I.S. EN 60601-2-36:2015
Current
The latest, up-to-date edition.
MEDICAL ELECTRICAL EQUIPMENT - PART 2-36: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF EQUIPMENT FOR EXTRACORPOREALLY INDUCED LITHOTRIPSY
Hardcopy , PDF
English
01-01-2015
For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.
Only cited Standards give presumption of conformance to New Approach Directives/Regulations.
FOREWORD
INTRODUCTION
201.1 Scope, object and related standards
201.2 Normative references
201.3 Terms and definitions
201.4 General requirements
201.5 General requirements for testing ME
EQUIPMENT
201.6 Classification of ME EQUIPMENT and
ME SYSTEMS
201.7 ME EQUIPMENT identification, marking
and documents
201.8 Protection against electrical HAZARDS from
ME EQUIPMENT
201.9 Protection against MECHANICAL HAZARDS
OF ME EQUIPMENT and ME SYSTEMS
201.10 Protection against unwanted and excessive
radiation HAZARDS
201.11 Protection against excessive temperatures
and other HAZARDS
201.12 Accuracy of controls and instruments and
protection against hazardous outputs
201.13 HAZARDOUS SITUATIONS and fault
conditions for ME EQUIPMENT
201.14 PROGRAMMABLE ELECTRICAL MEDICAL
SYSTEMS (PEMS)
201.15 Construction of ME EQUIPMENT
201.16 ME SYSTEMS
201.17 ELECTROMAGNETIC COMPATIBILITY
of ME EQUIPMENT and ME SYSTEMS
202 ELECTROMAGNETIC COMPATIBILITY - Requirements
and tests
Annexes
Annex AA (informative) - Particular guidance and rationale
Annex BB (informative) - Definition of coordinates, FOCUS
and TARGET LOCATION
Bibliography
Index of defined terms used in this particular standard
Annex ZA (normative) - Normative references to
international publications with their
corresponding European publications
Annex ZZ (informative) - Coverage of Essential
Requirements of EU Directives
Pertains to BASIC SAFETY and ESSENTIAL PERFORMANCE of equipment for EXTRACORPOREALLY INDUCED LITHOTRIPSY as defined in 201.3.206 including equipment for other medical applications of therapeutic extracorporeally induced focused PRESSURE PULSES, hereafter referred to as ME EQUIPMENT.
DevelopmentNote |
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
|
DocumentType |
Standard
|
Pages |
54
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Current
|
Standards | Relationship |
DIN EN 60601-2-36 : 2015 | Identical |
EN 60601-2-36:2015 | Identical |
SN EN 60601-2-36 : 1997 | Identical |
BS EN 60601-2-36:2015 | Identical |
UNE-EN 60601-2-36:1998 | Identical |
EN 10002-1 : 2001 | METALLIC MATERIALS - TENSILE TESTING - PART 1: METHOD OF TEST AT AMBIENT TEMPERATURE |
IEC 60601-2-5:2009 | Medical electrical equipment - Part 2-5: Particular requirements for the basic safety and essential performance of ultrasonic physiotherapy equipment |
IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
IEC 61689:2013 | Ultrasonics - Physiotherapy systems - Field specifications and methods of measurement in the frequency range 0,5 MHz to 5 MHz |
IEC 61846:1998 | Ultrasonics - Pressure pulse lithotripters - Characteristics of fields |
IEC 62555:2013 | Ultrasonics - Power measurement - High intensity therapeutic ultrasound (HITU) transducers and systems |
EN 61846:1998 | Ultrasonics - Pressure pulse lithotripters - Characteristics of fields |
IEC 60601-2-62:2013 | Medical electrical equipment - Part 2-62: Particular requirements for the basic safety and essential performance of high intensity therapeutic ultrasound (HITU) equipment |
IEC 60601-1-2:2014 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
EN 60601-1-2:2015 | Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral Standard: Electromagnetic disturbances - Requirements and tests |
DIN 50100:2015-11 (Draft) | LOAD CONTROLLED FATIGUE TESTING - EXECUTION AND EVALUATION OF CYCLIC TESTS AT CONSTANT LOAD AMPLITUDES ON METALLIC SPECIMENS AND COMPONENTS |
IEC TS 62556:2014 | Ultrasonics - Field characterization - Specification and measurement of field parameters for high intensity therapeutic ultrasound (HITU) transducers and systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.