• Shopping Cart
    There are no items in your cart

I.S. HD 620:2010

Current

Current

The latest, up-to-date edition.

DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2010

Preview
US$521.55
Excluding Tax where applicable

PART 1 - General requirements
PART 9 - HEPR insulated single core cables, and single
         core pre-assembled cables
PART 10 - XLPE insulated single core and 3 core cables,
          and single core pre-assembled cables
PART 11 - EPR insulated single core and 3 core cables

Defines the general requirements applicable to these cables, unless otherwise specified in the particular sections of this HD.

DevelopmentNote
Supersedes I.S. HD 620 PTS 1-5 and I.S. HD 620 PTS 6-9. (02/2010)
DocumentType
Standard
Pages
662
PublisherName
National Standards Authority of Ireland
Status
Current
Supersedes

Standards Relationship
HD 620 : 2010 Identical

EN 60229:2008 Electric cables - Tests on extruded oversheaths with a special protective function
EN 10002-1 : 2001 METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE
EN 60332-3-23:2009 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-23: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY B
HD 632 : 1998 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
EN 60332-3-21:2009 Tests on electric and optical fibre cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R
IEC 60228:2004 Conductors of insulated cables
IEC 60986:2000+AMD1:2008 CSV Short-circuit temperature limits of electric cables with rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
EN 50267-2-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-1: Procedures - Determination of the amount of halogen acid gas
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
EN 50307:2002 Lead and lead alloys - Lead and lead alloy sheaths and sleeves of electric cables
IEC 60332-3-23:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-23: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category B
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
IEC 60885-3:2015 RLV Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
IEC 60888:1987 Zinc-coated steel wires for stranded conductors
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
IEC 60949:1988 Calculation of thermally permissible short-circuit currents, taking into account non-adiabatic heating effects
ISO 6507-3:2005 Metallic materials Vickers hardness test Part 3: Calibration of reference blocks
IEC 60332-3-24:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-24: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category C
IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
EN 50267-1:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 1: Apparatus
NEN NPR 3626 : 1994 AMD 2 2011 CABLES WITH INSULATION OF CROSS-LINKED POLYETHYLENE FOR VOLTAGES OF 6 KV UP TO AND INCLUDING 30 KV - CONTINUOUS CURRENT RATING AND THERMALLY PERMISSIBLE SHORT-CIRCUIT CURRENT
HD 626 S1:1996/A2:2002 OVERHEAD DISTRIBUTION CABLES OF RATED VOLTAGE U[O]/U(U[M]): 0,6/1 (1,2) KV
IEC 60230:1966 Impulse tests on cables and their accessories
EN 60332-1-1:2004/A1:2015 Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
EN 60332-3-10:2009 Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
EN 61034-2:2005/A1:2013 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013)
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
IEC 62230:2006+AMD1:2013 CSV Electric cables - Spark-test method
IEC 60332-3-21:2000 Tests on electric cables under fire conditions - Part 3-21: Test for vertical flame spread of vertically-mounted bunched wires or cables - Category A F/R
ISO 9001:2015 Quality management systems — Requirements
EN 61034-1:2005/A1:2014 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 1: TEST APPARATUS (IEC 61034-1:2005/A1:2013)
EN 50182:2001/AC:2013 CONDUCTORS FOR OVERHEAD LINES - ROUND WIRE CONCENTRIC LAY STRANDED CONDUCTORS
EN 50267-2-3:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
IEC 60229:2007 Electric cables - Tests on extruded oversheaths with a special protective function
EN 60885-3:2015 Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
HD 361 : S3 AMD 1 2006 SYSTEM FOR CABLE DESIGNATION
EN 60230:2002 Impulse tests on cables and their accessories
EN 62230:2007/A1:2014 ELECTRIC CABLES - SPARK-TEST METHOD
EN 60332-3-24:2009 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 3-24: TEST FOR VERTICAL FLAME SPREAD OF VERTICALLY-MOUNTED BUNCHED WIRES OR CABLES - CATEGORY C
EN 50414:2006 Test methods for analysis of lead in PVC taken from insulation and sheath of electric and optical fibre cables - Method A: Total lead content determination with flame excitation atomic absorption spectrometry - Method B: Qualitative analysis of lead by lead sulphide staining
EN 50334:2001 Marking by inscription for the identification of cores of electric cables
IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
EN 50267-2-2:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-2: Procedures - Determination of degree of acidity of gases for materials by measuring pH and conductivity
IEC 60332-3-10:2000+AMD1:2008 CSV Tests on electric and optical fibre cables under fire conditions - Part 3-10: Test for vertical flame spread of vertically-mounted bunched wires or cables - Apparatus
IEC 61034-1:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under defined conditions - Part 1: Test apparatus

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.