I.S. EN 61967-4:2002
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
INTEGRATED CIRCUITS - MEASUREMENT OF ELECTROMAGNETIC EMISSIONS, 150 KHZ TO 1 GHZ - PART 4: MEASUREMENT OF CONDUCTED EMISSIONS - 1 OHM/150 OHM DIRECT COUPLING METHOD
Hardcopy , PDF
05-21-2021
English
01-01-2002
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
National Foreword
FOREWORD
1 Scope
2 Normative references
3 Definitions
4 General
5 Test conditions
6 Test equipment
7 Test set-up
8 Test procedure
9 Test report
Annex A (normative) Probe calibration procedure
Annex B (informative) Classification of conducted
emission levels
Annex C (informative) Example of reference levels for
automotive applications
Annex D (informative) EMC requirements and how to use
EMC IC measurement techniques
Annex E (informative) Example of a test set-up consisting of
an EMC main test board and an EMC
IC test board
Annex F (informative) 150 ohms direct coupling networks for
common mode emission measurements of differential
mode data transfer ICs and similar circuits
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Provides a method to measure the conducted electromagnetic emission of integrated circuits by direct RF current measurement with a 1 ohm resistive probe and RF voltage measurement using a 150 ohm coupling network. These methods guarantee a high degree of repeatability and correlation of measurements.
DevelopmentNote |
AMD 1 2006 Re-issued on 02.03.2007 and incorporates corrigendum 2006. (03/2007) For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
146
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
DIN EN 61967-4:2006-07 | Identical |
NF EN 61967-4 : 2002 AMD 1 2006 | Identical |
BS EN 61967-4 : 2002 | Identical |
NBN EN 61967-4 : 2003 AMD 1 2007 | Identical |
SN EN 61967-4 : AMD 1 2006 | Identical |
EN 61967-4 : 2002 COR 2017 | Identical |
IEC 61967-4:2002+AMD1:2006 CSV | Identical |
EN 55016-1-4:2010/A2:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-4: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNAS AND TEST SITES FOR RADIATED DISTURBANCE MEASUREMENTS (CISPR 16-1-4:2010/A2:2017) |
IEC 61967-1:2002 | Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions |
CISPR 16-1-4:2010+AMD1:2012+AMD2:2017 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-4: Radio disturbance and immunity measuring apparatus - Antennas and test sites for radiated disturbance measurements |
CISPR 16-1-1:2015 | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-1: Radio disturbance and immunity measuring apparatus - Measuring apparatus |
CISPR 16-1-3:2004+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-3: Radio disturbance and immunity measuring apparatus - Ancillary equipment - Disturbance power |
CISPR 16-1-5:2014+AMD1:2016 CSV | Specification for radio disturbance and immunity measuring apparatus and methods - Part 1-5: Radio disturbance and immunity measuring apparatus - Antenna calibration sites and reference test sites for 5 MHz to 18 GHz |
EN 61967-1:2002 | Integrated circuits - Measurement of electromagnetic emissions, 150 kHz to 1 GHz - Part 1: General conditions and definitions |
IEC 61000-4-6:2013 | Electromagnetic compatibility (EMC) - Part 4-6: Testing and measurement techniques - Immunity to conducted disturbances, induced by radio-frequency fields |
EN 55016-1-5:2015/A1:2017 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-5: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANTENNA CALIBRATION SITES AND REFERENCE TEST SITES FOR 5 MHZ TO 18 GHZ (CISPR 16-1-5:2014/A1:2016) |
EN 55016-1-3:2006/A1:2016 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-3: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - ANCILLARY EQUIPMENT - DISTURBANCE POWER (CISPR 16-1-3:2004) |
EN 61000-4-6:2014/AC:2015 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013) |
EN 55016-1-1:2010/A2:2014 | SPECIFICATION FOR RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS AND METHODS - PART 1-1: RADIO DISTURBANCE AND IMMUNITY MEASURING APPARATUS - MEASURING APPARATUS (CISPR 16-1-1:2010/A2:2014) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.