I.S. EN 14897:2006

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

WATER CONDITIONING EQUIPMENT INSIDE BUILDINGS - DEVICES USING MERCURY LOW-PRESSURE ULTRAVIOLET RADIATORS - REQUIREMENTS FOR PERFORMANCE, SAFETY AND TESTING

Available format(s)

Hardcopy , PDF

Withdrawn date

07-11-2007

Language(s)

English

Published date

08-04-2006

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

US$71.32
Excluding Tax where applicable

Foreword
1 Scope
2 Normative references
3 Definitions
4 Requirements
  4.1 General
  4.2 Radiation chamber
  4.3 Low-pressure mercury UV lamps
  4.4 Electrical
      4.4.1 General
      4.4.2 UV disinfection devices
      4.4.3 UV bactericidal treatment devices
  4.5 Performance
  4.6 Labelling
  4.7 Manual
5 Testing
  5.1 General
  5.2 Test rig and installation
  5.3 Biodosimetric measurements
  5.4 Performance test procedure
      5.4.1 UV disinfection devices
      5.4.2 Processing of the data
      5.4.3 UV bactericidal treatment devices
      5.4.4 Processing of the data
Annex A (normative) Requirements for the device sensor
      A.1 Calibration
      A.2 Selectivity
      A.3 Measuring range linearity
      A.4 Measuring range and resolution
      A.5 Temperature drift
      A.6 Stability over time
Annex B (normative) Biodosimeter calibration
Annex C (informative) Monitoring window
Annex D (normative) Manufacturer's information for the type test
Annex E (normative) Manufacturer's information for the UV device user
Annex F (normative) Installation, operation and maintenance
Bibliography

Describes definitions, principles of construction, requirements and methods for testing the performance of UV devices for drinking water installations inside buildings which are permanently connected to the mains supply at the point of entry into a building or within the water distribution system inside the building.

DevelopmentNote
2006 Edition Re-Issued in July 2007 & incorporates AMD 1 2007. (07/2007)
DocumentType
Standard
Pages
32
PublisherName
National Standards Authority of Ireland
Status
Withdrawn

EN 15161:2006 Water conditioning equipment inside buildings - Installation, operation, maintenance and repair
EN 1717:2000 Protection against pollution of potable water in water installations and general requirements of devices to prevent pollution by backflow
DVGW W 294 : 1997 UV-SYSTEMS FOR DISINFECTION OF DRINKING WATER SUPPLIES - REQUIREMENTS AND TESTING
ONORM M 5873-1 : 2001 PLANTS FOR THE DISINFECTION OF WATER USING ULTRAVIOLET RADIATION - REQUIREMENTS AND TESTING - LOW PRESSURE MERCURY LAMP PLANTS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.