I.S. HD 637:1999
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
POWER INSTALLATIONS EXCEEDING 1 KV A.C.
Hardcopy , PDF
11-22-2010
English
01-01-1999
FOREWORD
1 SCOPE AND NORMATIVE REFERENCES
2 DEFINITIONS
2.1 GENERAL DEFINITIONS
2.2 INSTALLATIONS
2.3 TYPES OF INSTALLATIONS
2.4 SAFETY MEASURES AGAINST ELECTRIC SHOCK
2.5 CLEARANCES
2.6 CONTROL AND PROTECTION
2.7 EARTHING
3 FUNDAMENTAL REQUIREMENTS
3.1 ELECTRICAL REQUIREMENTS
3.1.1 Methods of neutral earthing
3.1.2 Voltage classification
3.1.3 Current in normal operation
3.1.4 Short circuit current
3.1.5 Rated frequency
3.1.6 Corona
3.2 MECHANICAL REQUIREMENTS
3.2.1 Tension load
3.2.2 Erection load
3.2.3 Ice load
3.2.4 Wind load
3.2.5 Switching forces
3.2.6 Short-circuit forces
3.2.7 Loss of conductor tension
3.2.8 Vibration
3.2.9 Dimensioning of supporting structures
3.3 CLIMATIC AND ENVIRONMENTAL CONDITIONS
3.3.1 Temperature
3.3.2 Altitude and air pressure
3.3.3 Humidity
3.3.4 Precipitation
3.3.5 Pollution
3.3.6 Solar radiation
3.4 SPECIAL REQUIREMENTS
3.4.1 Installations at high altitudes
3.4.2 Effects of small animals and microorganisms
3.4.3 Noise level
3.4.4 Effects of earthquakes
4 INSULATION
4.1 SELECTION OF INSULATION LEVEL
4.2 VERIFICATION OF WITHSTAND VALUES
4.3 MINIMUM CLEARANCES OF LIVE PARTS
4.4 MINIMUM CLEARANCES BETWEEN PARTS UNDER SPECIAL
CONDITIONS
4.5 TESTED CONNECTION ZONES
5 EQUIPMENT
5.1 COMMON RULES
5.1.1 General
5.1.2 Installation
5.2 SPECIFIC REQUIREMENTS
5.2.1 Circuit-breakers, switch-disconnectors, fuses,
fuse-switch disconnectors, contactors,
disconnectors and earthing switches
5.2.2 Power transformers and reactors
5.2.3 Gas insulated metal-enclosed switchgear (GIS),
metal-enclosed switchgear, insulation-enclosed
switchgear and other prefabricated type-tested
switchgear assemblies
5.2.4 Instrument transformers
5.2.5 Surge arresters
5.2.6 Capacitors
5.2.7 Line traps
5.2.8 Insulators
5.2.9 Insulated cables
5.2.10 Conductors and accessories
5.2.11 Rotating machines
5.2.12 Static converters
6 INSTALLATIONS
6.1 GENERAL REQUIREMENTS
6.1.1 Circuit arrangement
6.1.2 Documentation
6.1.3 Transport routes
6.1.4 Aisles and access areas
6.1.5 Lighting
6.1.6 Operational safety
6.1.7 Labelling
6.2 OPEN-TYPE OUTDOOR INSTALLATIONS
6.2.1 Barrier clearances
6.2.2 Obstacle clearances
6.2.3 Boundary clearances
6.2.4 Minimum height over access area
6.2.5 Clearances to buildings
6.2.6 External fences and access doors
6.3 OPEN-TYPE INDOOR INSTALLATIONS
6.4 INSTALLATION OF FACTORY-BUILT TYPE-TESTED
ENCLOSED SWITCHGEAR
6.4.1 General
6.4.2 Additional requirements for gas-insulated
metal-enclosed switchgear
6.5 REQUIREMENTS FOR BUILDINGS
6.5.1 Introduction
6.5.2 Structural provisions
6.5.3 Rooms for switchgear
6.5.4 Service areas
6.5.5 Doors
6.5.6 Draining of dielectric fluids
6.5.7 Air conditioning and ventilation
6.5.8 Building which require special consideration
6.6 HIGH-VOLTAGE/LOW-VOLTAGE PREFABRICATED SUBSTATIONS
6.7 MAST POLE AND TOWER INSTALLATIONS
7 SAFETY MEASURES
7.1 PROTECTION AGAINST DIRECT CONTACT
7.1.1 General
7.1.2 Measures for protection against direct
contact
7.1.3 Protection requirements
7.2 MEANS TO PROTECT PERSONS IN CASE OF INDIRECT CURRENT
7.3 MEANS TO PROTECT PERSONS WORKING ON ELECTRICAL
INSTALLATIONS
7.3.1 Equipment for isolating installations or
apparatus
7.3.2 Devices to prevent reclosing of isolating
devices
7.3.3 Devices for determining the de-energized
state
7.3.4 Devices for earthing and short-circuiting
7.3.5 Equipment acting as barriers against
adjacent live parts
7.3.6 Storage of accident prevention equipment
7.4 PROTECTION FROM DANGERS RESULTING FROM ARC FAULT
7.5 PROTECTION AGAINST DIRECT LIGHTNING STROKES
7.6 PROTECTION AGAINST FIRE
7.6.1 General
7.6.2 Transformers, reactors
7.6.3 Cables and flexible cords
7.6.4 Other equipment with flammable liquid
7.7 PROTECTION AGAINST LEAKAGE OF INSULATING LIQUID AND
SF[6]
7.7.1 Insulating liquid leakage and subsoil water
protection
7.7.2 SF[6]-leakage (new SF[6])
7.7.3 Failure with loss of SF[6] and its
decomposition products
7.8 IDENTIFICATION AND MARKING
7.8.1 General
7.8.2 Information plates and warning plates
7.8.3 Electrical hazard warning
7.8.4 Installations with incorporated capacitors
7.8.5 Emergency signs for emergency exits
8 AUXILIARY INSTALLATIONS AND CONTROL SYSTEMS
8.1 MONITORING AND CONTROL SYSTEMS
8.2 DC AND AC SUPPLY CIRCUITS
8.2.1 AC supply
8.2.2 DC supply
8.3 COMPRESSED AIR SYSTEMS
8.4 SF[6] GAS HANDLING PLANTS
8.5 BASIC RULES FOR ELECTO-MAGNETIC COMPATIBILITY OF
CONTROL SYSTEMS
8.5.1 Electrical noise sources in high voltage
installations
8.5.2 Measures to be taken to reduce the effects
of high frequency interference
8.5.3 Measures to be taken to reduce the effects
of low frequency interference
8.5.4 Measures related to the selection of
equipment
8.5.5 Other possible measures to reduce the
effects of interference
9 EARTHING SYSTEMS
9.1 PURPOSE
9.2 DIMENSIONING OF EARTHING SYSTEMS AT POWER FREQUENCY
9.2.1 General
9.2.2 Dimensioning with respect to corrosion and
mechanical strength
9.2.3 Dimensioning with respect to thermal strength
9.2.4 Dimensioning with regard to touch and step
voltages
9.3 CONSTRUCTION OF EARTHING SYSTEMS
9.3.1 Installation of earth electrodes and
earthing conductors
9.3.2 Measures to be taken to reduce the effects
of high frequency interference
9.3.3 Transferred potentials
9.3.4 Measures for earthing on equipment and
installations
9.4 COMMON EARTHING SYSTEM FOR HIGH VOLTAGE AND LOW
VOLTAGE SYSTEMS
9.4.1 Conditions for a common earthing system
9.4.2 Supply of low voltage installations inside
the area of a high voltage earthing system
9.4.3 Supply of low voltage installations outside
the area of a high voltage earthing system
9.4.4 Separated earthing systems
9.5 EARTHING MEASURES AGAINST LIGHTNING EFFECTS
9.6 MEASUREMENTS FOR AND ON EARTHING SYSTEMS
9.7 SITE INSPECTION AND DOCUMENTATION OF EARTHING SYSTEMS
9.8 GENERAL COMMENTS ON CHECKING AND SUPERVISION OF
EARTHING SYSTEMS
9.8.1 Checking by inspection
9.8.2 Checking by measurement or calculation
10 INSPECTION AND TESTING ON SITE BEFORE TAKING OVER
ANNEX A (NORMATIVE) TYPE AND MINIMUM DIMENSIONS OF EARTH
ELECTRODE MATERIALS ENSURING MECHANICAL STRENGTH
AND CORROSION RESISTANCE
ANNEX B (NORMATIVE) CURRENT RATING CALCULATION OF EARTHING
CONDUCTORS AND EARTH ELECTRODES
ANNEX C (NORMATIVE) TOUCH VOLTAGE AND BODY CURRENT
C.1 EQUIVALENCE BETWEEN TOUCH VOLTAGE AND BODY CURRENT
C.2 TAKING INTO ACCOUNT ADDITIONAL RESISTANCES
ANNEX D (NORMATIVE) DESCRIPTION OF THE RECOGNIZED SPECIFIED
MEASURES M
ANNEX E (NORMATIVE) MEASURES ON EARTHING SYSTEMS TO REDUCE
THE EFFECTS OF HIGH FREQUENCY INTERFERENCE
ANNEX F (NORMATIVE) DETAILED MEASURES FOR EARTHING OF
EQUIPMENT AND INSTALLATIONS
F.1 FENCES AROUND SUBSTATION INSTALLATIONS
F.2 PIPES
F.3 TRACTION RAILS
F.4 POLE MOUNTED TRANSFORMING AND/OR SWITCHING
INSTALLATIONS
F.5 SECONDARY CIRCUITS OF INSTRUMENT TRANSFORMERS
ANNEX G (NORMATIVE) MEASURING TOUCH VOLTAGES
ANNEX H (INFORMATIVE) METHODS OF PROTECTION AGAINST DIRECT
LIGHTNING STROKES
H.1 SHIELD WIRES
H.2 LIGHTNING RODS
ANNEX J (INFORMATIVE) REDUCTION FACTORS RELATED TO EARTH
WIRES OF OVERHEAD LINES AND METAL SHEATHS OF
UNDERGROUND CABLES
J.1 GENERAL
J.2 TYPICAL VALUES OF REDUCTION FACTORS OF OVERHEAD
LINES AND CABLES (50 Hz)
ANNEX K (INFORMATIVE) BASIS FOR THE DESIGN OF EARTHING
SYSTEMS
K.1 SOIL RESISTIVITY
K.2 RESISTANCE TO EARTH
ANNEX L (INFORMATIVE) INSTALLING THE EARTH ELECTRODES
AND EARTHING CONDUCTORS
L.1 INSTALLATION OF EARTH ELECTRODES
L.1.1 Horizontal earth electrodes
L.1.2 Vertical or inclined driven rods
L.1.3 Jointing the earth electrodes
L.2 INSTALLATION OF EARTHING CONDUCTORS
L.2.1 Installing the earthing conductors
L.2.2 Jointing the earthing conductors
ANNEX M (INFORMATIVE) APPROXIMATE FORMULAE FOR SIMPLE
EARTHING SYSTEMS: APPROPRIATE DISTANCES TO AVOID
DANGEROUS VOLTAGES
ANNEX N (INFORMATIVE) MEASUREMENTS FOR AND ON EARTHING
SYSTEMS
N.1 MEASUREMENT OF SOIL RESISTIVITIES
N.2 MEASUREMENT OF RESISTANCES TO EARTH AND IMPEDANCES
TO EARTH
N.3 DETERMINATION OF THE EARTH POTENTIAL RISE
N.4 ELIMINATION OF INTERFERENCE AND DISTURBANCE
VOLTAGES FOR EARTHING MEASUREMENTS
ANNEX P (INFORMATIVE) DETAILS ON SITE INSPECTION AND
DOCUMENTATION OF EARTHING SYSTEMS
ANNEX Q (INFORMATIVE) EXAMPLES FOR CHECKING THE CORRECT
DESIGN CONCERNING THE PERMISSIBLE TOUCH VOLTAGE
ANNEX R (INFORMATIVE) THE USE OF REINFORCING BARS IN
CONCRETE FOR EARTHING PURPOSE
ANNEX S (INFORMATIVE) A-DEVIATIONS
A-DEVIATIONS FOR BELGIUM
A-DEVIATIONS FOR SWITZERLAND
A-DEVIATIONS FOR SPAIN
A-DEVIATIONS FOR FINLAND
A-DEVIATIONS FOR FRANCE
A-DEVIATIONS FOR UNITED KINGDOM
A-DEVIATIONS FOR ITALY
A-DEVIATIONS FOR SWEDEN
ANNEX T (NORMATIVE) SPECIAL NATIONAL CONDITIONS AND
NATIONAL PROVISIONS (PART OF NATIONAL STANDARDS,
SPECIFICATIONS OR PRACTICES)
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
CZECH REPUBLIC
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
DENMARK
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
FINLAND
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
FRANCE
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
UNITED KINGDOM
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
ITALY
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
THE NETHERLANDS
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
NORWAY
SPECIAL NATIONAL CONDITIONS AND NATIONAL PROVISIONS FOR
SWEDEN
ANNEX U (INFORMATIVE) BIBLIOGRAPHY
Provides the requirements for the design and erection of electrical installations, in systems with nominal voltage above 1 kV a.c., so as to provide safety and proper functioning for the use intended.
DocumentType |
Standard
|
Pages |
174
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
HD 637 S1:1999/corrigendum:2005 | Identical |
EN 60517:1996/A11:1999 | GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES OF 72,5 KV AND ABOVE |
IEC 60826:2017 | Design criteria of overhead transmission lines |
EN 60721-3-1:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 1: Storage |
HD 464 : S1 AMD 5 2002 | DRY-TYPE POWER TRANSFORMERS |
IEC 60724:2000+AMD1:2008 CSV | Short-circuit temperature limits of electric cables with rated voltages of 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) and 3 kV (<em>U</em><sub>m</sub> = 3,6 kV) |
ISO 1996-2:2017 | Acoustics — Description, measurement and assessment of environmental noise — Part 2: Determination of sound pressure levels |
EN 61219:1993 | Live working - Earthing or earthing and short-circuiting equipment using lances as short-circuiting device - Lance earthing |
EN 60623:2017 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Vented nickel-cadmium prismatic rechargeable single cells |
EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
EN 61230:2008 | LIVE WORKING - PORTABLE EQUIPMENT FOR EARTHING OR EARTHING AND SHORT-CIRCUITING |
EN 60721-3-9:1993/A1:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 9: MICROCLIMATES INSIDE PRODUCTS |
EN 60721-3-5:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 5: Ground vehicle installations |
IEC 60478-1:1974 | Stabilized power supplies, d.c. output. Part 1: Terms and definitions |
HD 606.1 : 200S1 | MEASUREMENT OF SMOKE DENSITY OF ELECTRIC CABLES BURNING UNDER DEFINED CONDITIONS - TEST APPARATUS |
EN 60896-1:1991/A2:1992 | STATIONARY LEAD-ACID BATTERIES - GENERAL REQUIREMENTS AND METHODS OF TEST - VENTED TYPES |
EN 60721-3-0:1993 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Introduction |
IEC 61243-3:2014 | Live working - Voltage detectors - Part 3: Two-pole low-voltage type |
IEC 60949:1988 | Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects |
EN 61100:1992 | Classification of insulating liquids according to fire point and net calorific value |
IEC 61243-2:1995+AMD1:1999+AMD2:2002 CSV | Live working - Voltage detectors - Part 2: Resistive type to be used for voltages of 1 kV to 36 kV a.c. |
EN 50017:1998 | Electrical apparatus for potentially explosive atmospheres - Powder filling "q" |
EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
EN 60721-3-7:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 7: PORTABLE AND NON-STATIONARY USE |
HD 606.2 : 200S1 | MEASUREMENT OF SMOKE DENSITY OF ELECTRIC CABLES BURNING UNDER DEFINED CONDITIONS - TEST PROCEDURE AND REQUIREMENTS |
EN 50018 : 2000 AMD 1 2002 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - FLAMEPROOF ENCLOSURE "D" |
HD 472 S1:1989/AC:2013 | NOMINAL VOLTAGES FOR LOW-VOLTAGE PUBLIC ELECTRICITY SUPPLY SYSTEMS |
EN 60255-6 : 94 AC 95 | ELECTRICAL RELAYS - MEASURING RELAYS AND PROTECTION EQUIPMENT |
IEC 61243-1:2003+AMD1:2009 CSV | Live working - Voltage detectors - Part 1: Capacitive type to be used for voltages exceeding 1 kV a.c. |
EN 60060-2:2011 | High-voltage test techniques - Part 2: Measuring systems |
EN 60298:1996/A11:1999 | A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV |
IEC 60044-6:1992 | Instrument transformers - Part 6: Requirements for protective current transformers for transient performance |
EN 61330:1996 | High-voltage/low-voltage prefabricated substations |
EN 60694:1996/A2:2001 | COMMON SPECIFICATIONS FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR STANDARDS |
ISO 1996-3:1987 | Acoustics Description and measurement of environmental noise Part 3: Application to noise limits |
EN 50110-1:2013 | Operation of electrical installations - Part 1: General requirements |
IEC 61243-5:1997 | Live working - Voltage detectors - Part 5: Voltage detecting systems (VDS) |
ISO 1996-1:2016 | Acoustics Description, measurement and assessment of environmental noise Part 1: Basic quantities and assessment procedures |
IEC 60478-2:1986 | Stabilized power supplies, d.c. output. Part 2: Rating and performance |
EN 60865-1:2012 | Short-circuit currents - Calculation of effects - Part 1: Definitions and calculation methods |
EN 60071-1:2006/A1:2010 | INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES |
EN 50265-2-2:1998 | Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-2: Procedures - Diffusion flame |
IEC 60287-3-1:2017 | Electric cables - Calculation of the current rating - Part 3-1: Operating conditions - Site reference conditions |
EN 61082-1:2015 | Preparation of documents used in electrotechnology - Part 1: Rules |
IEC 60478-5:1993 | Stabilized power supplies, d.c. output - Part 5: Measurement of the magnetic component of the reactive near field |
EN 60071-2:1997 | Insulation co-ordination - Part 2: Application guide |
ENV 61024-1 : DRAFT 1995 | PROTECTION OF STRUCTURES AGAINST LIGHTNING - GENERAL PRINCIPLES |
EN 60622:2003 | Secondary cells and batteries containing alkaline or other non-acid electrolytes - Sealed nickel-cadmium prismatic rechargeable single cells |
EN 50267-2-3:1998 | Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity |
IEC 60478-4:1976 | Stabilized power supplies, d.c. output. Part 4: Tests other than radio-frequency interference |
EN 60721-1:1995/A2:1995 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 1: ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES |
EN 50015:1998 | Electrical apparatus for potentially explosive atmospheres - Oil immersion "o" |
EN 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
HD 405.3 : 200S1 | TESTS OF ELECTRIC CABLES UNDER FIRE CONDITIONS - TESTS ON BUNCHED WIRES OR CABLES |
EN 50016:2002 | Electrical apparatus for potentially explosive atmospheres - Pressurized apparatus "p" |
HD 384.4.442 : 200S1 | ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 44: PROTECTION AGAINST OVERVOLTAGES - SECTION 442: PROTECTION OF LOW-VOLTAGE INSTALLATIONS AGAINST FAULTS BETWEEN HIGH-VOLTAGE SYSTEMS AND EARTH |
HD 384.3 : 200S2 | ELECTRICAL INSTALLATIONS OF BUILDINGS - ASSESSMENT OF GENERAL CHARACTERISTICS |
EN 60076-2:2011 | Power transformers - Part 2: Temperature rise for liquid-immersed transformers |
IEC 60331:1970 | Fire-resisting characteristics of electric cables |
EN 50028:1987 | Electrical apparatus for potentially explosive atmospheres - Encapsulation 'm' |
EN 60721-3-4:1995/A1:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SECTION 4: STATIONARY USE AT NON-WEATHER-PROTECTED LOCATIONS |
EN 50014:1997/A2:1999 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
EN 50110-2:2010 | Operation of electrical installations - Part 2: National annexes |
EN 60721-3-6:1993/A2:1997 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - PART 3: CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - SHIP ENVIRONMENT |
EN 50265-1:1998 | Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 1: Apparatus |
IEC 60478-3:1989 | Stabilized power supplies, d.c. output. Part 3: Reference levels and measurement of conducted electromagnetic interference (EMI) |
EN 60617-13:1993 | Graphical symbols for diagrams - Part 13: Analogue elements |
HD 246.2 : 200S1 | DIAGRAMS, CHARTS, TABLES - ITEM DESIGNATION |
EN 50265-2-1:1998 | Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame |
EN 60721-3-3 : 95 AMD 2 97 | CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS |
HD 533 : 200S1 | SHORT-CIRCUIT CALCULATION IN THREE-PHASE A.C. SYSTEMS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.