I.S. 3218:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
FIRE DETECTION AND ALARM SYSTEMS FOR BUILDINGS - SYSTEM DESIGN, INSTALLATION, COMMISSIONING, SERVICING AND MAINTENANCE
Hardcopy , PDF
09-20-2019
English
01-01-2013
DECLARATION
1 Scope
2 Normative References
3 Terms and definitions
4 Transition arrangements from I.S. 3218:1989
& I.S. 3218:2009 to I.S. 3218:2013
5 System design: Overview
6 Design considerations
7 Limitation of false alarm(see definition)
8 Workmanship, installation and commissioning
9 User responsibilities
10 Fire alarm systems in residential buildings
Annex A (Informative) - Compatibility requirements
Annex B (Informative) - Automatic connection to the Alarm
Receiving Centre (ARC)
Annex C 1 (normative) - Fire detection and alarm
system - Certificate of Design
Annex C 2 (normative) - Fire detection and alarm
system - Certificate of Installation
Annex C 3 (normative) - Fire detection and alarm
system - Final Certificate of Commissioning
Annex C 4 (normative) - Fire detection and alarm
system - Certificate of commissioning for
modification, extension or alterations to a
system
Annex C 5 (normative) - Fire detection and alarm
system - Certificate of Commissioning
for early handover for beneficial use
Annex C 6 (normative) - Fire detection and alarm
system - Certificate for Handover
Annex C 7 (normative) - Fire detection and alarm
system - Certificate of Verification
Annex D 1 (normative) - Fire detection and alarm
system- Certificate of Servicing/Testing
Annex D 1 (normative) - Fire detection and alarm
system- Certificate of Servicing/Testing
Annex D .2 (normative) - Fire detection and alarm
system: schedule of servicing/testing
Annex E 1 (informative) - Model logbook for fire alarm
systems - Front page
Annex E 2 (informative) - Model logbook for fire alarm
systems - General register
Annex E 3 (informative) - Model logbook for fire alarm
systems - False alarm register
Annex F (normative) - Ionisation chamber smoke
detectors
Annex G (informative) - Fire alarm systems integrated
with other systems
Annex H (informative) - Responsibilities
Annex I (informative) - Guide to recommendations applicable
to specific types of premises
Annex J (Normative) - Guidance on layout of smoke/heat
alarms in dwelling houses, apartments or maisonettes
Annex K (normative) - Model certificate of design, installation
and commissioning of smoke/heat
alarm systems in dwellings
Annex L (normative) - Model certificate of servicing/testing
of a smoke/heat alarm system in dwellings
Annex M (Informative) - Staged (Phased) Fire Alarms
Bibliography
Gives requirements and recommendations for the planning, design, installation, commissioning, servicing and maintenance of fire detection and alarm systems in premises including those used for residential/domestic purposes.
DocumentType |
Standard
|
Pages |
156
|
PublisherName |
National Standards Authority of Ireland
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
CISPR 14-1:2016 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission |
I.S. EN 62305-3:2011 | PROTECTION AGAINST LIGHTNING - PART 3: PHYSICAL DAMAGE TO STRUCTURES AND LIFE HAZARD |
I.S. EN 54-5:2017 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 5: HEAT DETECTORS - POINT HEAT DETECTORS |
I.S. EN 54-12:2015 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 12: SMOKE DETECTORS - LINE DETECTORS USING AN OPTICAL BEAM |
I.S. EN 62305-2:2012 | PROTECTION AGAINST LIGHTNING - PART 2: RISK MANAGEMENT (IEC 62305-2:2010 (MOD)) |
BS 5446-3:2005 | Fire detection and fire alarm devices for dwellings Specification for smoke alarm kits for deaf and hard of hearing people |
I.S. EN ISO 9000:2015 | QUALITY MANAGEMENT SYSTEMS - FUNDAMENTALS AND VOCABULARY (ISO 9000:2015) |
I.S. EN 62305-4:2011 | PROTECTION AGAINST LIGHTNING - PART 4: ELECTRICAL AND ELECTRONIC SYSTEMS WITHIN STRUCTURES |
I.S. EN 54-25:2008 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 25: COMPONENTS USING RADIO LINKS |
BS 5839-1:2013 | Fire detection and fire alarm systems for buildings Code of practice for design, installation, commissioning and maintenance of systems in non-domestic premises |
CISPR 14-2:2015 RLV | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity - Product family standard |
I.S. EN 54-4:1998 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 4: POWER SUPPLY EQUIPMENT |
BS 6132:1983 | Code of practice for safe operation of alkaline secondary cells and batteries |
I.S. EN 54-7:2000 | COMPONENTS OF AUTOMATIC FIRE DETECTION SYSTEMS - POINT-TYPE SMOKE DETECTORS - DETECTORS USING SCATTERED LIGHT, TRANSMITTED LIGHT OR IONIZATION |
I.S. EN 14604:2005 | SMOKE ALARM DEVICES |
I.S. EN 54-20:2006 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 20: ASPIRATING SMOKE DETECTORS |
I.S. EN 54-11:2001 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 11: MANUAL CALL POINTS |
I.S. EN 54-13:2017 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 13: COMPATIBILITY AND CONNECTABILITY ASSESSMENT OF SYSTEM COMPONENTS |
I.S. EN 62305-1:2011 | PROTECTION AGAINST LIGHTNING - PART 1: GENERAL PRINCIPLES |
BS 5839-6:2004 | Fire detection and fire alarm systems for buildings Code of practice for the design, installation and maintenance of fire detection and fire alarm systems in dwellings |
I.S. EN 54-10:2002 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 10: FLAME DETECTORS - POINT DETECTORS |
I.S. EN 60849:1999 | SOUND SYSTEMS FOR EMERGENCY PURPOSES |
I.S. EN 50200:2015 | METHOD OF TEST FOR RESISTANCE TO FIRE OF UNPROTECTED SMALL CABLES FOR USE IN EMERGENCY CIRCUITS |
I.S. 3217:2013 | EMERGENCY LIGHTING |
I.S. EN 50272-1:2010 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 1: GENERAL SAFETY INFORMATION |
BS 5588-1:1990 | Fire precautions in the design, construction and use of buildings Code of practice for residential buildings |
I.S. EN 54-2:1999 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 2: CONTROL AND INDICATING EQUIPMENT |
BS 9991:2011 | Fire safety in the design, management and use of residential buildings. Code of practice |
I.S. EN 54-23:2010 | FIRE DETECTION AND FIRE ALARM SYSTEMS - PART 23: FIRE ALARM DEVICES - VISUAL ALARM DEVICES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.