• Shopping Cart
    There are no items in your cart

ETS 300 200019-1-4 : 20001

Current

Current

The latest, up-to-date edition.

EQUIPMENT ENGINEERING (EE); ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - STATIONARY USE AT NON-WEATHERPROTECTED LOCATIONS

Available format(s)

Hardcopy , PDF

US$19.53
Excluding Tax where applicable

Foreword
1 Scope
2 Normative references
3 Definitions
4 Environmental class
4.1 Class 4.1: Non-weatherprotected locations
    Class 4.1E: Non-weatherprotected locations -
                extended
5 Environmental conditions
  5.1 Climatic conditions
  5.2 Biological conditions
  5.3 Chemically active substances
  5.4 Mechanically active substances
  5.5 Mechanical conditions
Annex A (informative):
History

Defines a class of environmental conditions and their severities to which equipment may be exposed. Includes only severe conditions that may be harmful to the equipment. Applies to equipment mounted for stationary use including periods of erection work, down time, maintenance and repair at non-weatherprotected locations.

Committee
EE 1
DocumentType
Standard
Pages
22
PublisherName
European Telecommunications Standards Institute
Status
Current
Supersedes

BS EN 62005-1:2001 Reliability of fibre optic interconnecting devices and passive optical components Introductory guide and definitions
I.S. EN 50378-3-1:2007 PASSIVE COMPONENTS TO BE USED IN OPTICAL FIBRE COMMUNICATION SYSTEMS - PRODUCT SPECIFICATIONS - PART 3-1: TYPE: 100/200 GHZ DWDM MODULE TERMINATED ON IEC 60793-2-50 CATEGORY B1.1 AND B1.3 SINGLE MODE FIBRE
TS 101 999 : 1.1.1 BROADBAND RADIO ACCESS NETWORKS (BRAN); HIPERACCESS; PHY PROTOCOL SPECIFICATION
TR 102 031-3 : 1.1.1 FIXED RADIO SYSTEMS; POINT-TO-POINT AND POINT-TO-MULTIPOINT EQUIPMENT; USE OF CIRCULAR POLARIZATION IN MULTIPOINT SYSTEMS; PART 3: ANTENNAS FOR MULTIPOINT FIXED RADIO SYSTEMS IN THE 1 GHZ TO 11 GHZ BAND
NF ETS 300019 1-0 : 1995 TELECOMMUNICATIONS - INGENIERIE DES EQUIPEMENTS (EE) - CONDITIONS ET ESSAIS D'ENVIRONNEMENT DES EQUIPEMENTS DE TELECOMMUNICATIONS - PARTIE 1-0: CLASSIFICATION DES CONDITIONS D'ENVIRONNEMENT - INTRODUCTION
IEC 61969-1:2011 Mechanical structures for electronic equipment - Outdoor enclosures - Part 1: Design guidelines
EN 60728-13:2010 Cable networks for television signals, sound signals and interactive services - Part 13: Optical systems for broadcast signal transmissions
BS EN 61969-1:2012 Mechanical structures for electronic equipment. Outdoor enclosures Design guidelines
TR 101 075 : 4.2.0 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2); BASE STATION AND ANCILLARY EQUIPMENT; PHYSICAL AND ELECTRICAL PARAMETERS; APPLICATION OF STANDARDS AND GUIDANCE NOTES (GSM 11.22 VERSION 4.2.0)
EN 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
ETSI GSM 05.05 : 050200 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+); RADIO TRANSMISSION AND RECEPTION
ETS 300 609-4 : 20004 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2 AND PHASE 2+) - BASE STATION SYSTEM (BSS) EQUIPMENT SPECIFICATION - PART 4: REPEATERS
CEI EN 60728-13 : 2010 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 13: OPTICAL SYSTEMS FOR BROADCAST SIGNAL TRANSMISSIONS
IEC 61709:2017 RLV Electric components - Reliability - Reference conditions for failure rates and stress models for conversion
TS 151 026 : 13.0.0 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+) (GSM); BASE STATION SYSTEM (BSS) EQUIPMENT SPECIFICATION; PART 4: REPEATERS (3GPP TS 51.026 VERSION 14.0.0 RELEASE 14)
EN 61969-1:2012 Mechanical structures for electronic equipment - Outdoor enclosures - Part 1: Design guidelines
EN 50378-3-1:2007 Passive components to be used in optical fibre communication systems - Product specifications - Part 3-1: Type: 100/200 GHz DWDM module terminated on IEC 60793-2-50 category B1.1 and B1.3 single mode fibre
BS EN 50378-3-1:2007 Passive components to be used in optical fibre communication systems. Product specifications Type 100/200 GHz DWDM module terminated on IEC 60793-2-50 category B1.1 and B1.3 single mode fibre
BS EN 61709:2017 Electric components. Reliability. Reference conditions for failure rates and stress models for conversion
CEI EN 61969-1 : 2012 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - OUTDOOR ENCLOSURES - PART 1: DESIGN GUIDELINES
I.S. EN 61969-1:2012 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - OUTDOOR ENCLOSURES - PART 1: DESIGN GUIDELINES (IEC 61969-1:2011 (EQV))
I.S. EN 61709:2017 ELECTRIC COMPONENTS - RELIABILITY - REFERENCE CONDITIONS FOR FAILURE RATES AND STRESS MODELS FOR CONVERSION
IEC 60728-13:2010 Cable networks for television signals, sound signals and interactive services - Part 13: Optical systems for broadcast signal transmissions
I.S. EN 60728-13:2010 CABLE NETWORKS FOR TELEVISION SIGNALS, SOUND SIGNALS AND INTERACTIVE SERVICES - PART 13: OPTICAL SYSTEMS FOR BROADCAST SIGNAL TRANSMISSIONS
BS EN 60728-13:2010 Cable networks for television signals, sound signals and interactive services Optical systems for broadcast signal transmissions
NF ETS 300019 2-0 : 1995 TELECOMMUNICATIONS - INGENIERIE DES EQUIPEMENTS (EE) - CONDITIONS ET ESSAIS D'ENVIRONNEMENT DES EQUIPEMENTS DE TELECOMMUNICATIONS - PARTIE 2-0: SPECIFICATIONS DES ESSAIS D'ENVIRONNEMENT - INTRODUCTION
ETS 300 910 : 20008 DIGITAL CELLULAR TELECOMMUNICATIONS SYSTEM (PHASE 2+) - RADIO TRANSMISSION AND RECEPTION
IEC 61709:2017 Electric components - Reliability - Reference conditions for failure rates and stress models for conversion

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.