HD 428.2.2 : 200S1
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
THREE-PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 2: DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH-VOLTAGE AND/OR LOW VOLTAGE SIDE - SECTION 2: CABLE BOXES TYPE 1 FOR USE ON DISTRIBUTION TRANSFORMERS MEETING THE REQUIREMENTS OF HD 428.2.1 S1
04-01-2007
01-12-2013
Foreword
1 Scope
2 Normative references
3 Definitions
4 Electrical requirements and clearances
5 Design considerations
6 Testing
7 Earthing of cable boxes
Defines the requirements for cable boxes, Type 1, in which the cable cores are terminated.
Committee |
TC 14
|
DocumentType |
Standard
|
PublisherName |
European Committee for Standards - Electrical
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
I.S. HD 428-2-2:1999 | Identical |
SN HD 428.2.2 : 200S1 | Identical |
BS 7821-2.2:1998 | Identical |
VDE 0532-222 : 1997 | Identical |
UNE 21428-2-2:2000 | Similar to |
DIN VDE 0532-222 : 1997 | Identical |
NEN HD 428-2-2 : 1997 | Identical |
CEI 14-21 : 1ED 1997 | Identical |
DIN VDE 0532-222 : 1997 | Corresponds |
CEI 20-62/2 : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
CEI 20-62/1 : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
BS 7888-4.1(2006) : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
03/315042 DC : DRAFT OCT 2003 | CENELEC HD 629.1 S2 - TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
HD 629.1 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
I.S. HD 629.1:2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3.6/6(7.2) KV UP TO 20.8/36(42) KV - PART 1: CABLES WITH EXTRUDED INSULATION |
BS 7821-1:1995 | Three phase oil-immersed distribution transformers, 50 Hz, from 50 to 2500 kVA with highest voltage for equipment not exceeding 36 kV General requirements and requirements for transformers with highest voltage for equipment not exceeding 24 kV |
03/315043 DC : DRAFT OCT 2003 | CENELEC HD 629.2 S2 - TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
I.S. HD 629-2:2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
HD 629.2 S2:2006/A1:2008 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
BS 7888-4.2(2006) : 2006 | TEST REQUIREMENTS ON ACCESSORIES FOR USE ON POWER CABLES OF RATED VOLTAGE FROM 3,6/6(7,2) KV UP TO 20,8/36(42) KV - PART 2: CABLES WITH IMPREGNATED PAPER INSULATION |
HD 607 : 200S1 | BUSBAR BUSHINGS UP TO 1 KV AND FROM 1,25 KA TO 5 KA, FOR LIQUID FILLED TRANSFORMERS |
HD 506 : S1 AMD 1 | |
EN 50180:2010 | Bushings above 1 kV up to 52 kV and from 250 A to 3,15 kA for liquid filled transformers – Part 1: General requirements for bushings |
HD 428.1 S1:1992/AC:2011 | THREE PHASE OIL-IMMERSED DISTRIBUTION TRANSFORMERS, 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - PART 1: GENERAL REQUIREMENTS AND REQUIREMENTS FOR TRANSFORMERS WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 24 KV |
HD 428.2.1 : 200S1 | THREE PHASE OIL IMMERSED DISTRIBUTION TRANSFORMERS 50 HZ, FROM 50 TO 2500 KVA WITH HIGHEST VOLTAGE FOR EQUIPMENT NOT EXCEEDING 36 KV - DISTRIBUTION TRANSFORMERS WITH CABLE BOXES ON THE HIGH VOLTAGE AND/OR LOW VOLTAGE SIDE - GENERAL REQUIREMENTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.