I.S. EN IEC 62056-6-2:2018
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTRICITY METERING DATA EXCHANGE - THE DLMS/COSEM SUITE - PART 6-2: COSEM INTERFACE CLASSES
Hardcopy , PDF
11-05-2023
English
01-01-2018
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms, definitions and abbreviated terms
4 Basic principles
5 The COSEM interface classes
6 Relation to OBIS
7 Previous versions of interface classes
Annex A (informative) - Additional information on Auto
answer and Auto connect ICs
Annex B (informative) - Additional information to M-Bus
client (class_id = 72, version 1)
Annex C (informative) - Additional information on IPv6
setup class (class_id = 48, version = 0)
Annex D (informative) - Overview of the narrow-band
OFDM PLC technology for PRIME networks
Annex E (informative) - Overview of the narrow-band
OFDM PLC technology for G3-PLC networks
Annex F (informative) - Significant technical changes with
respect to IEC 62056-6-2, Edition 2.0:2016
Bibliography
Index
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Gives a model of a meter as it is seen through its communication interface(s).
DevelopmentNote |
Supersedes and Redesignates I.S. EN 62056-6-2. For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (03/2018)
|
DocumentType |
Standard
|
Pages |
916
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
EN 61334-4-41:1996 | Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 41: Application protocols - Distribution line message specification |
IEC TR 62051:1999 | Electricity metering - Glossary of terms |
ISO/IEC 10646:2014 | Information technology Universal Coded Character Set (UCS) |
EN 61334-4-512:2002 | Distribution automation using distribution line carrier systems - Part 4-512: Data communication protocols - System management using profile 61334-5-1 - Management Information Base (MIB) |
IEC 62056-7-3:2017 | Electricity metering data exchange - The DLMS/COSEM suite - Part 7-3: Wired and wireless M-Bus communication profiles for local and neighbourhood networks |
IEC TR 62055-21:2005 | Electricity metering - Payment systems - Part 21: Framework for standardization |
EN 62056-46:2002/A1:2007 | ELECTRICITY METERING - DATA EXCHANGE FOR METER READING, TARIFF AND LOAD CONTROL - PART 46: DATA LINK LAYER USING HDLC PROTOCOL |
EN 62056-7-3:2017 | Electricity metering data exchange - The DLMS/COSEM suite - Part 7-3: Wired and wireless M-Bus communication profiles for local and neighbourhood networks |
IEC 62056-8-6:2017 | Electricity metering data exchange - The DLMS/COSEM suite - Part 8-6: High speed PLC ISO/IEC 12139-1 profile for neighbourhood networks |
IEEE 802.15.4-2011 | IEEE Standard for Local and metropolitan area networks--Part 15.4: Low-Rate Wireless Personal Area Networks (LR-WPANs) |
IEC 61334-4-32:1996 | Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 32: Data link layer - Logical link control (LLC) |
EN 62056-31:2000 | Electricity metering - Data exchange for meter reading, tariff and load control - Part 31: Use of local area networks on twisted pair with carrier signalling |
IEC 61334-5-1:2001 | Distribution automation using distribution line carrier systems - Part 5-1: Lower layer profiles - The spread frequency shift keying (S-FSK) profile |
EN 62056-3-1:2014 | Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling |
ISO/IEC/IEEE 60559:2011 | Information technology — Microprocessor Systems — Floating-Point arithmetic |
EN 61334-4-511:2000 | Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol |
IEC 61334-4-511:2000 | Distribution automation using distribution line carrier systems - Part 4-511: Data communication protocols - Systems management - CIASE protocol |
EN 62056-21:2002 | Electricity metering - Data exchange for meter reading, tariff and load control - Part 21: Direct local data exchange |
IEC 61334-6:2000 | Distribution automation using distribution line carrier systems - Part 6: A-XDR encoding rule |
EN 13757-5:2015 | Communication systems for meters - Part 5: Wireless M-Bus relaying |
IEC 62056-5-3:2017 | Electrcity metering data exchange - The DLMS/COSEM suite - Part 5-3: DLMS/COSEM application layer |
EN 62056-8-3:2013 | Electricity metering data exchange - The DLMS/COSEM suite - Part 8-3: Communication profile for PLC S-FSK neighbourhood networks |
IEC 62056-21:2002 | Electricity metering - Data exchange for meter reading, tariff and load control - Part 21: Direct local data exchange |
EN 13757-4:2013 | Communication systems for meters and remote reading of meters - Part 4: Wireless meter readout (Radio meter reading for operation in SRD bands) |
IEC TR 62051-1:2004 | Electricity metering - Data exchange for meter reading, tariff and load control - Glossary of terms - Part 1: Terms related to data exchange with metering equipment using DLMS/COSEM |
ISO 4217:2015 | Codes for the representation of currencies |
EN 62056-8-6:2017 | Electricity metering data exchange - The DLMS/COSEM suite - Part 8-6: High speed PLC ISO/IEC 12139-1 profile for neighbourhood networks |
EN 61334-5-1:2001 | Distribution automation using distribution line carrier systems - Part 5-1: Lower layer profiles - The spread frequency shift keying (S-FSK) profile |
EN 62056-5-3:2017 | Electricity metering data exchange - The DLMS/COSEM suite - Part 5-3: DLMS/COSEM application layer |
IEC 61334-4-41:1996 | Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 41: Application protocol - Distribution line message specification |
IEC 62056-7-6:2013 | Electricity metering data exchange - The DLMS/COSEM suite - Part 7-6: The 3-layer, connection-oriented HDLC based communication profile |
IEC 62056-9-7:2013 | Electricity metering data exchange - The DLMS/COSEM suite - Part 9-7: Communication profile for TCP-UDP/IP networks |
EN 61334-4-32:1996 | Distribution automation using distribution line carrier systems - Part 4: Data communication protocols - Section 32: Data link layer - Logical link control (LLC) |
IEC 62056-8-3:2013 | Electricity metering data exchange - The DLMS/COSEM suite - Part 8-3: Communication profile for PLC S-FSK neighbourhood networks |
IEC 62056-31:1999 | Electricity metering - Data exchange for meter reading, tariff and load control - Part 31: Use of local area networks on twisted pair with carrier signalling |
IEC 62056-3-1:2013 | Electricity metering data exchange - The DLMS/COSEM suite - Part 3-1: Use of local area networks on twisted pair with carrier signalling |
IEC 62056-6-1:2017 | Electricity metering data exchange - The DLMS/COSEM suite - Part 6-1: Object Identification System (OBIS) |
IEC 62056-46:2002+AMD1:2006 CSV | Electricity metering - Data exchange for meter reading, tariff and load control - Part 46: Data link layer using HDLC protocol |
ISO/IEC 8802-2:1998 | Information technology — Telecommunications and information exchange between systems — Local and metropolitan area networks — Specific requirements — Part 2: Logical link control |
IEC 62056-4-7:2015 | Electricity metering data exchange - The DLMS/COSEM suite - Part 4-7: DLMS/COSEM transport layer for IP networks |
ANSI C12.19 : 2012 | UTILITY INDUSTRY END DEVICE DATA TABLES |
EN 13757-1:2014 | Communication systems for meters - Part 1: Data exchange |
ISO/IEC 12139-1:2009 | Information technology Telecommunications and information exchange between systems Powerline communication (PLC) High speed PLC medium access control (MAC) and physical layer (PHY) Part 1: General requirements |
IEC 61334-4-512:2001 | Distribution automation using distribution line carrier systems - Part 4-512: Data communication protocols - System management using profile 61334-5-1 - Management Information Base (MIB) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.