I.S. EN ISO 14161:2009
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
STERILIZATION OF HEALTH CARE PRODUCTS - BIOLOGICAL INDICATORS - GUIDANCE FOR THE SELECTION, USE AND INTERPRETATION OF RESULTS
Hardcopy , PDF
04-30-2020
English
01-01-2009
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General
5 Characteristics of biological indicators
6 Selection of supplier
7 Biological indicators in process development
8 Biological indicators in sterilization validation
9 Biological indicators in routine monitoring
10 Results
11 Application of biological indicator standards
12 Culture conditions
13 Third-party requirements
14 Personnel training
15 Storage and handling
16 Disposal of biological indicators
Annex A (informative) - Microbiological inactivation
kinetics and enumeration techniques
Annex B (informative) - Process challenge devices
Annex C (informative) - Formulae for fraction negative
methods for D value calculations
Annex D (informative) - Examples of documentation for
biological indicators prepared
by the user
Annex E (informative) - Calculation of z value
Annex F (informative) - D value determination by survivor
curve method
Annex G (informative) - Survival-kill response characteristics
Bibliography
Gives guidance for the selection, use and interpretation of results from application of biological indicators when used in the development, validation and routine monitoring of sterilization processes.
DocumentType |
Standard
|
Pages |
76
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
UNE-EN ISO 14161:2010 | Identical |
NF EN ISO 14161 : 2009 | Identical |
ISO 14161:2009 | Identical |
NS EN ISO 14161 : 2009 | Identical |
UNI EN ISO 14161 : 2009 | Identical |
DIN EN ISO 14161:2010-03 | Identical |
NBN EN ISO 14161 : 2009 | Identical |
SN EN ISO 14161 : 2010 | Identical |
BS EN ISO 14161:2009 | Identical |
EN ISO 14161:2009 | Identical |
NEN EN ISO 14161 : 2009 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 19011:2011 | Guidelines for auditing management systems |
ISO 11138-3:2017 | Sterilization of health care products — Biological indicators — Part 3: Biological indicators for moist heat sterilization processes |
EN 285:2015 | Sterilization - Steam sterilizers - Large sterilizers |
ISO 11737-2:2009 | Sterilization of medical devices Microbiological methods Part 2: Tests of sterility performed in the definition, validation and maintenance of a sterilization process |
ISO 11737-1:2006 | Sterilization of medical devices Microbiological methods Part 1: Determination of a population of microorganisms on products |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 14937:2009 | Sterilization of health care products General requirements for characterization of a sterilizing agent and the development, validation and routine control of a sterilization process for medical devices |
AAMI TIR31 : 2008 | PROCESS CHALLENGE DEVICES/TEST PACKS FOR USE IN HEALTH CARE FACILITIES |
ISO 11138-2:2017 | Sterilization of health care products — Biological indicators — Part 2: Biological indicators for ethylene oxide sterilization processes |
ISO/IEC 17011:2004 | Conformity assessment General requirements for accreditation bodies accrediting conformity assessment bodies |
ISO 11135-1:2007 | Sterilization of health care products Ethylene oxide Part 1: Requirements for development, validation and routine control of a sterilization process for medical devices |
ISO 18472:2006 | Sterilization of health care products Biological and chemical indicators Test equipment |
ISO/TS 11139:2006 | Sterilization of health care products Vocabulary |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
ISO/IEC Guide 2:2004 | Standardization and related activities — General vocabulary |
ISO 11138-1:2017 | Sterilization of health care products — Biological indicators — Part 1: General requirements |
ISO 11138-4:2017 | Sterilization of health care products — Biological indicators — Part 4: Biological indicators for dry heat sterilization processes |
ISO 11138-5:2017 | Sterilization of health care products — Biological indicators — Part 5: Biological indicators for low-temperature steam and formaldehyde sterilization processes |
ISO 17665-1:2006 | Sterilization of health care products — Moist heat — Part 1: Requirements for the development, validation and routine control of a sterilization process for medical devices |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.