I.S. EN 60707:1999
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
FLAMMABILITY OF SOLID NON-METALLIC MATERIALS WHEN EXPOSED TO FLAME SOURCES - LIST OF TEST METHODS
Hardcopy , PDF
06-09-2016
English
11-12-1999
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
4 Test methods
5 Requirements and classification
Annex ZA (normative) Normative references to international
publications with their corresponding
European publications
Bibliography
Gives test methods applicable to solid non-metallic materials having an apparent density of not less than 250 kg/m[3], determined in accordance with ISO 845, and intended to serve as a preliminary indication of the behaviour of these materials when exposed to a flame ignition source.
DocumentType |
Standard
|
Pages |
30
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Withdrawn
|
Standards | Relationship |
SN EN 60707 : 1999 | Identical |
UNE-EN 60707:2000 | Identical |
NBN EN 60707 : 1ED 2000 | Identical |
NF EN 60707 : 2000 | Identical |
DIN EN 60707 : 1999 | Identical |
EN 60707 : 1999 | Identical |
BS EN 60707:1999 | Identical |
IEC 60707:1999 | Identical |
IEC 60695-11-20:2015 | Fire hazard testing - Part 11-20: Test flames - 500 W flame test method |
IEC 60695-1-3:1986 | Fire hazard testing. Part 1: Guidance for the preparation of requirements and test specifications for assessing fire hazard of electrotechnical products. Guidance for use of preselection procedures |
IEC 60695-1-1:1999 | Fire hazard testing - Part 1-1: Guidance for assessing the fire hazard of electrotechnical products - General guidelines |
IEC 60695-4:2012 | Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products |
ISO 845:2006 | Cellular plastics and rubbers — Determination of apparent density |
ISO 9773:1998 | Plastics — Determination of burning behaviour of thin flexible vertical specimens in contact with a small-flame ignition source |
ISO/IEC Guide 51:2014 | Safety aspects — Guidelines for their inclusion in standards |
ISO 9772:2012 | Cellular plastics Determination of horizontal burning characteristics of small specimens subjected to a small flame |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
IEC 60695-11-10:2013 | Fire hazard testing - Part 11-10: Test flames - 50 W horizontal and vertical flame test methods |
IEC TS 60695-11-3:2004 | Fire hazard testing - Part 11-3: Test flames - 500 W flames - Apparatus and confirmational test methods |
IEC TS 60695-11-4:2004 | Fire hazard testing - Part 11-4: Test flames - 50 W flame - Apparatus and confirmational test method |