IEC 60044-8:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Instrument transformers - Part 8: Electronic current transformers
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
04-27-2016
English, Spanish, Castilian
07-19-2002
FOREWORD
1 Scope
1.1 General
1.2 General block diagram of electronic current transformers
1.3 General block diagram of electronic transformers with a
digital output
2 Normative references
3 Definitions
3.1 General definitions
3.2 Additional definitions for measuring electronic current
transformers
3.3 Additional definitions for protective electronic current
transformers
3.4 Additional definitions for digital output
3.5 Additional definitions for analogue voltage output
3.6 Index of main definitions and abbreviations
4 Normal and special service conditions
4.1 General
4.2 Normal service conditions
4.3 Special service conditions
4.4 System earthing
5 Ratings
5.1 General ratings
5.2 Standard values for rated phase offset
5.3 Rating for digital output
5.4 Rating for analogue voltage output
6 Design requirements
6.1 General design requirements
6.2 Design requirements for digital output
6.3 Design requirements for analogue voltage output
7 Classification of tests
7.1 General
7.2 Type tests
7.3 Routine tests
7.4 Special tests
8 Type test
8.1 Short-time current tests
8.2 Temperature-rise test
8.3 Impulse tests on primary terminals
8.4 Wet test for outdoor type electronic current transformers
8.5 RIV tests
8.6 Transmitted overvoltage test
8.7 Low-voltage components voltage withstand test
8.8 EMC tests
8.9 Accuracy test
8.10 Additional accuracy tests for protective electronic current
transformers
8.11 Verification of the protection
8.12 Tightness tests
8.13 Vibration tests
8.14 Additional type test for digital output
9 Routine tests
9.1 Verification of terminal markings
9.2 Power-frequency withstand tests on primary terminals
and partial discharge measurement
9.3 Power-frequency voltage withstand test for low-voltage
components
9.4 Accuracy tests
9.5 Tightness tests
9.6 Additional routine tests for digital output
9.7 Additional routine tests for analogue output
10 Special tests
10.1 Chopped lightning-impulse test on primary terminals
10.2 Measurement of capacitance and dielectric dissipation
factor
10.3 Mechanical tests
10.4 Tests for accuracy versus harmonics
10.5 Tests in accordance with the technology applied
11 Marking
11.1 Terminal marking - General rules
11.2 Rating plate markings
12 Additional requirements for measuring electronic current
transformers
12.1 Accuracy class designation
12.2 Limits of current error and phase error at rated frequency
12.3 Accuracy requirements on harmonics
13 Additional requirements for protective electronic current
transformers
13.1 Accuracy classes
13.2 Accuracy requirements on harmonics
14 Information to be given with enquiries, tenders and orders
14.1 Designation
14.2 Dependability
15 Rules for transport, storage and installation
15.1 Conditions during transport, storage and installation
15.2 Installation
15.3 Unpacking and lifting
15.4 Assembly
15.5 Operation
15.6 Maintenance
16 Safety
16.1 Electrical aspects
16.2 Mechanical aspects
16.3 Thermal aspects
Annex A (informative) Transient performances of ECTs
Annex B (informative) Technical information for electronic
current transformers with digital output
Annex C (informative) Technical information for electronic
current transformers with analogue output
Annex D (normative) Frequency response and accuracy requirements
on harmonics for electronic current and voltage transformer
Annex E (informative) Graph explaining the accuracy requirements
Bibliography
Figures
Tables
This part of IEC 60044 applies to newly manufactured electronic current transformers having an analogue voltage output or a digital output, for use with electrical measuring instruments and electrical protective devices at nominal frequencies from 15 Hz to 100 Hz.
Committee |
TC 38
|
DevelopmentNote |
Stability Date: 2016. (10/2012)
|
DocumentType |
Standard
|
Pages |
124
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
GOST R IEC 60044-8 : 2010 | Identical |
NEN EN IEC 60044-8 : 2003 | Identical |
I.S. EN 60044-8:2002 | Identical |
PN EN 60044-8 : 2006 | Identical |
VDE 0414-44-8 : 2003 | Identical |
UNE-EN 60044-8:2005 | Identical |
BS EN 60044-8:2002 | Identical |
CEI EN 60044-8 : 2004 | Identical |
EN 60044-8:2002 | Identical |
DIN EN 60044-8 : 2003 | Identical |
UNE-EN 62271-205:2011 | High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV |
BS EN 60255-1:2010 | Measuring relays and protection equipment Common requirements |
I.S. EN 50463-2:2017 | RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING |
17/30326671 DC : 0 | BS ISO 27919-1 - CARBON DIOXIDE CAPTURE - PART 1: PERFORMANCE EVALUATION METHODS FOR POST-COMBUSTION CO[2] CAPTURE INTEGRATED WITH A POWER PLANT |
PREN 50463-2 : DRAFT 2015 | RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING |
BS EN 50463-2:2017 | Railway applications. Energy measurement on board trains Energy measuring |
15/30329546 DC : 0 | BS EN 50463-2 - RAILWAY APPLICATIONS - ENERGY MEASUREMENT ON BOARD TRAINS - PART 2: ENERGY MEASURING |
03/113813 DC : 0 | IEC 60034-2. ED.4 - ROTATING ELECTRICAL MACHINES - PART 2: METHODS FOR DETERMINING LOSSES AND EFFICIENCY FROM TESTS (EXCLUDING MACHINES FOR TRACTION VEHICLES) |
IEEE C37.241-2017 | IEEE Guide for Application of Optical Instrument Transformers for Protective Relaying |
I.S. EN 61869-6:2016 | INSTRUMENT TRANSFORMERS - PART 6: ADDITIONAL GENERAL REQUIREMENTS FOR LOW-POWER INSTRUMENT TRANSFORMERS |
NF EN 62271-205 : 2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
EN 62271-205:2008/corrigendum:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
EN 61869-6:2016 | Instrument transformers - Part 6: Additional general requirements for low-power instrument transformers |
EN 61850-9-1:2003 | Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link |
EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
MIL-DTL-32483 Base Document:2013 | Switchgear, Power, Hard-Mounted, Medium Voltage, Naval Shipboard |
MIL-DTL-917 Revision F:2014 | ELECTRIC POWER EQUIPMENT, BASIC REQUIREMENTS FOR |
14/30284930 DC : 0 | BS EN 62689-2 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: GENERAL PRINCIPLES AND REQUIREMENTS |
11/30241212 DC : DRAFT JAN 2011 | BS EN 60688 - ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS |
UNE-EN 61557-12:2010 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -- Part 12: Performance measuring and monitoring devices (PMD) |
IEC TS 61850-2:2003 | Communication networks and systems in substations - Part 2: Glossary |
IEEE C57.13.1-2006 REDLINE | IEEE Guide for Field Testing of Relaying Current Transformers |
IEC 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
BS EN 61869-6:2016 | Instrument transformers Additional general requirements for low-power instrument transformers |
I.S. EN 60143-2:2013 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS (IEC 60143-2:2012 (EQV)) |
PD IEC/TR 61850-90-4:2013 | Communication networks and systems for power utility automation Network engineering guidelines |
DD IEC/TS 61850-2:2003 | Communication networks and systems in substations Glossary |
BS EN 50327:2003 | Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups |
BS EN 62689-2:2017 | Current and voltage sensors or detectors, to be used for fault passage indication purposes System aspects |
CEI EN 61850-9-1 : 2015 | COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SYSTEM MAPPINGS (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK |
BS EN 60143-2:2013 | Series capacitors for power systems Protective equipment for series capacitor banks |
EN 50463-2:2017 | Railway applications - Energy measurement on board trains - Part 2: Energy measuring |
CEI EN 60143-2 : 2014 | SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENT FOR SERIES CAPACITOR BANKS |
I.S. EN 61557-12:2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD) |
I.S. EN 62271-205:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
IEC 61869-9:2016 | Instrument transformers - Part 9: Digital interface for instrument transformers |
BS EN 61850-9-1:2003 | Communication networks and systems in substations. Specific communication service mapping (SCSM) Sampled values over serial unidirectional multidrop point to point link |
EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
BS EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
BS EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements |
IEC 61557-12:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) |
I.S. EN 61850-9-1:2003 | COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SERVICE MAPPING (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK |
I.S. EN 62689-2:2017 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: SYSTEM ASPECTS |
IEEE C37.233 : 2009 | GUIDE FOR POWER SYSTEM PROTECTION TESTING |
IEEE DRAFT C57.13-1 : D8.0 2006 | FIELD TESTING OF RELAYING CURRENT TRANSFORMERS |
I.S. EN 62689-1:2016 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
CEI EN 60255-1 : 2011 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
CEI EN 61557-12 : 2013 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD) |
IEC 62689-2:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects |
CEI EN 62271-205 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
IEC 60255-1:1967 | Electrical relays - Part 1: Instantaneous all-or-nothing relays |
IEC 60688:2012 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
UNE-EN 60255-1:2010 | Measuring relays and protection equipment -- Part 1: Common requirements |
IEC 61850-9-1:2003 | Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link |
IEC 60143-2:2012 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
IEC TR 61869-103:2012 | Instrument transformers - The use of instrument transformers for power quality measurement |
IEC 62271-205:2008 | High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV |
UNE-EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
15/30328086 DC | BS EN 61557-12. Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Part 12. Power metering and monitoring devices (PMD) |
BS EN 61557-12:2008 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Performance measuring and monitoring devices (PMD) |
11/30245197 DC : 0 | BS EN 60143-2 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 2: PROTECTIVE EQUIPMENTS FOR SERIES CAPACITOR BANKS |
EN 62689-2:2017 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects |
12/30268049 DC : 0 | BS EN 62689-1 - CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
BS EN 62271-205:2008 | High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV |
14/30300261 DC : 0 | BS EN 62689-1 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: SYSTEM ASPECTS |
I.S. EN 60688:2013 | ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. AND D.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS (IEC 60688:2012 (EQV)) |
NF EN 60255-1 : 2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
I.S. EN 60255-1:2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
IEC 62888-2:2018 | Railway applications - Energy measurement on board trains - Part 2: Energy measurement |
IEC 61972:2002 | Method for determining losses and efficiency of three-phase cage induction motors |
EN 50327 : 2003 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
EN 61557-12:2008 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) |
EN 60255-1:2010 | Measuring relays and protection equipment - Part 1: Common requirements |
EN 60143-2:2013 | Series capacitors for power systems - Part 2: Protective equipment for series capacitor banks |
IEC 61025:2006 | Fault tree analysis (FTA) |
IEC 60480:2004 | Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use |
IEC 60874-10:1992 | Connectors for optical fibres and cables - Part 10: Sectional specification - Fibre optic connector type BFOC/2,5 |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
EN 50160 : 2010 AMD 1 2015 | VOLTAGE CHARACTERISTICS OF ELECTRICITY SUPPLIED BY PUBLIC ELECTRICITY NETWORKS |
IEC 60038:2009 | IEC standard voltages |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 60044-7:1999 | Instrument transformers - Part 7: Electronic voltage transformers |
IEC 60028:1925 | International standard of resistance for copper |
IEC 61850-9-1:2003 | Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60812:2006 | Analysis techniques for system reliability - Procedure for failure mode and effects analysis (FMEA) |
IEC TS 61462:1998 | Composite insulators - Hollow insulators for use in outdoor and indoor electrical equipment - Definitions, test methods, acceptance criteria and design recommendations |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
IEC 60304:1982 | Standard colours for insulation for low-frequency cables and wires |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 60255-24:2013 | Measuring relays and protection equipment - Part 24: Common format for transient data exchange (COMTRADE) for power systems |
IEC 60599:2015 | Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
IEC 60056:1987 | High-voltage alternating-current circuit-breakers |
IEC 60376:2005 | Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment |
IEC 60567:2011 | Oil-filled electrical equipment - Sampling of gases and analysis of free and dissolved gases - Guidance |
IEC 61166:1993 | High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
IEC 60085:2007 | Electrical insulation - Thermal evaluation and designation |
IEC 60296:2012 RLV | Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear |
IEC 60721-2-2:2012 | Classification of environmental conditions - Part 2-2: Environmental conditions appearing in nature - Precipitation and wind |
IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
IEC 60044-6:1992 | Instrument transformers - Part 6: Requirements for protective current transformers for transient performance |
IEC 60437:1997 | Radio interference test on high-voltage insulators |
IEC 60121:1960 | Recommendation for commercial annealed aluminium electrical conductor wire |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60044-1:1996+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 1: Current transformers |
IEC 60068-2-17:1994 | Basic environmental testing procedures - Part 2-17: Tests - Test Q: Sealing |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60376B:1974 | Second supplement: Clause 26 |
IEC 60255-5:2000 | Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
IEC 61850-7-4:2010 | Communication networks and systems for power utility automation - Part 7-4: Basic communication structure - Compatible logical node classes and data object classes |
IEC 60050-321:1986 | International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers |
IEC 60071-2:1996 | Insulation co-ordination - Part 2: Application guide |
IEC 61000-4-7:2002+AMD1:2008 CSV | Electromagnetic compatibility (EMC) - Part 4-7: Testing and measurement techniques - General guide on harmonics and interharmonics measurements and instrumentation, for power supply systems and equipment connected thereto |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60721-2-4:1987+AMD1:1988 CSV | Classification of environmental conditions - Part 2-4: Environmental conditions appearing in nature - Solar radiation and temperature |
TIA 485 : A1998(R2012) | ELECTRICAL CHARACTERISTICS OF GENERATORS AND RECEIVERS FOR USE IN BALANCED DIGITAL MULTIPOINT SYSTEMS |
IEC 60870-5-1:1990 | Telecontrol equipment and systems. Part 5: Transmission protocols - Section One: Transmission frame formats |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 61754-15:2009 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 15: Type LSH connector family |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
IEC 61000-4-29:2000 | Electromagnetic compatibility (EMC) - Part 4-29: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations on d.c. input power port immunity tests |
IEC 61754-1:2013 | Fibre optic interconnecting devices and passive components - Fibre optic connector interfaces - Part 1: General and guidance |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV | Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests |
IEC 61850-3:2013 | Communication networks and systems for power utility automation - Part 3: General requirements |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.