• There are no items in your cart

IEC 60044-7:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Instrument transformers - Part 7: Electronic voltage transformers

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

04-27-2016

Superseded by

IEC 61869-6:2016

Language(s)

English - French, English, French, Spanish, Castilian

Published date

12-17-1999

US$400.00
Excluding Tax where applicable

FOREWORD
1 General
    1.1 Scope
    1.2 Normative references
    1.3 General block diagram of electronic
          voltage transformers
2 Definitions
    2.1 General definitions
    2.2 Additional definitions for single-phase
          electronic protective voltage transformers
    2.3 Index of symbols
3 General requirements
    3.1 General
    3.2 Information to be given for enquiries, tenders
          and orders
4 Normal and special service conditions
    4.1 Normal service conditions
    4.2 Special service conditions
    4.3 Earthing system
5 Ratings
    5.1 Standard values of rated voltages
    5.2 Standard values of rated output
    5.3 Standard values of rated voltage factor
    5.4 Standard values of rated auxiliary power
          supply voltage
    5.5 Standard reference values of other influencing
          parameters
6 Design requirements
    6.1 Insulation requirements for primary voltage
          sensor
    6.2 Insulation requirements for low-voltage
          components
    6.3 Short-circuit withstand capability
    6.4 Limits of temperature rise
    6.5 Radio interference voltage requirements
    6.6 Transmitted overvoltage requirements
    6.7 Electromagnetic compatibility requirements
    6.8 Reliability
    6.9 Abnormal conditions withstand capability
    6.10 Abnormal conditions signalling
    6.11 Mechanical requirements
    6.12 Earthing terminals
7 Classification of tests
    7.1 Type tests
    7.2 Routine tests
    7.3 Special tests
8 Type tests
    8.1 Impulse test on primary voltage terminals
    8.2 Wet test for outdoor type electronic voltage
          transformers
    8.3 Tests for accuracy
    8.4 Test for abnormal conditions withstand capacity
    8.5 Radio interference voltage test
    8.6 Transmitted overvoltage test
    8.7 Electromagnetic compatibility tests
    8.8 Impulse voltage withstand test for low-voltage
          components
    8.9 Transient performance tests
9 Routine tests
    9.1 Verification of terminal markings
    9.2 Power-frequency withstand tests on primary
          voltage terminals and partial discharge
          measurement
    9.3 Power-frequency voltage withstand test for
          low-voltage components
    9.4 Tests for accuracy
10 Special tests
    10.1 Chopped lightning-impulse test on primary
          voltage terminals
    10.2 Measurement of capacitance and dielectric
          dissipation factor
    10.3 Mechanical strength tests
11 Markings
    11.1 Rating plate markings
    11.2 Terminal markings
12 Accuracy requirements for single-phase electronic
    measuring voltage transformers
    12.1 General requirements
    12.2 Maintenance requirements
    12.3 Accuracy class designation for electronic
          measuring voltage transformers
    12.4 Standard accuracy classes for electronic
          measuring voltage transformers
    12.5 Limits of voltage error and phase displacement
          for electronic measuring voltage transformers
13 Additional requirements for single-phase electronic
    protective voltage transformers
    13.1 General requirements
    13.2 Maintenance requirements
    13.3 Accuracy class designation for electronic
          protective voltage transformers
    13.4 Standard accuracy classes for electronic
          protective voltage transformers
    13.5 Limits of voltage error and phase displacement
          for electronic protective voltage transformers
    13.6 Transient performance requirements
Annex A (normative) Burdens for the transient response
test
Annex B (informative) Technical information for electronic
voltage transformers
Annex C (informative) Bibliography

Applies to newly manufactured electronic voltage transformers with analogue output, for use with electrical measuring instruments and electrical protective devices at frequencies from 15 Hz to 100 Hz. The standard covers optical arrangements with electronic components. Three-phase voltage transformers are not included, but some of the requirements apply.

DevelopmentNote
Also numbered as BS EN 60044-7. (09/2005) Stability Date: 2016. (10/2012)
DocumentType
Standard
Pages
137
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

UNE-EN 62271-205:2011 High-voltage switchgear and controlgear -- Part 205: Compact switchgear assemblies for operation at rated voltages above 52 kV
BS EN 60255-1:2010 Measuring relays and protection equipment Common requirements
17/30326671 DC : 0 BS ISO 27919-1 - CARBON DIOXIDE CAPTURE - PART 1: PERFORMANCE EVALUATION METHODS FOR POST-COMBUSTION CO[2] CAPTURE INTEGRATED WITH A POWER PLANT
03/113813 DC : 0 IEC 60034-2. ED.4 - ROTATING ELECTRICAL MACHINES - PART 2: METHODS FOR DETERMINING LOSSES AND EFFICIENCY FROM TESTS (EXCLUDING MACHINES FOR TRACTION VEHICLES)
I.S. EN 60044-8:2002 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS
CSA C60044-8 : 2007 : R2016 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS
IEEE C37.241-2017 IEEE Guide for Application of Optical Instrument Transformers for Protective Relaying
I.S. EN 61869-6:2016 INSTRUMENT TRANSFORMERS - PART 6: ADDITIONAL GENERAL REQUIREMENTS FOR LOW-POWER INSTRUMENT TRANSFORMERS
NF EN 62271-205 : 2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
EN 62271-205:2008/corrigendum:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
EN 61869-6:2016 Instrument transformers - Part 6: Additional general requirements for low-power instrument transformers
EN 61850-9-1:2003 Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
EN 60688:2013 Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals
14/30284930 DC : 0 BS EN 62689-2 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: GENERAL PRINCIPLES AND REQUIREMENTS
11/30241212 DC : DRAFT JAN 2011 BS EN 60688 - ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS
UNE-EN 61557-12:2010 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures -- Part 12: Performance measuring and monitoring devices (PMD)
IEC TS 61850-2:2003 Communication networks and systems in substations - Part 2: Glossary
CSA C60044-8 : 2007 : R2011 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS
BS EN 60044-8:2002 Instrument transformers Electronic current transformers
S.R. CLC/TS 50549-2:2015 REQUIREMENTS FOR GENERATING PLANTS TO BE CONNECTED IN PARALLEL WITH DISTRIBUTION NETWORKS - PART 2: CONNECTION TO A MV DISTRIBUTION NETWORK
IEC 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements
BS EN 61869-6:2016 Instrument transformers Additional general requirements for low-power instrument transformers
DD IEC/TS 61850-2:2003 Communication networks and systems in substations Glossary
BS EN 50327:2003 Railway applications. Fixed installations. Harmonisation of the rated values for converter groups and tests on converter groups
BS EN 62689-2:2017 Current and voltage sensors or detectors, to be used for fault passage indication purposes System aspects
CEI EN 61850-9-1 : 2015 COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SYSTEM MAPPINGS (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK
NF EN 60044-8 : 2006 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSDUCERS
CSA C60044-8 :2007 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRANSFORMERS
I.S. EN 61557-12:2008 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD)
I.S. EN 62271-205:2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
IEC 61869-9:2016 Instrument transformers - Part 9: Digital interface for instrument transformers
IEC 60044-8:2002 Instrument transformers - Part 8: Electronic current transformers
CEI EN 60044-8 : 2004 INSTRUMENT TRANSFORMERS - PART 8: ELECTRONIC CURRENT TRASFORMERS
BS EN 61850-9-1:2003 Communication networks and systems in substations. Specific communication service mapping (SCSM) Sampled values over serial unidirectional multidrop point to point link
EN 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 1: General principles and requirements
BS EN 62689-1:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes General principles and requirements
BS EN 60688:2013 Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals
IEC 61557-12:2007 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD)
CLC/TS 50549-2:2015 Requirements for generating plants to be connected in parallel with distribution networks - Part 2: Connection to a MV distribution network
I.S. EN 61850-9-1:2003 COMMUNICATION NETWORKS AND SYSTEMS IN SUBSTATIONS - PART 9-1: SPECIFIC COMMUNICATION SERVICE MAPPING (SCSM) - SAMPLED VALUES OVER SERIAL UNIDIRECTIONAL MULTIDROP POINT TO POINT LINK
I.S. EN 62689-2:2017 CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 2: SYSTEM ASPECTS
IEEE C37.233 : 2009 GUIDE FOR POWER SYSTEM PROTECTION TESTING
I.S. EN 62689-1:2016 CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS
CEI EN 60255-1 : 2011 MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS
CEI EN 61557-12 : 2013 ELECTRICAL SAFETY IN LOW VOLTAGE DISTRIBUTION SYSTEMS UP TO 1000 V A.C. AND 1500 V D.C. - EQUIPMENT FOR TESTING, MEASURING OR MONITORING OF PROTECTIVE MEASURES - PART 12: PERFORMANCE MEASURING AND MONITORING DEVICES (PMD)
IEC 62689-2:2016 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects
CEI EN 62271-205 : 2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 205: COMPACT SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
IEC 60255-1:1967 Electrical relays - Part 1: Instantaneous all-or-nothing relays
IEC 60688:2012 Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals
UNE-EN 60255-1:2010 Measuring relays and protection equipment -- Part 1: Common requirements
IEC 61850-9-1:2003 Communication networks and systems in substations - Part 9-1: Specific Communication Service Mapping (SCSM) - Sampled values over serial unidirectional multidrop point to point link
IEC TR 61869-103:2012 Instrument transformers - The use of instrument transformers for power quality measurement
IEC 62271-205:2008 High-voltage switchgear and controlgear - Part 205: Compact switchgear assemblies for rated voltages above 52 kV
UNE-EN 60688:2013 Electrical measuring transducers for converting A.C. and D.C. electrical quantities to analogue or digital signals
15/30328086 DC BS EN 61557-12. Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. Equipment for testing, measuring or monitoring of protective measures. Part 12. Power metering and monitoring devices (PMD)
10/30215568 DC : 0 BS EN 60255-121 - MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 121: FUNCTIONAL REQUIREMENTS FOR DISTANCE PROTECTION
BS EN 61557-12:2008 Electrical safety in low voltage distribution systems up to 1000 V a.c. and 1500 V d.c. Equipment for testing, measuring or monitoring of protective measures Performance measuring and monitoring devices (PMD)
EN 62689-2:2017 Current and voltage sensors or detectors, to be used for fault passage indication purposes - Part 2: System aspects
12/30268049 DC : 0 BS EN 62689-1 - CURRENT AND VOLTAGE SENSORS OR DETECTORS, TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: GENERAL PRINCIPLES AND REQUIREMENTS
BS EN 62271-205:2008 High-voltage switchgear and controlgear Compact switchgear assemblies for rated voltages above 52 kV
14/30300261 DC : 0 BS EN 62689-1 ED 1.0 - CURRENT AND VOLTAGE SENSORS OR DETECTORS TO BE USED FOR FAULT PASSAGE INDICATION PURPOSES - PART 1: SYSTEM ASPECTS
I.S. EN 60688:2013 ELECTRICAL MEASURING TRANSDUCERS FOR CONVERTING A.C. AND D.C. ELECTRICAL QUANTITIES TO ANALOGUE OR DIGITAL SIGNALS (IEC 60688:2012 (EQV))
NF EN 60255-1 : 2010 MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS
I.S. EN 60255-1:2010 MEASURING RELAYS AND PROTECTION EQUIPMENT - PART 1: COMMON REQUIREMENTS
IEC 61972:2002 Method for determining losses and efficiency of three-phase cage induction motors
EN 50327 : 2003 AMD 1 2005 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - HARMONISATION OF THE RATED VALUES FOR CONVERTER GROUPS AND TESTS ON CONVERTER GROUPS
EN 61557-12:2008 Electrical safety in low voltage distribution systems up to 1 000 V a.c. and 1 500 V d.c. - Equipment for testing, measuring or monitoring of protective measures - Part 12: Performance measuring and monitoring devices (PMD)
EN 60255-1:2010 Measuring relays and protection equipment - Part 1: Common requirements
EN 60044-8:2002 Instrument transformers - Part 8: Electronic current transformers

IEC 60255-22-1:2007 Measuring relays and protection equipment - Part 22-1: Electrical disturbance tests - 1 MHz burst immunity tests
IEC 60038:2009 IEC standard voltages
IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 60044-2:1997+AMD1:2000+AMD2:2002 CSV Instrument transformers - Part 2 : Inductive voltage transformers
IEC 61000-4-8:2009 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 60255-11:2008 Measuring relays and protection equipment - Part 11: Voltage dips, short interruptions, variations and ripple on auxiliary power supply port
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
EN 50081-2:1993 Electromagnetic compatibility - Generic emission standard - Part 2: Industrial environment
IEC 60617-1:1985 Graphical symbols for diagrams. Part 1: General information, general index. Cross-reference tables
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 60255-5:2000 Electrical Relays - Part 5: Insulation coordination for measuring relays and protection equipment - Requirements and tests
IEC 60255-6:1988 Electrical relays - Part 6: Measuring relays and protection equipment
IEC 60050-321:1986 International Electrotechnical Vocabulary (IEV) - Part 321: Instrument transformers
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
IEC 60186:1987 Voltage transformers
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
IEC 60071-1:2006+AMD1:2010 CSV Insulation co-ordination - Part 1: Definitions, principles and rules

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.