Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English - French
04-25-2013
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Test requirements and associated
parameters
5 Severities
6 Preconditioning
7 Initial measurements
8 Testing
9 Intermediate measurements
10 Recovery
11 Final measurements
12 Information to be given in the relevant
specification
13 Information to be given in the test report
Annex A (informative) - Guidance for time-history and
sine-beat methods
Bibliography
IEC 60068-2-57:2013 provides a standard procedure for determining, by the time-history and sine-beat methods, the ability of a specimen to withstand specified severities of transient vibration. This third edition cancels and replaces the second edition, published in 1999. It also replaces IEC 60068-2-59:1990, which will be withdrawn. This edition includes only minor technical changes with respect to the previous edition:
- editorially combines IEC 60068-2-57 and IEC 60068-2-59;
- the title has been modified to include a sine beat method.
This publication is to be read in conjunction with IEC 60068-1:1988.
DevelopmentNote |
Supersedes IEC 60068-2-59. To be read in conjunction with IEC 60068-1. Stability date: 2020. (04/2013)
|
DocumentType |
Standard
|
Pages |
82
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
JIS C 0057:2002 | Identical |
JIS C 60068-2-57:2018 | Identical |
NF EN 60068-2-57 : 2013 | Identical |
NEN EN IEC 60068-2-57 : 2013 | Identical |
PN EN 60068-2-57 : 2013 | Identical |
DIN EN 60068-2-57 : 2015 | Identical |
VDE 0468-2-57 : 2015 | Identical |
SAC GB/T 2423.48:2018 | Identical |
UNE-EN 60068-2-57:2001 | Identical |
BS EN 60068-2-57:2013 | Identical |
CEI EN 60068-2-57 : 2014 | Identical |
EN 60068-2-57:2013 | Identical |
BS 2011-2.1FF(1989) : 1990 AMD 7834 | Identical |
NFC 20 757 : 1990 | Identical |
DIN IEC 60068-2-57:1991-04 | Identical |
PNE-EN 60068-2-57:2000/FprA1 | Identical |
NEN 10068-2-57 : 1994 | Identical |
UNE-EN 60068-2-57:2013 | Identical |
SN EN 60068-2-57 : 2000 | Identical |
I.S. EN 62271-2:2003 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
CEI EN 60068-2-47 : 2006 | ENVIRONMENTAL TESTING - PART 2-47: TESTS - MOUNTING OF SPECIMENS FOR VIBRATION, IMPACT AND SIMILAR DYNAMIC TESTS |
02/210916 DC : DRAFT OCT 2002 | IEC 62271-002 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 002: SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
10/30181171 DC : 0 | BS EN 62586 - POWER QUALITY MONITORING DEVICES IN POWER SUPPLY SYSTEMS |
CEI EN 62271-207 : 2014 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
BS EN 60068-2-47:2005 | Environmental testing Tests. Mounting of specimens for vibration, impact and similar dynamic tests |
I.S. EN 62586-1:2017 | POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 1: POWER QUALITY INSTRUMENTS (PQI) |
I.S. EN 60068-2-81:2003 | ENVIRONMENTAL TESTING - PART 2-81: TESTS - TEST EI: SHOCK - SHOCK RESPONSE SPECTRUM SYNTHESIS |
EN 60068-2-81:2003 | Environmental testing - Part 2-81: Tests - Test Ei: Shock - Shock response spectrum synthesis |
EN 62586-1:2017 | Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI) |
EN 61587-2:2011 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 2: SEISMIC TESTS FOR CABINETS AND RACKS (IEC 61587-2:2011) |
EN 60068-2-47:2005 | Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests |
EN 60255-21-3:1995 | Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests |
PD IEC/TS 61463:2016 | Bushings. Seismic qualification |
BS 142-1.5.3(1993) : 1993 AMD 8833 | ELECTRICAL PROTECTION RELAYS - INFORMATION AND REQUIREMENTS FOR ALL PROTECTION RELAYS - VIBRATION, SHOCK, BUMP AND SEISMIC TESTING - SEISMIC TESTS |
05/30132701 DC : DRAFT APR 2005 | IEC 62271-300 ED 1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 300: SEISMIC QUALIFICATION OF ALTERNATING CURRENT CIRCUIT-BREAKERS |
CEI EN 61587-2 : 2012 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 2: SEISMIC TESTS FOR CABINETS AND RACKS |
18/30367515 DC : DRAFT APR 2018 | BS EN 60068-3-3 - ENVIRONMENTAL TESTING - PART 3-3: GUIDANCE - SEISMIC TEST METHODS FOR EQUIPMENTS |
BS EN 62586-1:2017 | Power quality measurement in power supply systems Power quality instruments (PQI) |
BS IEC/IEEE 60780-323 : 2016 | NUCLEAR FACILITIES - ELECTRICAL EQUIPMENT IMPORTANT TO SAFETY - QUALIFICATION |
BS EN 60068-2-81:2003 | Environmental testing. Test methods Test Ei. Shock. Shock response spectrum synthesis |
CEI EN 61587-5 : 2014 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 5: SEISMIC TESTS FOR CHASSIS, SUBRACKS AND PLUG-IN UNITS |
UNE-EN 62271-207:2012 | High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV |
BS EN 62271-207:2012 | High-voltage switchgear and controlgear Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV |
NF EN 62271-2 : 2004 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
BS IEC 60780:1998 | Nuclear power plants. Electrical equipment of the safety system. Qualification |
UNE-EN 62586-1:2014 | Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI) |
BS EN 62271-2:2003 | High-voltage switchgear and controlgear Seismic qualification for rated voltages of 72,5 kV and above |
09/30211740 DC : 0 | BS EN 62271-210 ED1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 210: SEISMIC QUALIFICATION FOR METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC TR 62271-300:2006 | High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers |
IEC/IEEE 60780-323:2016 | Nuclear facilities - Electrical equipment important to safety - Qualification |
I.S. EN 62271-207:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012 (EQV)) |
NF EN 300019 2-3 : 2016 | ENVIRONMENTAL ENGINEERING (EE) - ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - PART 2-3: SPECIFICATION OF ENVIRONMENTAL TESTS - STATIONARY USE AT WEATHERPROTECTED LOCATIONS (V2.4.1) |
IEC 60780:1998 | Nuclear power plants - Electrical equipment of the safety system - Qualification |
IEC TS 62271-210:2013 | High-voltage switchgear and controlgear - Part 210: Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV |
NF EN 300019 2-4 : 2016 | ENVIRONMENTAL ENGINEERING (EE) - ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - PART 2-4: SPECIFICATION OF ENVIRONMENTAL TESTS - STATIONARY USE AT NON-WEATHERPROTECTED LOCATIONS (V2.4.1) |
CEI 45-60 : 2009 | NUCLEAR POWER PLANTS - ELECTRICAL EQUIPMENT OF THE SAFETY SYSTEM - QUALIFICATION |
BS EN 60780-323:2017 | Nuclear facilities. Electrical equipment important to safety. Qualification |
BS EN 61587-5:2014 | Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 Seismic tests for chassis, subracks and plug-in units |
BS ISO 10813-1:2004 | Vibration generating machines. Guidance for selection Equipment for environmental testing |
02/708964 DC : DRAFT JULY 2002 | ISO/DIS 10813-1 - VIBRATION-GENERATING MACHINES - GUIDANCE FOR SELECTION - PART 1: EQUIPMENT FOR ENVIRONMENTAL TESTING |
05/30134423 DC : DRAFT JUN 2005 | IEC 62271-207 - HV SWITCHGEAR ASSEMBLIES - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
CEI EN 60255-21-3 : 1998 | ELECTRICAL RELAYS - PART 21: VIBRATION, SHOCK, BUMP AND SEISMIC TESTS ON MEASURING RELAYS AND PROTECTION EQUIPMENT - SECTION 3: SEISMIC TESTS |
IEC TS 61463:2016 | Bushings - Seismic qualification |
13/30264600 DC : 0 | BS EN 60747-14-8 ED 1.0 - SEMICONDUCTOR DEVICES - PART 14-8: SEMICONDUCTOR SENSORS - CAPACITIVE DEGRADATION SENSOR OF LIQUID |
BS 2011-4.3(1991) : 1991 AMD 7842 | ENVIRONMENTAL TESTING - MISCELLANEOUS - GUIDE TO SEISMIC TEST METHODS FOR EQUIPMENTS |
11/30249337 DC : 0 | BS EN 61587-5 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 5: SEISMIC TESTS FOR CHASSIS, SUBRACKS, AND ASSOCIATED PLUG-IN UNIT |
I.S. EN 61587-5:2014 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 5: SEISMIC TESTS FOR CHASSIS, SUBRACKS AND PLUG-IN UNITS |
15/30327720 DC : 0 | BS EN 62586-1 - POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 1: POWER QUALITY INSTRUMENTS (PQI) |
I.S. EN 60780-323:2017 | NUCLEAR FACILITIES - ELECTRICAL EQUIPMENT IMPORTANT TO SAFETY - QUALIFICATION |
ISO 10813-1:2004 | Vibration generating machines — Guidance for selection — Part 1: Equipment for environmental testing |
IEC 60255-21-3:1993 | Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests |
IEC 62586-1:2017 | Power quality measurement in power supply systems - Part 1: Power quality instruments (PQI) |
I.S. EN 60068-2-47:2005 | ENVIRONMENTAL TESTING - PART 2-47: TESTS - MOUNTING OF SPECIMENS FOR VIBRATION, IMPACT AND SIMILAR DYNAMIC TESTS |
IEC 60068-2-81:2003 | Environmental testing - Part 2-81: Tests - Test Ei: Shock - Shock response spectrum synthesis |
IEC 61166:1993 | High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers |
IEC 61747-1:1998+AMD1:2003 CSV | Liquid crystal and solid-state display devices - Part 1: Generic specification |
IEC 61587-5:2013 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 5: Seismic tests for chassis, subracks and plug-in units |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 61587-2:2011 | Mechanical structures for electronic equipment - Tests for IEC 60917 and 60297 - Part 2: Seismic tests for cabinets and racks |
IEC 62271-2:2003 | High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above |
12/30255394 DC : DRAFT APR 2012 | BS EN 62586-1 - POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - POWER QUALITY INSTRUMENTS (PQI) |
EN 60780-323:2017 | Nuclear facilities - Electrical equipment important to safety - Qualification |
NF EN 60255 21-3 : 1998 | ELECTRICAL RELAYS - PART 21: VIBRATION, SHOCK, BUMP AND SEISMIC TESTS ON MEASURING RELAYS AND PROTECTION EQUIPMENT - SECTION 3: SEISMIC TESTS |
CEI EN 62586-1 : 2016 | POWER QUALITY MEASUREMENT IN POWER SUPPLY SYSTEMS - PART 1: POWER QUALITY INSTRUMENTS (PQI) |
13/30264596 DC : 0 | BS EN 60747-14-7 ED 1.0 - SEMICONDUCTOR DEVICES - PART 14-7: SEMICONDUCTOR SENSORS - FLOW METER |
10/30232728 DC : 0 | BS EN 62271-207 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
PD IEC/TS 62271-210:2013 | High-voltage switchgear and controlgear Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV |
I.S. EN 61587-2:2011 | MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 2: SEISMIC TESTS FOR CABINETS AND RACKS (IEC 61587-2:2011) |
BS EN 61587-2:2011 | Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 Seismic tests for cabinets and racks |
IEEE C62.35-2010 | IEEE Standard Test Methods for Avalanche Junction Semiconductor Surge-Protective Device Components |
I.S. EN 60255-21-3:1997 | ELECTRICAL RELAYS - PART 21: VIBRATION, SHOCK, BUMP AND SEISMIC TESTS ON MEASURING RELAYS AND PROTECTION EQUIPMENT - SECTION 3: SEISMIC TESTS |
IEC 60300-3-5:2001 | Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles |
IEC 62271-207:2012 | High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV |
EN 62271-207:2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012) |
EN 62271-2:2003 | High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above |
EN 61587-5:2014 | Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 5: Seismic tests for chassis, subracks and plug-in units |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 60068-2-81:2003 | Environmental testing - Part 2-81: Tests - Test Ei: Shock - Shock response spectrum synthesis |
IEC 60068-2-64:2008 | Environmental testing - Part 2-64: Tests - Test Fh: Vibration, broadband random and guidance |
IEC 60068-3-3:1991 | Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments |
ISO 2041:2009 | Mechanical vibration, shock and condition monitoring Vocabulary |
IEC 60068-2-47:2005 | Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests |
IEC 60068-3-8:2003 | Environmental testing - Part 3-8: Supporting documentation and guidance - Selecting amongst vibration tests |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.