• Shopping Cart
    There are no items in your cart

I.S. EN 50289-4-11:2002

Current

Current

The latest, up-to-date edition.

COMMUNICATION CABLES - SPECIFICATIONS FOR TEST METHODS - PART 4-11: ENVIRONMENTAL TEST METHODS - A HORIZONTAL INTEGRATED FIRE TEST METHOD

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2002

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

US$71.32
Excluding Tax where applicable

1 Scope
2 Normative references
3 Definitions, symbols and abbreviations
4 Test environment
5 Test apparatus
   5.1 Air-inlet chamber
   5.2 Air-inlet shutter
   5.3 Fire-test chamber
   5.4 Gas burner
   5.5 Removable top cover
   5.6 Exhaust transition
   5.7 Exhaust duct
   5.8 Exhaust duct velocity measurement system
   5.9 Smoke measurement system
   5.10 Smoke release rate measurement system
   5.11 Exhaust duct damper
   5.12 Exhaust blower
   5.13 Fire-test chamber airflow system
   5.14 Ladder cable tray
   5.15 Fire-test chamber temperature measurement
        instruments
   5.16 Data acquisition equipment
   5.17 Heat release rate measurement system
6 Test specimens
7 Calibration and maintenance of test equipment
   7.1 Maintenance
   7.2 Frequency of calibration
   7.3 Airflow
        7.3.1 Air leakage test
        7.3.2 Supplemental air leakage test
        7.3.3 Velocity traverse test
   7.4 Smoke measurement system calibration test
   7.5 Fuel
   7.6 Reinforced inorganic cement board test
        7.6.1 Temperature preheat
        7.6.2 Temperature history test
   7.7 Standard insulated conductor test
   7.8 Procedures for calibration of heat release rate
        measurement equipment
        7.8.1 Analyser calibration
        7.8.2 Delay time
        7.8.3 Calibration test
8 Test specimen preparation
   8.1 Specimen conditioning
   8.2 Determination of specimen diameter
   8.3 Number of cable lengths
   8.4 Cable mounting
9 Test procedures
   9.1 Flame propagation distance and smoke measurement
        test procedure
   9.2 Heat release test procedure
   9.3 Time-to-ignition test procedure
   9.4 Flaming droplets/particles test procedure
10 Post-test clean-up and inspection
   10.1 Smoke measurement system post-test procedure
   10.2 Heat release rate post-test procedure
11 Calculations
   11.1 Optical density of smoke
   11.2 Smoke release rate calculation
   11.3 Exhaust duct velocity measurement calculations
   11.4 Exhaust duct volumetric flow rate calculations
   11.5 Heat release rate calculations
        11.5.1 Peak heat release rate
        11.5.2 Total heat released
   11.6 Time-to-ignition calculations
   11.7 Flaming droplets/particles calculations
12 Report
Annex A (normative) Method for determining suitability of
                      oxygen analysers for making heat release
                      measurements
Annex B (informative) Material information list
Annex C (informative) Brick sizes and locations

Specifies a horizontal integrated fire test method for determining flame-propagation distance, optical smoke density, total heat release, heat release rate, time to ignition and flaming droplets/particles for communication cables.

DocumentType
Standard
Pages
66
PublisherName
National Standards Authority of Ireland
Status
Current

IEC 60695-4:2012 Fire hazard testing - Part 4: Terminology concerning fire tests for electrotechnical products
EN 60695-4:2012 FIRE HAZARD TESTING - PART 4: TERMINOLOGY CONCERNING FIRE TESTS FOR ELECTROTECHNICAL PRODUCTS (IEC 60695-4:2012)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.