AMBIENT AIR - STANDARD METHOD FOR THE MEASUREMENT OF THE CONCENTRATION OF SULPHUR DIOXIDE BY ULTRAVIOLET FLUORESCENCE

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

09-04-2012

Preview

For Harmonized Standards, check the EU site to confirm that the Standard is cited in the Official Journal.

Only cited Standards give presumption of conformance to New Approach Directives/Regulations.

US$154.91
Excluding Tax where applicable

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Abbreviated terms
5 Principle
6 Sampling
7 Analyser equipment
8 Type approval of ultraviolet fluorescence sulphur
   dioxide analysers
9 Field operation and ongoing quality control
10 Expression of results
11 Test reports and documentation
Annex A (normative) - Test of lack of fit
Annex B (informative) - Sampling equipment
Annex C (informative) - Ultraviolet fluorescence analyser
Annex D (informative) - Manifold testing
Annex E (normative) - Type approval
Annex F (informative) - Calculation of uncertainty in field
        operation at the hourly limit value
Annex G (informative) - Calculation of uncertainty in field
        operation at the daily limit value
Annex H (informative) - Calculation of uncertainty in field
        operation at the annual critical level
Annex I (informative) - Significant technical changes
Bibliography

Defines a continuous measurement method for the determination of the concentration of sulphur dioxide present in ambient air based on the ultraviolet fluorescence measuring principle.

DocumentType
Standard
Pages
110
PublisherName
National Standards Authority of Ireland
Status
Current
Supersedes

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 6144:2003 Gas analysis — Preparation of calibration gas mixtures — Static volumetric method
EN ISO 6142:2006 Gas analysis - Preparation of calibration gas mixtures - Gravimetric method (ISO 6142:2001)
ISO 6145-7:2009 Gas analysis Preparation of calibration gas mixtures using dynamic volumetric methods Part 7: Thermal mass-flow controllers
ISO 14956:2002 Air quality — Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty
EN ISO 6145-7:2010 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 7: Thermal mass-flow controllers (ISO 6145-7:2009)
EN ISO 6143:2006 Gas analysis - Comparison methods for determining and checking the composition of calibration gas mixtures (ISO 6143:2001)
EN 15267-2:2009 Air quality - Certification of automated measuring systems - Part 2: Initial assessment of the AMS manufacturer’s quality management system and post certification surveillance for the manufacturing process
EN ISO 6145-10:2008 Gas analysis - Preparation of calibration gas mixtures using dynamic volumetric methods - Part 10: Permeation method (ISO 6145-10:2002)
ISO/IEC Guide 99:2007 International vocabulary of metrology Basic and general concepts and associated terms (VIM)
EN ISO 20988:2007 Air quality - Guidelines for estimating measurement uncertainty (ISO 20988:2007)
ISO 6143:2001 Gas analysis — Comparison methods for determining and checking the composition of calibration gas mixtures
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
EN ISO 14956:2002 Air quality - Evaluation of the suitability of a measurement procedure by comparison with a required measurement uncertainty (ISO 14956:2002)
ISO 6142:2001 Gas analysis Preparation of calibration gas mixtures Gravimetric method
ISO 6145-10:2002 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 10: Permeation method
ISO 9001:2015 Quality management systems — Requirements
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN ISO 6145-6:2017 Gas analysis - Preparation of calibration gas mixtures using dynamic methods - Part 6: Critical flow orifices (ISO 6145-6:2017)
ISO 20988:2007 Air quality Guidelines for estimating measurement uncertainty
ISO 6145-6:2017 Gas analysis — Preparation of calibration gas mixtures using dynamic methods — Part 6: Critical flow orifices
EN 15267-1:2009 Air quality - Certification of automated measuring systems - Part 1: General principles
EN ISO 6144:2006 Gas analysis - Preparation of calibration gas mixtures - Static volumetric method (ISO 6144:2003)

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.