EN ISO 8253-3:2012
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Acoustics - Audiometric test methods - Part 3: Speech audiometry (ISO 8253-3:2012)
02-19-2022
03-01-2012
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements for recording of speech material
5 Validation of speech material recordings
6 Requirements for speech audiometry
7 Ambient sound pressure levels in test room for
speech audiometry
8 Sound field speech audiometry
9 Preparation and instruction of test subject
10 Subject's response mode
11 Determination of speech detection threshold level
12 Determination of speech recognition threshold level
13 Determination of speech recognition scores
14 Contralateral masking
15 Speech audiometry with competing sound
16 Format of speech audiogram
17 Measurement uncertainty
18 Maintenance and calibration of equipment
Annex A (informative) - Example of speech materials
Annex B (informative) - Examples of competing sound
conditions
Annex C (informative) - Typical results
Annex D (informative) - Optimization of perceptual balance
of test lists
Annex E (informative) - Measurement uncertainty
Bibliography
ISO 8253-3:2012 specifies basic methods for speech recognition tests for audiological applications.In order to ensure minimum requirements of precision and comparability between different test procedures including speech recognition tests in different languages, ISO 8253-3:2012 specifies requirements for the composition, validation and evaluation of speech test materials, and the realization of speech recognition tests. ISO 8253-3:2012 does not specify the contents of the speech material because of the variety of languages.Furthermore, ISO 8253-3:2012 also specifies the determination of reference values and fulfilment requirements for the realization and manner of presentation.ISO 8253-3:2012 specifies procedures and requirements for speech audiometry with the recorded test material being presented by air conduction through an earphone, or from a loudspeaker for sound field audiometry. Methods for using noise either for masking the non-test ear or as a competing sound are described.Some test subjects, for example children, can require amended test procedures not specified in ISO 8253-3:2012.Specialized tests such as those used for evaluating directional hearing and dichotic hearing are outside the scope of ISO 8253-3:2012.
Committee |
CEN/TC 211
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ONORM EN ISO 8253-3 : 2012 | Identical |
UNI EN ISO 8253-3 : 2012 | Identical |
I.S. EN ISO 8253-3:2012 | Identical |
ISO 8253-3:2012 | Identical |
PN EN ISO 8253-3 : 2012 | Identical |
BS EN ISO 8253-3:2012 | Identical |
NS EN ISO 8253-3 : 2012 | Identical |
UNE-EN ISO 8253-3:2012 | Identical |
NBN EN ISO 8253-3 : 2012 | Identical |
DIN EN ISO 8253-3:2012-08 | Identical |
NEN EN ISO 8253-3 : 2013 | Identical |
NF EN ISO 8253-3 : 2012 | Identical |
SN EN ISO 8253-3:2012 | Identical |
09/30198066 DC : 0 | BS EN 15927 - SERVICES OFFERED BY HEARING AID PROFESSIONALS |
NF EN 15927 : 2010 | SERVICES OFFERED BY HEARING AID PROFESSIONALS |
I.S. EN 15927:2010 | SERVICES OFFERED BY HEARING AID PROFESSIONALS |
UNI EN 15927 : 2010 | SERVICES OFFERED BY HEARING AID PROFESSIONALS |
EN 15927:2010 | Services offered by hearing aid professionals |
UNE-EN 15927:2011 | Services offered by hearing aid professionals |
CEI EN 60645-1 : 2016 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AUDIOMETRY |
BS EN 60645-1:2017 | Electroacoustics. Audiometric equipment Equipment for pure-tone and speech audiometry |
BS EN 15927:2010 | Services offered by hearing aid professionals |
I.S. EN 60645-1:2017 | ELECTROACOUSTICS - AUDIOMETRIC EQUIPMENT - PART 1: EQUIPMENT FOR PURE-TONE AND SPEECH AUDIOMETRY |
UNE-EN 60645-1:2015 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone audiometry |
EN 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
ISO 389-4:1994 | Acoustics Reference zero for the calibration of audiometric equipment Part 4: Reference levels for narrow-band masking noise |
IEC 60318-3:2014 | Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry |
ISO/TR 25417:2007 | Acoustics Definitions of basic quantities and terms |
ISO 266:1997 | Acoustics — Preferred frequencies |
IEC 60645-1:2017 | Electroacoustics - Audiometric equipment - Part 1: Equipment for pure-tone and speech audiometry |
IEC 60050-801:1994 | International Electrotechnical Vocabulary (IEV) - Part 801: Acoustics and electroacoustics |
ISO 389-1:1998 | Acoustics Reference zero for the calibration of audiometric equipment Part 1: Reference equivalent threshold sound pressure levels for pure tones and supra-aural earphones |
ISO 8253-1:2010 | Acoustics Audiometric test methods Part 1: Pure-tone air and bone conduction audiometry |
IEC 61260:1995 | Electroacoustics - Octave-band and fractional-octave-band filters |
IEC 60645-2:1993 | Audiometers - Part 2: Equipment for speech audiometry |
IEC 60318-1:2009 | Electroacoustics - Simulators of human head and ear - Part 1: Ear simulator for the measurement of supra-aural and circumaural earphones |
ISO 8253-2:2009 | Acoustics Audiometric test methods Part 2: Sound field audiometry with pure-tone and narrow-band test signals |
ISO/IEC Guide 98-3:2008 | Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995) |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.