EN ISO 9038:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Determination of sustained combustibility of liquids (ISO 9038:2013)
05-29-2021
07-17-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Apparatus
6 Preparation of apparatus
7 Sampling
8 Procedure
9 Assessment of results
10 Verification
11 Calculation of temperature adjustment
12 Precision
13 Test report
Annex A (normative) - Combustibility tester
Annex B (normative) - Apparatus verification
Bibliography
ISO 9038:2013 specifies a pass/fail procedure, at temperatures up to 100 °C, to determine whether or not a liquid product, that would be classified as "flammable" by virtue of its flash point, has the ability to sustain combustion at the temperature or temperatures specified in the appropriate regulations.The procedure is applicable to paints (including water-borne paints), varnishes, paint binders, solvents, petroleum or related products and adhesives, which have a flash point. It is not applicable to painted surfaces in respect of assessing their potential fire hazards.
Committee |
CEN/TC 139
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
UNE-EN ISO 9038:2004 | Identical |
IP 602 : 2014 | Identical |
NS EN ISO 9038 : 2013 | Identical |
ISO 9038:2013 | Identical |
SN EN ISO 9038:2013 | Identical |
NBN EN ISO 9038 : 2013 | Identical |
NEN EN ISO 9038 : 2013 | Identical |
UNE EN ISO 9038 : 2004 | Identical |
PN EN ISO 9038 : 2013 | Identical |
BS EN ISO 9038:2013 | Identical |
I.S. EN ISO 9038:2013 | Identical |
UNI EN ISO 9038 : 2013 | Identical |
DIN EN ISO 9038:2013-12 | Identical |
BS 2000-602(2013) : 2013 | Identical |
NF EN ISO 9038 : 2013 | Identical |
SS-EN ISO 9038:2013 | Identical |
ONORM EN ISO 9038 : 2013 | Identical |
UNE-EN ISO 9038:2014 | Identical |
DIN EN 16900 E : 2017 | FAST PYROLYSIS BIO-OILS FOR INDUSTRIAL BOILERS - REQUIREMENTS AND TEST METHODS |
PD CEN/TR 17103:2017 | Petroleum and related products. Fast pyrolysis bio-oils for stationary internal combustion engines. Quality determination |
S.R. CEN/TR 17103:2017 | FAST PYROLYSIS BIO-OILS FOR STATIONARY INTERNAL COMBUSTION ENGINES - QUALITY DETERMINATION |
CEN/TR 15138:2005 | Petroleum products and other liquids - Guide to flash point testing |
I.S. EN 16900:2017 | FAST PYROLYSIS BIO-OILS FOR INDUSTRIAL BOILERS - REQUIREMENTS AND TEST METHODS |
BS EN 16900:2017 | Fast pyrolysis bio-oils for industrial boilers. Requirements and test methods |
DIN EN 16900:2015-09 (Draft) | FAST PYROLYSIS BIO-OILS FOR INDUSTRIAL BOILERS - REQUIREMENTS AND TEST METHODS |
I.S. CEN/TR 15138:2005 | PETROLEUM PRODUCTS AND OTHER LIQUIDS - GUIDE TO FLASH POINT TESTING |
UNE-EN 16900:2017 | Fast pyrolysis bio-oils for industrial boilers - Requirements and test methods |
EN 16900:2017 | Fast pyrolysis bio-oils for industrial boilers - Requirements and test methods |
PD CEN/TR 15138:2005 | Petroleum products and other liquids. Guide to flash point testing |
15/30325842 DC : 0 | BS EN 16900 - FAST PYROLYSIS BIO-OILS FOR INDUSTRIAL BOILERS - REQUIREMENTS AND TEST METHODS |
CEN/TR 17103:2017 | Petroleum and related products - Fast pyrolysis bio-oils for stationary internal combustion engines - Quality determination |
ISO 3171:1988 | Petroleum liquids — Automatic pipeline sampling |
ISO 3170:2004 | Petroleum liquids — Manual sampling |
ISO 3679:2015 | Determination of flash no-flash and flash point — Rapid equilibrium closed cup method |
ISO 15528:2013 | Paints, varnishes and raw materials for paints and varnishes Sampling |
ISO 1513:2010 | Paints and varnishes Examination and preparation of test samples |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.