I.S. EN 54-2:1999

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-1999

Superseded date

06-12-2025

US$128.40
Excluding Tax where applicable

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

Foreword
Introduction
1 Scope
2 Normative references
3 Definitions and abbreviations
4 General requirements
5 General requirements for indications
6 The quiescent condition
7 The fire alarm condition
8 Fault warning condition
9 Disabled condition
10 Test condition (option with requirements)
11 Standardized input/output interface
12 Design requirements
13 Additional design requirements for software controlled
   control and indicating equipments
14 Marking
15 Tests
Annexes
A (informative) - Explanation of access levels
B (informative) - Optional functions with requirements
   and alternatives
C (informative) - Processing of signals from fire detectors
D (informative) - Explanation of zones and the zonal indication
   of fire alarms
E (informative) - Delays to outputs
F (informative) - Fault recognition and indication
G (informative) - Standardized input/output interface
   for the connection of ancillary equipment
   (e.g. a fire brigade panel)
H (informative) - Integrity of transmission paths
I (informative) - Design requirements for software
   controlled control and indicating equipments
ZA (informative) - Clauses addressing the provisions of the EU
   Construction Products Directive (89/106/EEC)
Bibliography

Defines requirements, test procedures and performance criteria for control and indicating equipment to be used in fire detecting and fire alarm systems installed in buildings.

DocumentType
Standard
Pages
110
PublisherName
National Standards Authority of Ireland
Status
Superseded
SupersededBy

I.S. 3218:2013 FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - SYSTEM DESIGN, INSTALLATION, COMMISSIONING, SERVICING AND MAINTENANCE

ENV 50142 : 1994 ELECTROMAGNETIC COMPATIBILITY - BASIC IMMUNITY STANDARD - SURGE IMMUNITY TESTS
EN 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
EN 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 60068-1:2014 Environmental testing - Part 1: General and guidance
IEC 60801-4:1988 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 4: Electrical fast transient/burst requirements
IEC 60817:1984 Spring-operated impact-test apparatus and its calibration
IEC 60068-2-47:2005 Environmental testing - Part 2-47: Test - Mounting of specimens for vibration, impact and similar dynamic tests
IEC 60068-2-3:1969 Basic environmental testing procedures - Part 2-3: Tests - Test Ca: Damp heat, steady state
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60068-2-2:2007 Environmental testing - Part 2-2: Tests - Test B: Dry heat
ISO 9001:2015 Quality management systems — Requirements
EN 60068-2-78:2013 Environmental testing - Part 2-78: Tests - Test Cab: Damp heat, steady state
IEC 60801-3:1984 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 3: Radiated electromagnetic field requirements
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
IEC 60068-2-75:2014 Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests
IEC 60068-2-1:2007 Environmental testing - Part 2-1: Tests - Test A: Cold
EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 54-1:2011 Fire detection and fire alarm systems - Part 1: Introduction
IEC 60801-2:1991 Electromagnetic compatibility for industrial-process measurement and control equipment - Part 2: Electrostatic discharge requirements
EN 60068-2-47:2005 Environmental testing - Part 2-47: Tests - Mounting of specimens for vibration, impact and similar dynamic tests
EN 60721-3-3 : 95 AMD 2 97 CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - CLASSIFICATION OF GROUPS OF ENVIRONMENTAL PARAMETERS AND THEIR SEVERITIES - STATIONARY USE AT WEATHER-PROTECTED LOCATIONS

Access your standards online with a subscription

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.

US$128.40
Excluding Tax where applicable