I.S. EN 62209-2:2010

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

HUMAN EXPOSURE TO RADIO FREQUENCY FIELDS FROM HAND-HELD AND BODYMOUNTED WIRELESS COMMUNICATION DEVICES - HUMAN MODELS, INSTRUMENTATION, AND PROCEDURES - PART 2: PROCEDURE TO DETERMINE THE SPECIFIC ABSORPTION RATE (SAR) FOR WIRELESS COMMUNICATION DEVICES USED IN CLOSE PROXIMITY TO THE HUMAN BODY (FREQUENCY RANGE OF 30 MHZ TO 6 GHZ)

Available format(s)

Hardcopy , PDF

Superseded date

07-24-2019

Language(s)

English

Published date

01-01-2010

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

US$166.05
Excluding Tax where applicable

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Measurement system specifications
6 Protocol for SAR evaluation
7 Uncertainty estimation
8 Measurement report
Annex A (informative) - Phantom rationale
Annex B (normative) - SAR measurement system verification
Annex C (informative) - Fast SAR testing
Annex D (informative) - Standard sources and phantoms
        for system validation
Annex E (informative) - Example recipes for phantom
        tissue-equivalent liquids
Annex F (normative) - SAR correction for deviations of
        complex permittivity from targets
Annex G (informative) - Hands-free kit testing
Annex H (informative) - Skin enhancement factor
Annex I (informative) - Tissue-equivalent liquid dielectric
        property measurements and measurement uncertainty
        estimation
Annex J (informative) - Testing compliance for the exposure
        of the hand
Annex K (informative) - Test reduction
Annex L (normative) - Power scaling procedure
Annex M (informative) - Rationale for probe parameters
Bibliography
Annex ZA (normative) - Normative references to international
         publications with their corresponding European
         publications

Pertains to any wireless communication device capable of transmitting electromagnetic fields (EMF) intended to be used at a position near the human body, in the manner described by the manufacturer, with the radiating part(s) of the device at distances up to and including 200 mm from a human body, i.e. when held in the hand or in front of the face, mounted on the body, combined with other transmitting or non-transmitting devices or accessories (e.g. belt-clip, camera or Bluetooth add-on), or embedded in garments.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
118
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

Standards Relationship
IEC 62209-2:2010 Identical
EN 62209-2:2010 Identical

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
IEC 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
IEC 62479:2010 Assessment of the compliance of low-power electronic and electrical equipment with the basic restrictions related to human exposure to electromagnetic fields (10 MHz to 300 GHz)
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
ISO/IEC Guide 51:2014 Safety aspects — Guidelines for their inclusion in standards
IEEE 1528-2013 REDLINE IEEE Recommended Practice for Determining the Peak Spatial-Average Specific Absorption Rate (SAR) in the Human Head from Wireless Communications Devices: Measurement Techniques
IEC 62311:2007 Assessment of electronic and electrical equipment related to human exposure restrictions for electromagnetic fields (0 Hz - 300 GHz)
ISO 10012:2003 Measurement management systems — Requirements for measurement processes and measuring equipment
EN 62209-1:2016 Measurement procedure for the assessment of specific absorption rate of human exposure to radio frequency fields from hand-held and body-mounted wireless communication devices - Part 1: Devices used next to the ear (Frequency range of 300 MHz to 6 GHz)
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.