IEC 60044-7:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Instrument transformers - Part 7: Electronic voltage transformers
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
04-27-2016
English - French, English, French, Spanish, Castilian
12-17-1999
FOREWORD
1 General
1.1 Scope
1.2 Normative references
1.3 General block diagram of electronic
voltage transformers
2 Definitions
2.1 General definitions
2.2 Additional definitions for single-phase
electronic protective voltage transformers
2.3 Index of symbols
3 General requirements
3.1 General
3.2 Information to be given for enquiries, tenders
and orders
4 Normal and special service conditions
4.1 Normal service conditions
4.2 Special service conditions
4.3 Earthing system
5 Ratings
5.1 Standard values of rated voltages
5.2 Standard values of rated output
5.3 Standard values of rated voltage factor
5.4 Standard values of rated auxiliary power
supply voltage
5.5 Standard reference values of other influencing
parameters
6 Design requirements
6.1 Insulation requirements for primary voltage
sensor
6.2 Insulation requirements for low-voltage
components
6.3 Short-circuit withstand capability
6.4 Limits of temperature rise
6.5 Radio interference voltage requirements
6.6 Transmitted overvoltage requirements
6.7 Electromagnetic compatibility requirements
6.8 Reliability
6.9 Abnormal conditions withstand capability
6.10 Abnormal conditions signalling
6.11 Mechanical requirements
6.12 Earthing terminals
7 Classification of tests
7.1 Type tests
7.2 Routine tests
7.3 Special tests
8 Type tests
8.1 Impulse test on primary voltage terminals
8.2 Wet test for outdoor type electronic voltage
transformers
8.3 Tests for accuracy
8.4 Test for abnormal conditions withstand capacity
8.5 Radio interference voltage test
8.6 Transmitted overvoltage test
8.7 Electromagnetic compatibility tests
8.8 Impulse voltage withstand test for low-voltage
components
8.9 Transient performance tests
9 Routine tests
9.1 Verification of terminal markings
9.2 Power-frequency withstand tests on primary
voltage terminals and partial discharge
measurement
9.3 Power-frequency voltage withstand test for
low-voltage components
9.4 Tests for accuracy
10 Special tests
10.1 Chopped lightning-impulse test on primary
voltage terminals
10.2 Measurement of capacitance and dielectric
dissipation factor
10.3 Mechanical strength tests
11 Markings
11.1 Rating plate markings
11.2 Terminal markings
12 Accuracy requirements for single-phase electronic
measuring voltage transformers
12.1 General requirements
12.2 Maintenance requirements
12.3 Accuracy class designation for electronic
measuring voltage transformers
12.4 Standard accuracy classes for electronic
measuring voltage transformers
12.5 Limits of voltage error and phase displacement
for electronic measuring voltage transformers
13 Additional requirements for single-phase electronic
protective voltage transformers
13.1 General requirements
13.2 Maintenance requirements
13.3 Accuracy class designation for electronic
protective voltage transformers
13.4 Standard accuracy classes for electronic
protective voltage transformers
13.5 Limits of voltage error and phase displacement
for electronic protective voltage transformers
13.6 Transient performance requirements
Annex A (normative) Burdens for the transient response
test
Annex B (informative) Technical information for electronic
voltage transformers
Annex C (informative) Bibliography
Applies to newly manufactured electronic voltage transformers with analogue output, for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. The standard covers optical arrangements with electronic components. Three-phase voltage transformers are not included, but some of the requirements apply.
DevelopmentNote |
Also numbered as BS EN 60044-7. (09/2005) Stability Date: 2016. (10/2012)
|
DocumentType |
Standard
|
Pages |
137
|
PublisherName |
International Electrotechnical Committee
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
GOST R IEC 60044-7 : 2010 | Identical |
NF EN 60044-7 : 2001 | Identical |
NEN EN IEC 60044-7 : 2000 | Identical |
I.S. EN 60044-7:2000 | Identical |
SN EN 60044-7 : 2000 | Identical |
VDE 0414-44-7 : 2000 | Identical |
DIN EN 60044-7 : 2000 | Identical |
UNE-EN 60044-7:2001 | Identical |
CEI EN 60044-7 : 2001 | Identical |
EN 60044-7:2000 | Identical |
UNE-EN 62271-205:2011 | High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV |
BS EN 60255-1:2010 | Measuring relays and protection equipment Common requirements |
17/30326671 DC : 0 | BS ISO 27919-1 - CARBON DIOXIDE CAPTURE - PART 1: PERFORMANCE EVALUATION METHODS FOR POST-COMBUSTION CO[2] CAPTURE INTEGRATED WITH A POWER PLANT |
03/113813 DC : 0 | IEC 60034-2. ED.4 - ROTATING ELECTRICAL MACHINES - PART 2: METHODS FOR DETERMINING LOSSES AND EFFICIENCY FROM TESTS (EXCLUDING MACHINES FOR TRACTION VEHICLES) |
I.S. EN 60044-8:2002 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
CSA C60044-8 : 2007 : R2016 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
IEEE C37.241-2017 | IEEE Guide for Application of Optical Instrument Transformers for Protective Relaying |
I.S. EN 61869-6:2016 | INSTRUMENT TRANSFORMERS - PART 6: ADDITIONAL GENERAL REQUIREMENTS FOR LOW-POWER INSTRUMENT TRANSFORMERS |
NF EN 62271-205 : 2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
EN 62271-205:2008/corrigendum:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
EN 61869-6:2016 | Instrument transformers - Part 6: Additional general requirements for low-power instrument transformers |
EN 61850-9-1:2003 | Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link |
EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
14/30284930 DC : 0 | BS EN 62689-2 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: GENERAL PRINCIPLES AND REQUIREMENTS |
11/30241212 DC : DRAFT JAN 2011 | BS EN 60688 - ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS |
UNE-EN 61557-12:2010 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -- Part 12: Performance measuring and monitoring devices (PMD) |
IEC TS 61850-2:2003 | Communication networks and systems in substations - Part 2: Glossary |
CSA C60044-8 : 2007 : R2011 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
BS EN 60044-8:2002 | Instrument transformers Electronic current transformers |
S.R. CLC/TS 50549-2:2015 | REQUIREMENTS FOR GENERATING PLANTS TO BE CONNECTED IN PARALLEL WITH DISTRIBUTION NETWORKS - PART 2: CONNECTION TO A MV DISTRIBUTION NETWORK |
IEC 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
BS EN 61869-6:2016 | Instrument transformers Additional general requirements for low-power instrument transformers |
DD IEC/TS 61850-2:2003 | Communication networks and systems in substations Glossary |
BS EN 50327:2003 | Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups |
BS EN 62689-2:2017 | Current and voltage sensors or detectors, to be used for fault passage indication purposes System aspects |
CEI EN 61850-9-1 : 2015 | COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SYSTEM MAPPINGS (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK |
NF EN 60044-8 : 2006 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSDUCERS |
CSA C60044-8 :2007 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS |
I.S. EN 61557-12:2008 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD) |
I.S. EN 62271-205:2008 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
IEC 61869-9:2016 | Instrument transformers - Part 9: Digital interface for instrument transformers |
IEC 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
CEI EN 60044-8 : 2004 | INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS |
BS EN 61850-9-1:2003 | Communication networks and systems in substations. Specific communication service mapping (SCSM) Sampled values over serial unidirectional multidrop point to point link |
EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements |
BS EN 62689-1:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements |
BS EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
IEC 61557-12:2007 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) |
CLC/TS 50549-2:2015 | Requirements for generating plants to be connected in parallel with distribution networks - Part 2: Connection to a MV distribution network |
I.S. EN 61850-9-1:2003 | COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SERVICE MAPPING (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK |
I.S. EN 62689-2:2017 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: SYSTEM ASPECTS |
IEEE C37.233 : 2009 | GUIDE FOR POWER SYSTEM PROTECTION TESTING |
I.S. EN 62689-1:2016 | CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
CEI EN 60255-1 : 2011 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
CEI EN 61557-12 : 2013 | ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD) |
IEC 62689-2:2016 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects |
CEI EN 62271-205 : 2012 | HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV |
IEC 60255-1:1967 | Electrical relays - Part 1: Instantaneous all-or-nothing relays |
IEC 60688:2012 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
UNE-EN 60255-1:2010 | Measuring relays and protection equipment -- Part 1: Common requirements |
IEC 61850-9-1:2003 | Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link |
IEC TR 61869-103:2012 | Instrument transformers - The use of instrument transformers for power quality measurement |
IEC 62271-205:2008 | High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV |
UNE-EN 60688:2013 | Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals |
15/30328086 DC | BS EN 61557-12. Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Part 12. Power metering and monitoring devices (PMD) |
10/30215568 DC : 0 | BS EN 60255-121 - MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 121: FUNCTIONAL REQUIREMENTS FOR DISTANCE PROTECTION |
BS EN 61557-12:2008 | Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Performance measuring and monitoring devices (PMD) |
EN 62689-2:2017 | Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects |
12/30268049 DC : 0 | BS EN 62689-1 - CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS |
BS EN 62271-205:2008 | High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV |
14/30300261 DC : 0 | BS EN 62689-1 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: SYSTEM ASPECTS |
I.S. EN 60688:2013 | ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. AND D.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS (IEC 60688:2012 (EQV)) |
NF EN 60255-1 : 2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
I.S. EN 60255-1:2010 | MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS |
IEC 61972:2002 | Method for determining losses and efficiency of three-phase cage induction motors |
EN 50327 : 2003 AMD 1 2005 | RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS |
EN 61557-12:2008 | Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD) |
EN 60255-1:2010 | Measuring relays and protection equipment - Part 1: Common requirements |
EN 60044-8:2002 | Instrument transformers - Part 8: Electronic current transformers |
IEC 60255-22-1:2007 | Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests |
IEC 60038:2009 | IEC standard voltages |
IEC 60270:2000+AMD1:2015 CSV | High-voltage test techniques - Partial discharge measurements |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 60050-601:1985 | International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV | Instrument transformers - Part 2 : Inductive voltage transformers |
IEC 61000-4-8:2009 | Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60255-11:2008 | Measuring relays and protection equipment - Part 11: Voltage dips, short interruptions, variations and ripple on auxiliary power supply port |
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV | Common specifications for high-voltage switchgear and controlgear standards |
EN 50081-2:1993 | Electromagnetic compatibility - Generic emission standard - Part 2: Industrial environment |
IEC 60617-1:1985 | Graphical symbols for diagrams. Part 1: General information, general index. Cross-reference tables |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 60255-5:2000 | Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests |
IEC 60255-6:1988 | Electrical relays - Part 6: Measuring relays and protection equipment |
IEC 60050-321:1986 | International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers |
CISPR 11:2015 RLV | Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement |
IEC 60186:1987 | Voltage transformers |
IEC 60060-1:2010 | High-voltage test techniques - Part 1: General definitions and test requirements |
IEC 60071-1:2006+AMD1:2010 CSV | Insulation co-ordination - Part 1: Definitions, principles and rules |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-