I.S. EN ISO 10993-1:2009+AC:2010
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
View Superseded by
BIOLOGICAL EVALUATION OF MEDICAL DEVICES - PART 1: EVALUATION AND TESTING WITHIN A RISK MANAGEMENT PROCESS (ISO 10993-1:2009)
Hardcopy , PDF
06-30-2021
English
01-01-2009
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General principles applying to biological evaluation
of medical devices
5 Categorization of medical devices
6 Biological evaluation process
7 Interpretation of biological evaluation data and overall
biological safety assessment
Annex A (informative) - Biological evaluation tests
Annex B (informative) - Guidance on the risk management process
Annex C (informative) - Suggested procedure for literature review
Bibliography
Annex ZA (informative) - Relationship between this International
Standard and the Essential Requirements of EU
Directive 93/42/EEC on Medical Devices
Annex ZB (informative) - Relationship between this International
Standard and the Essential Requirements of EU
Directive 90/385/EEC on Active Implantable
Medical Devices
Specifies: a) general principles governing the biological evaluation of medical devices; b) the categorization of devices based on the nature and duration of their contact with the body.
Committee |
CEN/TC 206
|
DocumentType |
Standard
|
Pages |
42
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
SupersededBy | |
Supersedes |
Standards | Relationship |
ONORM EN ISO 10993-1 : 2011 | Identical |
ISO 10993-1:2009 | Identical |
NBN EN ISO 10993-1 : 2009 COR 2010 | Identical |
NEN EN ISO 10993-1 : 2009 C1 2010 | Identical |
NS EN ISO 10993-1 : 2009 COR 2010 | Identical |
SN EN ISO 10993-1 : 2010 CORR 2010 | Identical |
UNI EN ISO 10993-1 : 2010 | Identical |
EN ISO 10993-1:2009 | Identical |
BS EN ISO 10993-1 : 2009-10 | Identical |
NF EN ISO 10993-1 : 2010 | Identical |
UNE-EN ISO 10993-1:2010 | Identical |
DIN EN ISO 10993-1:2010-04 | Identical |
ISO/IEC 17025:2005 | General requirements for the competence of testing and calibration laboratories |
ISO 10993-3:2014 | Biological evaluation of medical devices — Part 3: Tests for genotoxicity, carcinogenicity and reproductive toxicity |
ISO 10993-4:2017 | Biological evaluation of medical devices — Part 4: Selection of tests for interactions with blood |
ISO 10993-16:2017 | Biological evaluation of medical devices — Part 16: Toxicokinetic study design for degradation products and leachables |
ISO/TS 10993-20:2006 | Biological evaluation of medical devices — Part 20: Principles and methods for immunotoxicology testing of medical devices |
ISO 10993-13:2010 | Biological evaluation of medical devices — Part 13: Identification and quantification of degradation products from polymeric medical devices |
ISO 13485:2016 | Medical devices Quality management systems Requirements for regulatory purposes |
ISO 10993-2:2006 | Biological evaluation of medical devices — Part 2: Animal welfare requirements |
ISO 7405:2008 | Dentistry Evaluation of biocompatibility of medical devices used in dentistry |
ISO 10993-14:2001 | Biological evaluation of medical devices — Part 14: Identification and quantification of degradation products from ceramics |
ISO 10993-18:2005 | Biological evaluation of medical devices Part 18: Chemical characterization of materials |
ISO/TS 10993-19:2006 | Biological evaluation of medical devices Part 19: Physico-chemical, morphological and topographical characterization of materials |
ISO 10993-10:2010 | Biological evaluation of medical devices Part 10: Tests for irritation and skin sensitization |
ISO 9004:2009 | Managing for the sustained success of an organization A quality management approach |
ISO 10993-11:2017 | Biological evaluation of medical devices — Part 11: Tests for systemic toxicity |
ISO 10993-12:2012 | Biological evaluation of medical devices Part 12: Sample preparation and reference materials |
ISO 10993-7:2008 | Biological evaluation of medical devices Part 7: Ethylene oxide sterilization residuals |
ISO 10993-17:2002 | Biological evaluation of medical devices — Part 17: Establishment of allowable limits for leachable substances |
ISO 9001:2015 | Quality management systems — Requirements |
ISO 10993-9:2009 | Biological evaluation of medical devices Part 9: Framework for identification and quantification of potential degradation products |
ISO 9000:2015 | Quality management systems — Fundamentals and vocabulary |
ISO 14971:2007 | Medical devices Application of risk management to medical devices |
ISO 10993-6:2016 | Biological evaluation of medical devices Part 6: Tests for local effects after implantation |