I.S. TR 50090-9-2:2007
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 9-2: INSTALLATION REQUIREMENTS - INSPECTION AND TESTING OF HBES INSTALLATION
Hardcopy , PDF
06-09-2016
English
01-24-2008
1 Scope
2 Normative references
3 Definitions
4 General requirements
4.1 Competency of inspectors and commissioning engineers
4.2 Use of standard based products and non-standard based
products
4.3 Reports
4.4 Alternative cabling solutions
5 Purpose of inspection
5.1 General
5.2 Initial inspection
5.3 Periodic inspection
5.4 Path to inspecting a HBES
5.5 Visual inspection
6 Testing and commissioning
6.1 General
6.2 Passive testing and inspecting
6.3 Pre-commissioning
6.4 Commissioning
6.5 Reporting
7 Handover documentation
7.1 Initial handover
Annex A (informative) Handover declaration and report
Annex B (informative) Conforming standards
Annex C (informative) HBES installation inspection schedule
Annex D (informative) Cable test schedule, inspection and
test record
Annex E (informative) HBES loop test acceptance sheet
Annex F (informative) Declaration of final commissioning and
report
Bibliography
Gives the specific requirements for inspectors and commissioning engineers, on checking and approving HBES installations in order to ensure its quality and safe operation.
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
CLC/TR 50090-9-2:2007 | Identical |
EN 50081-1:1992 | Electromagnetic compatibility - Generic emission standard - Part 1: Residential, commercial and light industry |
EN 50346 : 2002 AMD 2 2009 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - TESTING OF INSTALLED CABLING |
EN 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements |
EN 50174-1:2009/A2:2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE |
BS PAS 35(2002) : 2002 | SPECIFICATION FOR WHEELED SPORTS FACILITIES |
ISO 16484-2:2004 | Building automation and control systems (BACS) — Part 2: Hardware |
EN 45011:1998 | General requirements for bodies operating product certification systems (ISO/IEC Guide 65:1996) |
EN 50132-5:2001 | Alarm systems - CCTV surveillance systems for use in security applications - Part 5: Video transmission |
EN 12599:2012 | Ventilation for buildings - Test procedures and measurement methods to hand over air conditioning and ventilation systems |
EN 45011 : 1998 | GENERAL REQUIREMENTS FOR BODIES OPERATING PRODUCT CERTIFICATION SYSTEMS |
CEN/TS 54-14:2004 | Fire detection and fire alarm systems - Part 14: Guidelines for planning, design, installation, commissioning, use and maintenance |
EN 50090-2-2:1996/A2:2007 | HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 2-2: SYSTEM OVERVIEW - GENERAL TECHNICAL REQUIREMENTS |
EN 1434-6:2015 | Heat meters - Part 6: Installation, commissioning, operational monitoring and maintenance |
EN 50098-1 : 98 COR 1 2003 | CUSTOMER PREMISES CABLING FOR INFORMATION TECHNOLOGY - PART 1: ISDN BASIC ACCESS |
EN 50174-2 : 2009 AMD 2 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS |
EN 50110-1:2013 | Operation of electrical installations - Part 1: General requirements |
ISO 3977-8:2002 | Gas turbines — Procurement — Part 8: Inspection, testing, installation and commissioning |
EN 45020:2006 | Standardization and related activities - General vocabulary (ISO/IEC Guide 2:2004) |
EN 50098-2:1996 | Customer premises cabling for Information Technology - Part 2: 2048 kbit/s ISDN primary access and leased line network interface |
ISO/IEC Guide 2:2004 | Standardization and related activities — General vocabulary |
ISO/IEC Guide 65:1996 | General requirements for bodies operating product certification systems |
IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
EN 45020 : 2006 | STANDARDIZATION AND RELATED ACTIVITIES - GENERAL VOCABULARY |
EN 50090-9-1:2004 | Home and Building Electronic Systems (HBES) - Part 9-1: Installation requirements - Generic cabling for HBES Class 1 Twisted Pair |
EN 50173 : 95 AMD 1 2000 | INFORMATION TECHNOLOGY - GENERIC CABLING SYSTEMS |
EN 50110-2:2010 | Operation of electrical installations - Part 2: National annexes |
EN 14336:2004 | Heating systems in buildings - Installation and commissioning of water based heating systems |
EN 50132-7:2012 | Alarm systems - CCTV surveillance systems for use in security applications - Part 7: Application guidelines |
EN ISO 16484-2:2004 | Building automation and control systems (BACS) - Part 2: Hardware (ISO 16484-2:2004) |
EN 50133-1 : 1996 AMD 1 2002 | ALARM SYSTEMS - ACCESS CONTROL SYSTEMS FOR USE IN SECURITY APPLICATIONS - PART 1: SYSTEM REQUIREMENTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.