I.S. EN 62019:2000
Current
The latest, up-to-date edition.
ELECTRICAL ACCESSORIES - CIRCUIT-BREAKERS AND SIMILAR EQUIPMENT FOR HOUSEHOLD USE - AUXILIARY CONTACT UNITS
Hardcopy , PDF
English
01-01-2000
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
1 Scope and object
2 Normative references
3 Definitions
4 Classification
5 Characteristics
6 Marking and other information
7 Standard conditions for operation in service
8 Requirements for construction and operation
9 Tests
Annex A (normative) - Determination of clearances and creepage
distances
Annex B (informative) - Contact rating based on utilization
categories
Annex C (informative) - Example of inductive loads for tests of
d.c. contacts
Annex D (informative) - Bibliography
Annex ZA (normative) - Normative references to international
publications with their corresponding European
publications
Pertains to auxiliary electromechanical contact units associated (or intended to be associated) with circuit-breakers for overcurrent protection, and with residual current operated circuit-breakers with or without integral overcurrent protection for household and similar installations, having a rated voltage not exceeding 440 V a.c. and 250 V d.c., and a rated current not exceeding 10 A.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
108
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
EN 62019:1999/A12:2014 | Identical |
BS EN 62019:1999+A12:2014 | Identical |
SN EN 62019 : 1999 AMD 11 2005 | Identical |
DIN EN 62019 : 2015 | Identical |
NBN EN 62019 : 2000 AMD 3 2015 | Identical |
NF EN 62019 : 99 AMD 12 2015 | Identical |
UNE-EN 62019:2001 | Identical |
IEC 60947-5-4:2002 | Low-voltage switchgear and controlgear - Part 5-4: Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests |
IEC 60112:2003+AMD1:2009 CSV | Method for the determination of the proof and the comparative tracking indices of solid insulating materials |
EN 60998-2-2:2004 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
IEC 60384-14:2013+AMD1:2016 CSV | Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains |
IEC 60898:1995 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations |
HD 214 : 200S2 | RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS |
EN 60065:2014/AC:2017-01 | AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016) |
IEC 60050-441:1984 | International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses |
IEC 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 61008-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers without integral overcurrent protection for household and similar uses (RCCBs) - Part1: General rules |
EN 60947-5-4:2003 | Low-voltage switchgear and controlgear - Part 5-4: Control circuit devices and switching elements - Method of assessing the performance of low-energy contacts - Special tests |
IEC 61009-1:2010+AMD1:2012+AMD2:2013 CSV | Residual current operated circuit-breakers with integral overcurrentprotection for household and similar uses (RCBOs) - Part 1: General rules |
IEC 60998-2-2:2002 | Connecting devices for low-voltage circuits for household and similar purposes - Part 2-2: Particular requirements for connecting devices as separate entities with screwless-type clamping units |
ISO 306:2013 | Plastics — Thermoplastic materials — Determination of Vicat softening temperature (VST) |
EN 61210:2010 | Connecting devices - Flat quick-connect terminations for electrical copper conductors - Safety requirements |
IEC 60664-3:2016 | Insulation coordination for equipment within low-voltage systems - Part 3: Use of coating, potting or moulding for protection against pollution |
HD 625.3 : 200S1 | INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PART 3: USE OF COATINGS TO ACHIEVE INSULATION COORDINATION OF PRINTED BOARD ASSEMBLIES |
IEC 60445:2017 | Basic and safety principles for man-machine interface, marking and identification - Identification of equipment terminals, conductor terminations and conductors |
IEC 60664-1:2007 | Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests |
EN ISO 306:2013 | Plastics - Thermoplastic materials - Determination of Vicat softening temperature (VST) (ISO 306:2013) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.