• Shopping Cart
    There are no items in your cart

I.S. EN 54-30:2015

Current

Current

The latest, up-to-date edition.

FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 30: MULTI-SENSOR FIRE DETECTORS - POINT DETECTORS USING A COMBINATION OF CARBON MONOXIDE AND HEAT SENSORS

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2015

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

US$138.19
Excluding Tax where applicable

Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and abbreviations
4 Requirements
5 Test and evaluation methods
6 Assessment and verification of constancy of performance
  (AVCP)
7 Classification
8 Marking, labelling and packaging
Annex A (normative) - Gas test chamber for CO response
        value and cross-sensitivity to chemical agents
Annex B (normative) - Fire test room
Annex C (normative) - Measuring instruments for smoke and
        CO
Annex D (informative) - Establishing exposure levels of
        chemical agents
Annex E (normative) - Heat tunnel for heat response value
Annex F (normative) - Smouldering (pyrolysis) wood fire
        (TF2)
Annex G (normative) - Glowing smouldering cotton fire (TF3)
Annex H (normative) - Open plastics (polyurethane) fire
        (TF4)
Annex I (normative) - Liquid (heptane) fire (TF5)
Annex J (informative) - Information concerning the
        construction of the gas test chamber
Annex K (informative) - Construction of the heat tunnel
Annex L (informative) - Apparatus for impact test
Annex ZA (informative) - Clauses of this European Standard
         addressing the provisions of the EU Construction
         Products Regulation
Bibliography

Defines requirements, test methods and performance criteria for point-type multi-sensor fire detectors for use in fire detection systems installed in and around buildings, incorporating in one mechanical enclosure at least one carbon monoxide sensor and at least one heat sensor and where the overall fire detection performance is determined utilizing the combination of the detected phenomena.

DocumentType
Standard
Pages
100
PublisherName
National Standards Authority of Ireland
Status
Current

Standards Relationship
EN 54-30:2015 Identical

ISO 209:2007 Aluminium and aluminium alloys — Chemical composition
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
IEC 60068-2-27:2008 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 54-5:2017 Fire detection and fire alarm systems - Part 5: Heat detectors - Point heat detectors
EN 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
EN 54-26:2015 Fire detection and fire alarm systems - Part 26: Carbon monoxide detectors - Point detectors
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
IEC 60068-2-42:2003 Environmental testing - Part 2-42: Tests - Test Kc: Sulphur dioxide test for contacts and connections
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60068-2-30:2005 Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.