12:2015 | Medical electrical equipment - Part 1-12: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems intended for use in the emergency medical services environment |
UNE-EN 12966-1:2006 | Road vertical signs - Variable message traffic signs - Part 1: Product standard |
CSA C22.2 No. 80601-2-12 : 2012(R2017) | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
EN 13763-26:2004 | Explosives for civil uses - Detonators and relays - Part 26: Definitions, methods, and requirements for devices and accessories for reliable and safe function of detonators and relays |
UNI EN 13557 : 2008 | CRANES - CONTROLS AND CONTROL STATIONS |
UNI EN ISO 21647 : 2009 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
EN 45502-1:2015 | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND FOR INFORMATION TO BE PROVIDED BY THE MANUFACTURER |
I.S. EN ISO 11608-4:2007 | PEN-INJECTORS FOR MEDICAL USE - PART 4: REQUIREMENTS AND TEST METHODS FOR ELECTRONIC AND ELECTROMECHANICAL PEN-INJECTORS |
EN ISO 9919:2009 | Medical electrical equipment - Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use (ISO 9919:2005) |
UNI EN ISO 9919 : 2009 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE |
UNI EN 14154-2 : 2011 | WATER METERS - PART 2: INSTALLATION AND CONDITIONS OF USE |
UNI CEI EN 45502-2-3 : 2010 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-3: PARTICULAR REQUIREMENTS FOR COCHLEAR AND AUDITORY BRAINSTEM IMPLANT SYSTEMS |
UNI EN ISO 18778 : 2009 | RESPIRATORY EQUIPMENT - INFANT MONITORS - PARTICULAR REQUIREMENTS |
NF EN 300019 2-4 : 2016 | ENVIRONMENTAL ENGINEERING (EE) - ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - PART 2-4: SPECIFICATION OF ENVIRONMENTAL TESTS - STATIONARY USE AT NON-WEATHERPROTECTED LOCATIONS (V2.4.1) |
BS ISO 15442:2012+A1:2015 | Cranes. Safety requirements for loader cranes |
ANSI/AAMI HA60601-1-11:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT |
DIN EN ISO 20072:2013-10 | AEROSOL DRUG DELIVERY DEVICE DESIGN VERIFICATION - REQUIREMENTS AND TEST METHODS (ISO 20072:2009) |
BS EN 62604-1:2015 | Surface acoustic wave (SAW) and bulk acoustic wave (BAW) duplexers of assessed quality Generic specification |
BS EN ISO 20072:2013 | Aerosol drug delivery device design verification. Requirements and test methods |
08/30192448 DC : DRAFT DEC 2008 | BS ISO 14708-5 - IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 5: CIRCULATORY SUPPORT DEVICES |
NF EN 50249 : 2003 | ELECTROMAGNETIC LOCATORS FOR BURIED PIPES AND CABLES - PERFORMANCE AND SAFETY |
UNI EN ISO 21649 : 2009 | NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS |
CEI EN 60068-2-55 : 2014 | ENVIRONMENTAL TESTING - PART 2-55: TESTS - TEST EE AND GUIDANCE: LOOSE CARGO TESTING INCLUDING BOUNCE |
17/30296020 DC : 0 | BS ISO 19453-3 - ROAD VEHICLES - ENVIRONMENTAL CONDITIONS AND TESTING FOR ELECTRICAL AND ELECTRONIC EQUIPMENT FOR DRIVE SYSTEM OF ELECTRIC PROPULSION VEHICLES - PART 3: MECHANICAL LOADS |
BS EN 61373:2010 | Railway applications. Rolling stock equipment. Shock and vibration tests |
I.S. EN ISO 21647:2009 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
PD IEC/TR 60721-4-0:2002 | Classification of environmental conditions. Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 Introduction |
11/30219041 DC : DRAFT APR 2011 | BS ISO 14903 - REFRIGERATING SYSTEMS AND HEAT PUMPS - QUALIFICATION OF TIGHTNESS OF COMPONENTS AND JOINTS |
BS ISO 10109-12:2004 | Optics and optical instruments. Environmental requirements Conditions of transport for optical instruments |
BS ISO 10813-1:2004 | Vibration generating machines. Guidance for selection Equipment for environmental testing |
EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
BS EN 12405-3:2015 | Gas meters. Conversion devices Flow computer |
PD IEC TR 60721-4-5:2002 | Classification of environmental conditions. Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 Ground vehicle installations |
02/708964 DC : DRAFT JULY 2002 | ISO/DIS 10813-1 - VIBRATION-GENERATING MACHINES - GUIDANCE FOR SELECTION - PART 1: EQUIPMENT FOR ENVIRONMENTAL TESTING |
IEEE 1909.1-2014 | IEEE Recommended Practice for Smart Grid Communications Equipment -- Test Methods and Installation Requirements |
10/30216541 DC : 0 | BS EN 60068-2-55 - ENVIRONMENTAL TESTING - PART 2-55: TESTS - TEST EE AND GUIDANCE: LOOSE CARGO TESTING INCLUDING BOUNCE |
OIML R 99-1 & 2 : 2008 | INSTRUMENTS FOR MEASURING VEHICLE EXHAUST EMISSIONS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS; PART 2: METROLOGICAL CONTROLS AND PERFORMANCE TESTS |
12/30245174 DC : 0 | BS EN 60601-1-12 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-12: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS INTENDED FOR USE IN THE EMERGENCY MEDICAL SERVICES ENVIRONMENT |
CEI 56-21 : 2000 | EQUIPMENT RELIABILITY TESTING - PART 3: PREFERRED TEST CONDITIONS - SECTION 5: TEST CYCLE 5: GROUND MOBILE EQUIPMENT - LOW DEGREE OF SIMULATION |
CSA C22.2 No. 60601-1-11 : 2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT |
OIML R 117-1 : 2007 | DYNAMIC MEASURING SYSTEMS FOR LIQUIDS OTHER THAN WATER - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
11/30240686 DC : 0 | BS ISO 16750-3 - ROAD VEHICLES - ENVIRONMENTAL CONDITIONS AND TESTING FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PART 3: MECHANICAL LOADS |
11/30208525 DC : 0 | BS EN ISO 15197 - IN VITRO DIAGNOSTIC TEST SYSTEMS - REQUIREMENTS FOR BLOOD-GLUCOSE MONITORING SYSTEMS FOR SELF-TESTING IN MANAGING DIABETES MELLITUS |
15/30322686 DC : 0 | BS EN 16882 - ROAD VEHICLES - SECURITY OF THE MECHANICAL SEALS USED ON TACHOGRAPHS - REQUIREMENTS AND TEST PROCEDURES |
BS EN 60068-3-8:2003 | Environmental testing Supporting documentation and guidance - Selecting amongst vibration tests |
NF EN 61753-101-3 : 2008 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS PERFORMANCE STANDARD - PART 101-3: FIBRE MANAGEMENT SYSTEMS FOR CATEGORY U - UNCONTROLLED ENVIRONMENT |
13/30264600 DC : 0 | BS EN 60747-14-8 ED 1.0 - SEMICONDUCTOR DEVICES - PART 14-8: SEMICONDUCTOR SENSORS - CAPACITIVE DEGRADATION SENSOR OF LIQUID |
OIML R 21 : 2007 | TAXIMETERS - METROLOGICAL AND TECHNICAL REQUIREMENTS, TEST PROCEDURES AND TEST REPORT FORMAT |
I.S. EN 61753-101-3:2008 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS PERFORMANCE STANDARD - PART 101-3: FIBRE MANAGEMENT SYSTEMS FOR CATEGORY U - UNCONTROLLED ENVIRONMENT |
BS EN 62878-1-1:2015 | Device embedded substrate Generic specification. Test methods |
13/30233325 DC : 0 | BS EN 45502-1 - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND INFORMATION TO BE PROVIDED BY THE MANUFACTURER |
09/30155521 DC : 0 | BS EN 60601-1-11 ED.1 - MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT |
BS EN 60068-2-53:2010 | Environmental testing Tests and guidance. Combined climatic (temperature/humidity) and dynamic (vibration/shock) tests |
08/30190666 DC : DRAFT NOV 2008 | BS ISO 7752-1 - CRANES - CONTROLS - LAYOUT AND CHARACTERISTICS - PART 1: GENERAL PRINCIPLES |
09/30185062 DC : 0 | BS EN 12966-1:2006/A1 - ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS - PART 1: PRODUCT STANDARD |
ISO 9022-3:2015 | Optics and photonics Environmental test methods Part 3: Mechanical stress |
CEI UNI EN 12966-1 : 2010 | ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS - PART 1: - PRODUCT STANDARD |
BS EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements |
PREN ISO 80601-2-55 : DRAFT 2009 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
BS ISO 17089-1:2019 | Measurement of fluid flow in closed conduits. Ultrasonic meters for gas Meters for custody transfer and allocation measurement |
BS EN 60122-1 : 2002 | QUARTZ CRYSTAL UNITS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
CSA ISO 15197 : 2015 | IN VITRO DIAGNOSTIC TEST SYSTEMS - REQUIREMENTS FOR BLOOD-GLUCOSE MONITORING SYSTEMS FOR SELF-TESTING IN MANAGING DIABETES MELLITUS |
04/30031075 DC : DRAFT FEB 2004 | ISO 4064-1 - MEASUREMENT OF WATER FLOW IN CLOSED FULLY CHARGED CONDUITS - METERS FOR COLD POTABLE WATER AND HOT WATER - PART 1: SPECIFICATIONS |
07/30145258 DC : 0 | BS ISO 20072 - AEROSOL DRUG DELIVERY DEVICES DESIGN VERIFICATION - REQUIREMENTS AND TEST METHODS |
CSA Z18778 : 2008 : R2013 | RESPIRATORY EQUIPMENT - INFANT MONITORS - PARTICULAR REQUIREMENTS |
NF EN ISO 80601-2-12 : 2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS |
BS EN 60068-2-80:2005 | Environmental testing Tests - Test Fi: Vibration. Mixed mode |
NF EN 45502-2-2 : 2008 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS) |
NF EN 301442 : 2010 | |
EN 300 019-2-1 : 2.2.1 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 2-1: SPECIFICATION OF ENVIRONMENTAL TESTS; STORAGE |
BS EN 61810-7:2006 | Electromechanical elementary relays Test and measurement procedures |
EN 300 019-2-2 : 2.3.1 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 2-2: SPECIFICATION OF ENVIRONMENTAL TESTS; TRANSPORTATION |
BS ISO 16750-3:2012 | Road vehicles. Environmental conditions and testing for electrical and electronic equipment Mechanical loads |
CSA Z21647:2007 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
CSA Z21647 : 2007 : R2012 | MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
UNI EN 16084 : 2011 | REFRIGERATING SYSTEMS AND HEAT PUMPS - QUALIFICATION OF TIGHTNESS OF COMPONENTS AND JOINTS |
I.S. EN 60068-3-8:2003 | ENVIRONMENTAL TESTING - PART 3-8: SUPPORTING DOCUMENTATION AND GUIDANCE - SELECTING AMONGST VIBRATION TESTS |
CSA C22.2 No. 80601-2-55 : 2014(R2019) | MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
UNI CEI EN 12966-1 : 2010 | ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS - PART 1: PRODUCT STANDARD |
NFC 70 238 : 2001 AMD 1 2006 | ROAD TRAFFIC SIGNAL SYSTEMS |
EN 60679-1:2017 | Piezoelectric, dielectric and electrostatic oscillators of assessed quality - Part 1: Generic specification |
I.S. EN 62660-2:2011 | SECONDARY LITHIUM-ION CELLS FOR THE PROPULSION OF ELECTRIC ROAD VEHICLES - PART 2: RELIABILITY AND ABUSE TESTING |
ANSI/AAMI/ISO 14708-1:2014 | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND FOR INFORMATION TO BE PROVIDED BY THE MANUFACTURER |
I.S. EN 62689-1:2016 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
I.S. EN ISO 4064-2:2017 | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS (ISO 4064-2:2014) |
ISO 14708-5:2010 | Implants for surgery Active implantable medical devices Part 5: Circulatory support devices |
ISO 10813-1:2004 | Vibration generating machines — Guidance for selection — Part 1: Equipment for environmental testing |
DIN EN ISO 4064-2:2016-09 (Draft) | WATER METERS FOR COLD POTABLE WATER AND HOT WATER - PART 2: TEST METHODS (ISO 4064-2:2014) |
ISO 10109-12:2004 | Optics and optical instruments Environmental requirements Part 12: Conditions of transport for optical instruments |
CEI EN 60068-2-6 : 2009 | ENVIRONMENTAL TESTING - PART 2-6: TESTS - TEST FC: VIBRATION (SINUSOIDAL) |
I.S. EN 60601-1-11:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-11: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS USED IN THE HOME HEALTHCARE ENVIRONMENT |
BS EN 61587-1:2017 | Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 series Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation |
CSA C22.2 No. 60601-1-12 : 2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 1-12: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE - COLLATERAL STANDARD: REQUIREMENTS FOR MEDICAL ELECTRICAL EQUIPMENT AND MEDICAL ELECTRICAL SYSTEMS INTENDED FOR USE IN THE EMERGENCY MEDICAL SERVICES ENVIRONMENT |
DIN EN 12966:2015-03 | ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS |
IEEE 802.3-2012 | IEEE Standard for Ethernet |
BIS IS 15444-1 : 2012(R2016) | RELIABILITY STRESS SCREENING - PART 1: REPAIRABLE ASSEMBLIES MANUFACTURED IN LOTS |
CEI EN 50556 : 2012 | ROAD TRAFFIC SIGNAL SYSTEMS |
CEI EN 61810-7 : 2006 | ELECTROMECHANICAL ELEMENTARY RELAYS - PART 7: TEST AND MEASUREMENT PROCEDURES |
ISO 9022-22:2012 | Optics and photonics — Environmental test methods — Part 22: Combined cold, dry heat or temperature change with bump or random vibration |
DIN EN 16882:2015-09 (Draft) | ROAD VEHICLES - SECURITY OF THE MECHANICAL SEALS USED ON TACHOGRAPHS - REQUIREMENTS AND TEST PROCEDURES |
EN ISO 80601-2-61:2011 | Medical electrical equipment - Part 2-61: Particular requirements for basic safety and essential performance of pulse oximeter equipment (ISO 80601-2-61:2011) |
I.S. EN ISO 80601-2-12:2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-12: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF CRITICAL CARE VENTILATORS (ISO 80601-2-12:2011/COR 1:2011) |
IEC TR 60721-4-7:2001+AMD1:2003 CSV | Classification of environmental conditions - Part 4-7: Guidance for the correlation and transformation of environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Portable and non-stationary use |
ISO 16368:2010 | Mobile elevating work platforms Design, calculations, safety requirements and test methods |
I.S. EN 60068-2-47:2005 | ENVIRONMENTAL TESTING - PART 2-47: TESTS - MOUNTING OF SPECIMENS FOR VIBRATION, IMPACT AND SIMILAR DYNAMIC TESTS |
IEC 60068-2-81:2003 | Environmental testing - Part 2-81: Tests - Test Ei: Shock - Shock response spectrum synthesis |
IEC 62884-1:2017 | Measurement techniques of piezoelectric, dielectric and electrostatic oscillators - Part 1: Basic methods for the measurement |
UNE-EN 280:2014 | Mobile elevating work platforms - Design calculations - Stability criteria - Construction - Safety - Examinations and tests |
IEC TR 60721-4-0:2002 | Classification of environmental conditions - Part 4-0: Guidance for the correlation and transformation of the environmental condition classes of IEC 60721-3 to the environmental tests of IEC 60068 - Introduction |
I.S. EN 62878-1-1:2015 | DEVICE EMBEDDED SUBSTRATE - PART 1-1: GENERIC SPECIFICATION - TEST METHODS |
ISO 12405-2:2012 | Electrically propelled road vehicles Test specification for lithium-ion traction battery packs and systems Part 2: High-energy applications |
ISO 80601-2-12:2011 | Medical electrical equipment Part 2-12: Particular requirements for basic safety and essential performance of critical care ventilators |
DIN EN ISO 15197:2015-12 | IN VITRO DIAGNOSTIC TEST SYSTEMS - REQUIREMENTS FOR BLOOD-GLUCOSE MONITORING SYSTEMS FOR SELF-TESTING IN MANAGING DIABETES MELLITUS (ISO 15197:2013) |
DIN EN 280:2016-04 | Mobile elevating work platforms - Design calculations - Stability criteria - Construction - Safety - Examinations and tests (includes Amendment A1:2015) |
ISO 18778:2005 | Respiratory equipment — Infant monitors — Particular requirements |
IEC 62604-1:2015 | Surface acoustic wave (SAW) and bulk acoustic wave (BAW) duplexers of assessed quality - Part 1: Generic specification |
IEC 61753-101-2:2006 | Fibre optic interconnecting devices and passive components performance standard - Part 101-2: Fibre management systems for Category C - Controlled environment |
EN 62752:2016 | In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD) |
BS EN ISO 18778:2009 | Respiratory equipment. Infant monitors. Particular requirements |
BS EN ISO 11608-4:2007 | Pen-injectors for medical use Requirements and test methods for electronic and electromechanical pen-injectors |
ISO 20072:2009 | Aerosol drug delivery device design verification Requirements and test methods |
ISO 4064-2:2014 | Water meters for cold potable water and hot water Part 2: Test methods |
EN 13718-1:2014 | Medical vehicles and their equipment - Air ambulances - Part 1: Requirements for medical devices used in air ambulances |
BS EN 1789 : 2007 | MEDICAL VEHICLES AND THEIR EQUIPMENT - ROAD AMBULANCES |
ISO/TS 14907-1:2015 | Electronic fee collection Test procedures for user and fixed equipment Part 1: Description of test procedures |
ISO 11608-4:2006 | Pen-injectors for medical use Part 4: Requirements and test methods for electronic and electromechanical pen-injectors |
IEC 62694:2014 | Radiation protection instrumentation - Backpack-type radiation detector (BRD) for the detection of illicit trafficking of radioactive material |
I.S. EN 13718-1:2014 | MEDICAL VEHICLES AND THEIR EQUIPMENT - AIR AMBULANCES - PART 1: REQUIREMENTS FOR MEDICAL DEVICES USED IN AIR AMBULANCES |
UNE-EN 1789:2007 | Medical vehicles and their equipment - Road ambulances |
IEC 61747-1:1998+AMD1:2003 CSV | Liquid crystal and solid-state display devices - Part 1: Generic specification |
IEC 60862-1:2015 | Surface acoustic wave (SAW) filters of assessed quality - Part 1: Generic specification |
IEC 60068-2-57:2013 | Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method |
IEC TR 62131-6:2017 | Environmental conditions - Vibration and shock of electrotechnical equipment - Part 6: Transportation by propeller aircraft |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 61019-1:2004 | Surface acoustic wave (SAW) resonators - Part 1: Generic specification |
BS EN 1808:2015 | Safety requirements for suspended access equipment. Design calculations, stability criteria, construction. Examinations and tests |
UNE-EN 45502-2-3:2010 | Active implantable medical devices -- Part 2-3: Particular requirements for cochlear and auditory brainstem implant systems |
IEC 62660-2:2010 | Secondary lithium-ion cells for the propulsion of electric road vehicles - Part 2: Reliability and abuse testing |
ISO 13355:2016 | Packaging Complete, filled transport packages and unit loads Vertical random vibration test |
ISO 21647:2004 | Medical electrical equipment Particular requirements for the basic safety and essential performance of respiratory gas monitors |
BS EN 50491-2 : 2010 | GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 2: ENVIRONMENTAL CONDITIONS |
UNE-EN 16882:2017 | Road vehicles - Security of the mechanical seals used on tachographs - Requirements and test procedures |
UNE-EN 12368:2015 | Traffic control equipment - Signal heads |
EN 60862-1:2015 | Surface acoustic wave (SAW) filters of assessed quality - Part 1: Generic specification |
EN 16882:2016 | Road vehicles - Security of the mechanical seals used on tachographs - Requirements and test procedures |
EN 1808:2015 | Safety requirements for suspended access equipment - Design calculations, stability criteria, construction - Examinations and tests |
EN 14154-2:2005+A2:2011 | Water meters - Part 2: Installation and conditions of use |
EN ISO 4064-2:2017 | Water meters for cold potable water and hot water - Part 2: Test methods (ISO 4064-2:2014) |
EN ISO 21649:2009 | Needle-free injectors for medical use - Requirements and test methods (ISO 21649:2006) |
EN ISO 15197:2015 | In vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus (ISO 15197:2013) |
IEC 80601-2-30:2018 RLV | Medical electrical equipment - Part 2-30: Particular requirements for the basic safety and essential performance of automated non-invasive sphygmomanometers |
EN ISO 18779:2005 | Medical devices for conserving oxygen and oxygen mixtures - Particular requirements (ISO 18779:2005) |
EN 45502-2-3:2010 | Active implantable medical devices - Part 2-3: Particular requirements for cochlear and auditory brainstem implant systems |
EN 16084:2011 | Refrigerating systems and heat pumps - Qualification of tightness of components and joints |
EN ISO 20072:2013 | Aerosol drug delivery device design verification - Requirements and test methods (ISO 20072:2009) |
EN ISO 18778:2009 | Respiratory equipment - Infant monitors - Particular requirements (ISO 18778:2005) |
EN ISO 13355:2016 | Packaging - Complete, filled transport packages and unit loads - Vertical random vibration test (ISO 13355:2016) |
EN 280:2013+A1:2015 | Mobile elevating work platforms - Design calculations - Stability criteria - Construction - Safety - Examinations and tests |
EN ISO 11608-4:2007 | Pen-injectors for medical use - Part 4: Requirements and test methods for electronic and electromechanical pen-injectors (ISO 11608-4:2006) |
I.S. EN ISO 80601-2-61:2011 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT |
BS EN 60601-1-11:2015 | Medical electrical equipment General requirements for basic safety and essential performance. Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment |
BS EN 50556:2011 | Road traffic signal systems |
EN 61587-1:2017 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 series - Part 1: Environmental requirements, test set-up and safety aspects for cabinets, racks, subracks and chassis under indoor condition use and transportation |
11/30219104 DC : DRAFT MAY 2011 | BS ISO 9022-22 - OPTICS AND PHOTONICS - ENVIRONMENTAL TEST METHODS - PART 22: COMBINED COLD, DRY HEAT OR TEMPERATURE CHANGE WITH BUMP OR RANDOM VIBRATION |
CSA C22.2 No. 80601-2-61 : 2014(R2019) | MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT |
PREN 45502-1 : DRAFT 2013 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND INFORMATION TO BE PROVIDED BY THE MANUFACTURER |
11/30243576 DC : DRAFT FEB 2011 | BS EN 62643-1 - ELECTROSTATIC MICRO ELECTRO MECHANICAL SYSTEMS (MEMS) OSCILLATORS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
BS ISO 12405-2:2012 | Electrically propelled road vehicles. Test specification for lithium-ion traction battery packs and systems High-energy applications |
I.S. EN 50491-2:2010 | GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 2: ENVIRONMENTAL CONDITIONS |
14/30289772 DC : 0 | BS EN 1789:2007+A1:2010/A2 - MEDICAL VEHICLES AND THEIR EQUIPMENT - ROAD AMBULANCES |
CEI EN 62752 : 1ED 2017 | IN-CABLE CONTROL AND PROTECTION DEVICE FOR MODE 2 CHARGING OF ELECTRIC ROAD VEHICLES (IC-CPD) |
BS ISO 14903:2012 | Refrigerating systems and heat pumps. Qualification of tightness of components and joints |
BS ISO 17593:2007 | Clinical laboratory testing and in vitro medical devices. Requirements for in vitro monitoring systems for self-testing of oral anticoagulant therapy |
13/30264596 DC : 0 | BS EN 60747-14-7 ED 1.0 - SEMICONDUCTOR DEVICES - PART 14-7: SEMICONDUCTOR SENSORS - FLOW METER |
BS EN 61753-101-2:2006 | Fibre optic interconnecting devices and passive components performance standard Fibre management systems for category C. Controlled environment |
BS EN 61163-1:2006 | Reliability stress screening Repairable assemblies manufactured in lots |
PD IEC/TR 62131-5:2015 | Environmental conditions. Vibration and shock of electrotechnical equipment Equipment during storage and handling |
BS EN 62759-1:2015 | Photovoltaic (PV) modules. Transportation testing Transportation and shipping of module package units |
I.S. EN 50556:2011 | ROAD TRAFFIC SIGNAL SYSTEMS |
C22.2 NO. 300-18 | Portable power equipment |
PD IEC/TR 62131-6:2017 | Environmental conditions. Vibration and shock of electrotechnical equipment Transportation by propeller aircraft |
01/714406 DC : DRAFT OCT 2001 | ISO/DIS 16750-3 - ROAD VEHICLES - ENVIRONMENTAL CONDITIONS AND TESTING FOR ELECTRICAL AND ELECTRONIC EQUIPMENT - PART 3: MECHANICAL LOADS |
PD IEC/TS 62271-210:2013 | High-voltage switchgear and controlgear Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV |
BS ISO 19453-3:2018 | Road vehicles. Environmental conditions and testing for electrical and electronic equipment for drive system of electric propulsion vehicles Mechanical loads |
BS EN ISO 14903:2017 | Refrigerating systems and heat pumps. Qualification of tightness of components and joints |
BS EN 80601-2-30 : 2010 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS |
UNE-EN 60068-2-53:2011 | Environmental testing -- Part 2-53: Tests and guidance: Combined climatic (temperature/humidity) and dynamic (vibration/shock) tests |
OIML R 146-1 : 2016 | PROTEIN MEASURING INSTRUMENTS FOR CEREAL GRAIN AND OILSEEDS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
16/30316718 DC : 0 | BS EN ISO 80601-2-61 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-61: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT |
08/30181467 DC : DRAFT JULY 2008 | BS EN 15834 - REFRIGERATING SYSTEMS AND HEAT PUMPS - QUALIFICATION OF TIGHTNESS OF COMPONENTS AND JOINTS |
BS 7987(2001) : 2001 | ROAD TRAFFIC SIGNAL SYSTEMS |
BS EN 61643-11 : 2012 | LOW-VOLTAGE SURGE PROTECTIVE DEVICES - PART 11: SURGE PROTECTIVE DEVICES CONNECTED TO LOW-VOLTAGE POWER SYSTEMS - REQUIREMENTS AND TEST METHODS |
02/206181 DC : DRAFT MAY 2002 | IEC 61019-1. ED.1 - SURFACE ACOUSTIC WAVE RESONATORS (SAW) OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
PREN 50556 : DRAFT 2010 | ROAD TRAFFIC SIGNAL SYSTEMS |
03/111613 DC : DRAFT AUG 2003 | BS EN ISO 9919 - MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF PULSE OXIMETER EQUIPMENT FOR MEDICAL USE |
EN 62745:2017 | Safety of machinery - Requirements for cableless control systems of machinery |
IEC 62745:2017 | Safety of machinery - Requirements for cableless control systems of machinery |
16/30312315 DC : 0 | BS EN ISO 80601-2-55 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS |
BS EN 60068-2-81:2003 | Environmental testing. Test methods Test Ei. Shock. Shock response spectrum synthesis |
CSA Z18779 : 2008 | MEDICAL DEVICES FOR CONSERVING OXYGEN AND OXYGEN MIXTURES - PARTICULAR REQUIREMENTS |
03/113382 DC : DRAFT SEP 2003 | BS EN ISO 21649 - NEEDLE-FREE INJECTORS FOR MEDICAL USE - REQUIREMENTS AND TEST METHODS |
CAN/CSA-B354.6:17 | Mobile elevating work platforms — Design, calculations, safety requirements, and test methods (Adopted ISO 16368:2010, second edition , 2010-05-15, with Canadian deviations) |
OIML R 139-2 : 2014 | COMPRESSED GASEOUS FUEL MEASURING SYSTEMS FOR VEHICLES - PART 2: METROLOGICAL CONTROLS AND PERFORMANCE TESTS |
I.S. EN 62604-1:2015 | SURFACE ACOUSTIC WAVE (SAW) AND BULK ACOUSTIC WAVE (BAW) DUPLEXERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
OIML R 144-1 : 2013 | INSTRUMENTS FOR CONTINUOUS MEASUREMENT OF CO, NO[X] IN STATIONARY SOURCE EMISSIONS - PART 1: METROLOGICAL AND TECHNICAL REQUIREMENTS |
EN 60601-1-11:2015 | Medical electrical equipment - Part 1-11: General requirements for basic safety and essential performance - Collateral Standard: Requirements for medical electrical equipment and medical electrical systems used in the home healthcare environment |
I.S. EN 61753-101-2:2006 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS PERFORMANCE STANDARD - PART 101-2: FIBRE MANAGEMENT SYSTEMS FOR CATEGORY C - CONTROLLED ENVIRONMENT |
IEEE C62.35-2010 | IEEE Standard Test Methods for Avalanche Junction Semiconductor Surge-Protective Device Components |
I.S. EN ISO 80601-2-55:2018 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-55: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF RESPIRATORY GAS MONITORS (ISO 80601-2-55:2018) |
I.S. EN 60122-1:2002 AMD 1 2018 | QUARTZ CRYSTAL UNITS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
I.S. EN 60862-1:2015 | SURFACE ACOUSTIC WAVE (SAW) FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
I.S. EN ISO 14903:2017 | REFRIGERATING SYSTEMS AND HEAT PUMPS - QUALIFICATION OF TIGHTNESS OF COMPONENTS AND JOINTS (ISO 14903:2017) |
I.S. EN 45502-2-3:2010 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-3: PARTICULAR REQUIREMENTS FOR COCHLEAR AND AUDITORY BRAINSTEM IMPLANT SYSTEMS |
IEEE/ANSI N42.53-2013 | American National Standard Performance Criteria for Backpack-Based Radiation-Detection Systems Used for Homeland Security |
I.S. EN 62326-20:2016 | PRINTED BOARDS - PART 20: PRINTED CIRCUIT BOARDS FOR HIGHBRIGHTNESS LEDS |
NF EN 61373 : 2011 | RAILWAY APPLICATIONS - ROLLING STOCK EQUIPMENT - SHOCK AND VIBRATION TESTS |
UNE-EN 62660-2:2011 | Secondary lithium-ion cells for the propulsion of electric road vehicles - Part 2: Reliability and abuse testing |
CEI EN 60068-2-53 : 2011 | ENVIRONMENTAL TESTING - PART 2-53: TESTS AND GUIDANCE: COMBINED CLIMATIC (TEMPERATURE/HUMIDITY) AND DYNAMIC (VIBRATION/SHOCK) TESTS |
PREN ISO 15197 : DRAFT 2011 | IN VITRO DIAGNOSTIC TEST SYSTEMS - REQUIREMENTS FOR BLOOD-GLUCOSE MONITORING SYSTEMS FOR SELF-TESTING IN MANAGING DIABETES MELLITUS |
TS 105 175-1 : 2.0.0 | ACCESS, TERMINALS, TRANSMISSION AND MULTIPLEXING (ATTM); PLASTIC OPTICAL FIBRE SYSTEM SPECIFICATIONS FOR 100 MBIT/S AND 1 GBIT/S |
UNE-EN 62752:2017 | In-cable control and protection device for mode 2 charging of electric road vehicles (IC-CPD) |
UNE-EN 12966:2015 | Road vertical signs - Variable message traffic signs |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
I.S. EN 45502-2-1:2004 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-1: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT BRADYARRHYTHMIA (CARDIAC PACEMAKERS) |
I.S. EN 60068-2-53:2010 | ENVIRONMENTAL TESTING - PART 2-53: TESTS AND GUIDANCE: COMBINED CLIMATIC (TEMPERATURE/HUMIDITY) AND DYNAMIC (VIBRATION/SHOCK) TESTS |
I.S. EN ISO 20072:2013 | AEROSOL DRUG DELIVERY DEVICE DESIGN VERIFICATION - REQUIREMENTS AND TEST METHODS (ISO 20072:2009) |
DIN EN 13557:2009-07 | Cranes - Controls and control stations; German version EN 13557:2003+A2:2008 |
IEC 61810-7:2006 | Electromechanical elementary relays - Part 7: Test and measurement procedures |
IEC 61753-101-3:2006 | Fibre optic interconnecting devices and passive components performance standard - Part 101-3: Fibre management systems for Category U - Uncontrolled environment |
UNE-EN ISO 15197:2015 | In vitro diagnostic test systems - Requirements for blood-glucose monitoring systems for self-testing in managing diabetes mellitus (ISO 15197:2013) |
BS EN 13557 : 2003 | CRANES - CONTROLS AND CONTROL STATIONS |
IEC 62326-20:2016 | Printed boards - Part 20: Printed circuit boards for high-brightness LEDs |
UNE-EN 1808:2016 | Safety requirements for suspended access equipment - Design calculations, stability criteria, construction - Examinations and tests |
BS EN ISO 21647:2009 | Medical electrical equipment. Particular requirements for the basic safety and essential performance of respiratory gas monitors |
IEC 60068-2-53:2010 | Environmental testing - Part 2-53: Tests and guidance - Combined climatic (temperature/humidity) and dynamic (vibration/shock) tests |
BS EN ISO 18779:2005 | Medical devices for conserving oxygen and oxygen mixtures. Particular requirements |
13/30245874 DC : 0 | BS IEC 62694 ED 1.0 - RADIATION PROTECTION INSTRUMENTATION - BACKPACK-TYPE RADIATION DETECTOR (BRD) FOR DETECTION OF ILLICIT TRAFFICKING OF RADIOACTIVE MATERIAL |
IEC 62759-1:2015 | Photovoltaic (PV) modules - Transportation testing - Part 1: Transportation and shipping of module package units |
ISO 9919:2005 | Medical electrical equipment Particular requirements for the basic safety and essential performance of pulse oximeter equipment for medical use |
IEC 60068-2-55:2013 | Environmental testing - Part 2-55: Tests - Test Ee and guidance - Loose cargo testing including bounce |
DIN EN ISO 18779:2005-06 | Medical devices for conserving oxygen and oxygen mixtures - Particular requirements (ISO 18779:2005) |
EN 45502-1 : 2015 | IMPLANTS FOR SURGERY - ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 1: GENERAL REQUIREMENTS FOR SAFETY, MARKING AND FOR INFORMATION TO BE PROVIDED BY THE MANUFACTURER |
EN 12966:2014 | Road vertical signs - Variable message traffic signs |
EN 62759-1:2015 | Photovoltaic (PV) modules - Transportation testing - Part 1: Transportation and shipping of module package units |
EN 60068-2-57:2013 | Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method |
EN 80601-2-30:2010/A1:2015 | MEDICAL ELECTRICAL EQUIPMENT - PART 2-30: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF AUTOMATED NON-INVASIVE SPHYGMOMANOMETERS (IEC 80601-2-30:2009/A1:2013) |
EN 60068-2-6:2008 | Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal) |
EN 61753-101-2 : 2006 | FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS PERFORMANCE STANDARD - PART 101-2: FIBRE MANAGEMENT SYSTEMS FOR CATEGORY C - CONTROLLED ENVIRONMENT |
EN 60122-1:2002/A1:2018 | QUARTZ CRYSTAL UNITS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION (IEC 60122-1:2002/A1:2017) |
EN 45502-2-2 : 2008 COR 2009 | ACTIVE IMPLANTABLE MEDICAL DEVICES - PART 2-2: PARTICULAR REQUIREMENTS FOR ACTIVE IMPLANTABLE MEDICAL DEVICES INTENDED TO TREAT TACHYARRHYTHMIA (INCLUDES IMPLANTABLE DEFIBRILLATORS) |
EN 60068-2-55:2013 | Environmental testing - Part 2-55: Tests - Test Ee and guidance - Loose cargo testing including bounce |
EN 60068-2-80:2005 | Environmental testing - Part 2-80: Tests - Test Fi: Vibration - Mixed mode |
EN 12405-3:2015 | Gas meters - Conversion devices - Part 3: Flow computer |
EN 60368-1:2000/A1:2004 | PIEZOELECTRIC FILTERS OF ASSESSED QUALITY - PART 1: GENERIC SPECIFICATION |
EN 50512:2009 | Electrical installations for lighting and beaconing of aerodromes - Advanced Visual Docking Guidance Systems (A-VDGS) |
EN 62660-2:2011 | Secondary lithium-ion cells for the propulsion of electric road vehicles - Part 2: Reliability and abuse testing |
EN 61810-7:2006 | Electromechanical elementary relays - Part 7: Test and measurement procedures |
EN 62575-1:2016 | Radio frequency (RF) bulk acoustic wave (BAW) filters of assessed quality - Part 1: Generic specification |
EN 62326-20:2016 | Printed boards - Part 20: Printed circuit boards for high-brightness LEDs |
EN 50491-2 : 2010 AMD 1 2015 | GENERAL REQUIREMENTS FOR HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) AND BUILDING AUTOMATION AND CONTROL SYSTEMS (BACS) - PART 2: ENVIRONMENTAL CONDITIONS |
EN 60068-2-53:2010 | Environmental testing - Part 2-53: Tests and guidance: Combined climatic (temperature/humidity) and dynamic (vibration/shock) tests |
DIN EN 12966-1:2010-03 | ROAD VERTICAL SIGNS - VARIABLE MESSAGE TRAFFIC SIGNS - PART 1: PRODUCT STANDARD |
EN 50249:2002 | Electromagnetic locators for buried pipes and cables - Performance and safety |
CEN ISO/TS 14907-1:2015 | Electronic fee collection - Test procedures for user and fixed equipment - Part 1: Description of test procedures (ISO/TS 14907-1:2015) |
EN 60068-3-8:2003 | Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests |
UNI EN 1789 : 2014 | MEDICAL VEHICLES AND THEIR EQUIPMENT - ROAD AMBULANCES |
EN 62694:2016 | Radiation protection instrumentation - Backpack-type radiation detector (BRD) for the detection of illicit trafficking of radioactive material |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 61373:2010 | Railway applications - Rolling stock equipment - Shock and vibration tests |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
EN 300 019-2-3 : 2.4.1 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 2-3: SPECIFICATION OF ENVIRONMENTAL TESTS; STATIONARY USE AT WEATHERPROTECTED LOCATIONS |
IEC 60068-5-2:1990 | Environmental testing - Part 5-2: Guide to drafting of test methods - Terms and definitions |
MIL-STD-810 Revision G:2008 | ENVIRONMENTAL ENGINEERING CONSIDERATIONS AND LABORATORY TESTS |
ISO 2041:2009 | Mechanical vibration, shock and condition monitoring Vocabulary |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60068-3-8:2003 | Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
ENV 13005 : DRAFT 1999 | GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT |
IEC 60050-300:2001 | International Electrotechnical Vocabulary (IEV) - Part 300: Electrical and electronic measurements and measuring instruments - Part 311: General terms relating to measurements - Part 312: General terms relating to electrical measurements - Part 313: Types of electrical measuring instruments - Part 314: Specific terms according to the type of instrument |
EN 300 019-2-7 : 3.0.1 | ENVIRONMENTAL ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT; PART 2-7: SPECIFICATION OF ENVIRONMENTAL TESTS; PORTABLE AND NON-STATIONARY USE |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.