I.S. EN ISO 80079-37:2016
Current
The latest, up-to-date edition.
EXPLOSIVE ATMOSPHERES - PART 37: NON-ELECTRICAL EQUIPMENT FOR EXPLOSIVE ATMOSPHERES - NON-ELECTRICAL TYPE OF PROTECTION CONSTRUCTIONAL SAFETY 'C', CONTROL OF IGNITION SOURCES 'B', LIQUID IMMERSION 'K' (ISO/DIS 80079-37:2014)
Hardcopy , PDF
English
01-01-2016
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
European Foreword
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Determination of suitability
5 Requirements for equipment with Type of Protection
constructional safety 'c'
6 Requirements for equipment with Type of Protection
control of ignition source 'b'
7 Requirements for equipment with Type of Protection
liquid immersion 'k'
8 Type tests
9 Documentation
10 Marking
Annex A (informative) - Approach and application:
equipment with Type of Protection 'c'
Annex B (normative) - Test requirements
Annex C (informative) - Methodology: equipment with
Type of Protection 'b'
Annex D (informative) - Approach to assign the required
ignition protection type used for equipment to achieve
different EPL
Annex E (informative) - Information on functional safety
concept
Bibliography
Annex ZA (informative) - Relationship between this
European Standard and the Essential
Requirements of EU Directive 2014/34/EU
Annex ZB (informative) - Significant changes between
this European Standard and EN 13463-5:2011,
EN 13463-6:2005 and EN 13463-8:2003
Defines the requirements for the design and construction of non-electrical equipment, intended for use in explosive atmospheres, protected by the types of protection constructional safety 'c', control of ignition source 'b' and liquid immersion 'k'.
| DevelopmentNote |
Supersedes I.S. EN 13463-5, I.S. EN 13463-6 & I.S. EN 13463-8. (05/2016)
|
| DocumentType |
Standard
|
| Pages |
122
|
| PublisherName |
National Standards Authority of Ireland
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| ISO 80079-37:2016 | Identical |
| EN ISO 80079-37:2016 | Identical |
| ISO 9563:2015 | Belt drives — Electrical conductivity of antistatic endless synchronous belts — Characteristics and test method |
| IEC 61511-1:2016+AMD1:2017 CSV | Functional safety - Safety instrumented systems for the process industry sector - Part 1: Framework, definitions, system, hardware and application programming requirements |
| ISO 4413:2010 | Hydraulic fluid power — General rules and safety requirements for systems and their components |
| EN 13478:2001+A1:2008 | Safety of machinery - Fire prevention and protection |
| IEC 61508-5:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 5: Examples of methods for the determination of safety integrity levels (see Functional Safety and IEC 61508) |
| IEC 61508-4:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 4: Definitions and abbreviations (see Functional Safety and IEC 61508) |
| EN 13237:2012 | Potentially explosive atmospheres - Terms and definitions for equipment and protective systems intended for use in potentially explosive atmospheres |
| IEC 61508-3:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 3: Software requirements (see Functional Safety and IEC 61508) |
| IEC 60079-20-1:2010 | Explosive atmospheres - Part 20-1: Material characteristics for gas and vapour classification - Test methods and data |
| ISO 80079-36:2016 | Explosive atmospheres — Part 36: Non-electrical equipment for explosive atmospheres — Basic method and requirements |
| ISO 281:2007 | Rolling bearings — Dynamic load ratings and rating life |
| EN 14986:2017 | Design of fans working in potentially explosive atmospheres |
| ISO 1813:2014 | Belt drives — V-ribbed belts, joined V-belts and V-belts including wide section belts and hexagonal belts — Electrical conductivity of antistatic belts: Characteristics and methods of test |
| IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
| IEC 60079-6:2015 | Explosive atmospheres - Part 6: Equipment protection by liquid immersion "o" |
| IEC 60079-0:2011 | Explosive atmospheres - Part 0: Equipment - General requirements |
| ISO 4414:2010 | Pneumatic fluid power — General rules and safety requirements for systems and their components |
| IEC 61508-6:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 6: Guidelines on the application of IEC 61508-2 and IEC 61508-3 (see Functional Safety and IEC 61508) |
| IEC 61508-1:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 1: General requirements (see Functional Safety and IEC 61508) |
| IEC 62061:2005+AMD1:2012+AMD2:2015 CSV | Safety of machinery - Functional safety of safety-related electrical, electronic and programmable electronic control systems |
| IEC 61508-7:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 7: Overview of techniques and measures (see Functional Safety and IEC 61508) |
| ISO 13849-1:2015 | Safety of machinery — Safety-related parts of control systems — Part 1: General principles for design |
| EN 50303:2000 | Group I, Category M1 equipment intended to remain functional in atmospheres endangered by firedamp and/or coal dust |
| IEC 61508-2:2010 | Functional safety of electrical/electronic/programmable electronic safety-related systems - Part 2: Requirements for electrical/electronic/programmable electronic safety-related systems (see Functional Safety and IEC 61508) |
| ISO 19353:2015 | Safety of machinery — Fire prevention and fire protection |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.